Uninterruptible Power Supply 

 

EVO DSP PLUS MM 1.2 

EVO DSP PLUS MM 2.4 

EVO DSP PLUS MM 3.6 

 

 

User’s manual 

Manuale utente 

Содержание EVO DSP PLUS MM 1.2

Страница 1: ...Uninterruptible Power Supply EVO DSP PLUS MM 1 2 EVO DSP PLUS MM 2 4 EVO DSP PLUS MM 3 6 User s manual Manuale utente...

Страница 2: ...m 11 5 2 Rear Side 11 6 Electrical Installation 12 6 1 Installation 13 7 First Start Up 14 8 Functioning 15 8 1 Turning ON and OFF 15 8 2 Low Battery and Automatic Restart 15 8 3 Load Testing 16 8 4 S...

Страница 3: ...el authorized by producer TECNOWARE declines any responsibility if this warning is disregarded The electric installation has to be done by qualified personnel Follow all the Safety Standards CEI Stand...

Страница 4: ...DSP PLUS MM protects the devices from accidental overload or Inverter fault by an Automatic Bypass that directly connects the AC Input line with its outlets EVO DSP PLUS MM models are factory equipped...

Страница 5: ...s of all the UPS parameters by user through front panel pushbuttons and graphic LCD panel SNMP Adapter optional Communication with the computer through USB interfaces ECO functioning mode selectable F...

Страница 6: ...o leave at least 10 cm of unobstructed space all around the UPS in order to keep it properly ventilated Do not obstruct ventilation holes Do not insert objects or pour liquids in the ventilation holes...

Страница 7: ...if the UPS finds the Mains OFF condition due to a Blackout or Overvoltage Brownout it then switches into Battery mode In this case the batteries supply the required Output power thanks to the DC AC c...

Страница 8: ...mpletely off The Stand by mode is identified by The graphic LCD panel shows the path of energy flow during Stand by mode 4 5 ECO Mode It is possible to select the ECO mode to save energy and to increa...

Страница 9: ...quency by default the Converter Frequency mode is disable The Converter Frequency mode is identified by The graphic LCD panel shows the path of energy flow during Converter Frequency mode The CF chara...

Страница 10: ...DSP PLUS 1 2 2 4 3 6 MM 5 1 1 Graphic LCD Panel Please refer to figure 3 Figure 3 Graphic LCD Panel Battery Info Mode Operation Info Input Battery Voltage Info Output Voltage Info Load Info Backup Ti...

Страница 11: ...n Indicates that the UPS alarm is disabled muted Output Voltage information Indicates the Output Voltage or Frequency Vac Output Voltage Hz Output Frequency Load information Indicates the load level b...

Страница 12: ...for at least 5 seconds to perform the Battery Test while the UPS is in Normal mode SELECT Select the measurements on the graphic display by pressing the SELECT button it is possible to choose the ele...

Страница 13: ...n RJ11 RJ45 IN OUT connectors to protect and filter a phone line an ADSL or a LAN TNV 3 type connections 4 Grounded AC Input power