Tecnoware EXA 1.1 Скачать руководство пользователя страница 7

ENGLISH 

UPS EXA 1.1-1.5-2.2-2.6-3.2 Rack Mount 

3

 

User’s manual 

 

2

 

General Characteristics 

EXA Rack Mount has all the advanced features, which guarantee maximum reliability and safety:  

 

All functions are controlled by a microprocessor, giving full guarantee of high reliability. 

 

Output Voltage regulation through AVR (Automatic Voltage Regulation). 

 

Overload protection both in normal mode and in battery mode. 

 

High performance battery charger, which extends the battery medium life ensuring an optimal recharge. 

 

Start up even if the electrical network is not available. 

 

Automatic restart after an automatic shut down due to a low battery condition once the AC utility power 
returns. 

 

Adapts automatically to 50 or 60 Hz input frequency. 

 

LCD  display  for  the  visualization  of  the  Input  and  Output  Voltage,  Battery  Level  percentage, Load Level 
percentage, functioning modes, alarm and fault conditions. 

 

Acoustic signals of various kinds indicating functioning modes and alarm/fault condition.  

 

Communication with the computer through RS-232 and USB interfaces. 

 

SNMP Adapter (optional). 

 

Protects and filters the telephone line. 

 

Fast swappable battery. 

 

High efficiency  

 

Maximum reliability  

 

Smart design and easy to use 

 
 

3

 

Receipt and site selection 

Carefully remove the UPS from its packaging, and carry out a meticulous inspection. We recommend keeping the 
original  packaging  in  a  secure  place,  in  case  you  need  to  send  the  UPS  for  maintenance  purposes.  In  case  of 
transport damage, notify the carrier and dealer immediately.  

We recommend paying attention to the below points in order to choose a correct placement for your UPS: 

 

The  UPS  is  designed  to  operate  in  a  protected  environment  (e.g.  offices).  We  therefore  recommend 
installing it in a place with very little or no humidity, dust or smoke.  

 

In  all  circumstances,  see  the  “Technical  Characteristics”  chapter  for  environmental  specifications  and 
check that the selected area meets these specifications. 

 

During normal operation the UPS discharges a minimal amount of heat. So it is necessary to leave at least 
20 cm of unobstructed space all around the UPS in order to keep it properly ventilated. 

 

Do not obstruct ventilation holes. 

 

Do not insert objects or pour liquids in the ventilation holes. 

 

Do not rest any object on top of the UPS. 

 

Do not keep liquids, flammable gases or corrosive substances near the unit.  

 

Install the UPS on a properly tiled floor. Avoid the installation on a floor that is not tiled flat. 

Содержание EXA 1.1

Страница 1: ...Uninterruptible Power Supply EXA 1 1 Rack Mount EXA 1 5 Rack Mount EXA 2 2 Rack Mount EXA 2 6 Rack Mount EXA 3 2 Rack Mount User s manual Manuale utente...

Страница 2: ......

Страница 3: ...acteristics 10 9 Maintenance 11 9 1 UPS Cleaning 11 9 2 Battery 11 9 3 Operator Safety 11 10 Troubleshooting 12 Conformity to the European Directives 13 Product Disposal 13 Lead Batteries 13 Copyright...

Страница 4: ...Funzionamento 21 6 1 Modo Normale 21 6 2 Modo Batteria 21 6 3 Fine Autonomia e Riaccensione Automatica 21 6 4 Controllo del Carico 21 6 5 Segnalazioni di Guasto 22 7 Interfacce di Comunicazione 22 8...

Страница 5: ...ponents are connected to the batteries they will remain powered and therefore dangerous even after the UPS has been disconnected from AC power mains Before any repair or maintenance work disconnect th...

Страница 6: ...condition directly to a computer this makes it possible to automatically save your data during an extended black out with the most widespread operating systems Windows Linux etc Read this manual caref...

Страница 7: ...pable battery High efficiency Maximum reliability Smart design and easy to use 3 Receipt and site selection Carefully remove the UPS from its packaging and carry out a meticulous inspection We recomme...

Страница 8: ...itions and measurements Front panel shown below consists of two parts 1 LCD display provides information about input only in line mode and output voltage output frequency only in battery mode battery...

Страница 9: ...voltage 3 BATTERY LEVEL 3 digits indicate the battery charging percentage 4 LOAD LEVEL 3 digits indicate the output load percentage 5 FREQUENCY the 3 digits indicate the output frequency only visualiz...

Страница 10: ...colour to supply critical loads 3 Telephone protection RJ11 IN OUT connectors to protect and filter a phone line TNV 3 type connections 4 Computer Interface DB9 female connector it is the communicatio...

Страница 11: ...onnected to the UPS outputs are working correctly By LCD display check if the Output load percentage is less than 100 otherwise it is necessary to remove part of the Output load 7 Simulate a black out...

Страница 12: ...by an acoustic signal every 10 seconds 6 3 Low Battery and Automatic Restart In Battery mode EXA Rack Mount indicates the Low Battery condition whenever the battery reaches a charge level allowing con...

Страница 13: ...Technical Characteristics as this may damage the unit In this case the warranty is void 6 5 Fault Condition The UPS indicates the Fault condition by LCD display by emitting a continuous acoustic alarm...

Страница 14: ...C Directive Efficiency 96 Battery Type Lead acid sealed free maintenance Number of batteries 2 3 Nominal Battery Voltage 24 Vdc 36 Vdc Battery Specifications 12 Vdc 7 Ah 6 cells 12 Vdc 7 Ah 6 cells 12...

Страница 15: ...procedure described in the chapter 5 before using it again Please keep in mind that the batteries must be recharged at least once a month Take in mind that batteries are recharged automatically if th...

Страница 16: ...positive pole of the battery ANOMALY POSSIBLE CAUSE ACTION TO SOLVE The UPS does not turn on ON OFF button Press the ON OFF button Batteries are flat Recharge the batteries for at least 4 hours Electr...

Страница 17: ...isposed as an urban waste but must be treated as a separate waste Any violation is indictable with financial sanctions as per in force regulations An incorrect waste disposal or an improper use of the...

Страница 18: ...ento l UPS e scollegato dalla rete elettrica le parti interne sono ancora in tensione essendo collegate alle batterie e quindi pericolose Prima di effettuare qualsiasi tipo di riparazione o manutenzio...

Страница 19: ...EXA Rack Mount perch contiene importanti avvisi di sicurezza per l operatore ed utili consigli per un corretto impiego Questo manuale una guida per installare e utilizzare correttamente l UPS Nel man...

Страница 20: ...o stato dell UPS In caso di danni dovuti al trasporto annotarli sulla bolla di accompagnamento merce e contattare subito il fornitore Si consiglia di conservare l imballo originale in luogo sicuro nel...

Страница 21: ...ale mostrato nella figura 1 costituito da 2 parti 1 Un display LCD che fornisce i valori della tensione d ingresso solo in modalit rete e d uscita la frequenza d uscita solo in modalit batteria la per...

Страница 22: ...lla tensione d uscita in volt 3 BATTERY LEVEL i 3 digit indicano la percentuale di carica delle batterie 4 LOAD LEVEL i 3 digit indicano la percentuale di potenza erogata in uscita 5 FREQUENCY i 3 dig...

Страница 23: ...tipo IEC C13 colore nero da utilizzare per alimentare carichi critici 3 Protezione Telefonica connettori RJ11 IN OUT per proteggere e filtrare una linea telefonica connessioni di tipo TNV 3 4 Interfac...

Страница 24: ...iano accesi regolarmente Inoltre controllare la percentuale di carico in Uscita indicata sul display LCD e assicurandosi che il valore sia inferiore al 100 altrimenti necessario rimuovere parte del ca...

Страница 25: ...le batterie sono scariche al punto da garantire soltanto alcuni minuti di autonomia L UPS avvisa l utente della condizione di Fine Autonomia emettendo un segnale acustico ogni secondo Se la linea ele...

Страница 26: ...ivi alimentati 7 Interfacce di Comunicazione L UPS dotato delle Interfacce RS232 e USB utilizzabili come porte di comunicazione con un Personal Computer Infatti sul retro sono presenti i connettori de...

Страница 27: ...iva Bassa Tensione CEI EN 62040 2 2006 Direttiva EMC Rendimento 96 Tipo Batterie Piombo acido sigillate senza manutenzione Numero di Batterie 2 3 Tensione Nominale Batterie 24 Vdc 36 Vdc Specifiche Ba...

Страница 28: ...a di riutilizzarlo normalmente svolgere la procedura di Prima Accensione descritta nell omonimo capitolo di questo manuale Tenere comunque presente che le batterie vanno ricaricate almeno 1 volta al m...

Страница 29: ...ANOMALIA POSSIBILE CAUSA AZIONI PER RISOLVERE L UPS non si accende Pulsante ON OFF Premere il pulsante ON OFF Batterie scariche Ricaricare le batterie per almeno 6 ore Guasto scheda elettronica Rivol...

Страница 30: ...ssere smaltito come rifiuto urbano ma deve esserlo tramite raccolta separata qualsiasi violazione punita con sanzioni pecuniarie ai sensi delle vigenti norme Lo smaltimento non corretto del prodotto o...

Страница 31: ......

Страница 32: ...TECNOWARE s r l www tecnoware com...

Отзывы: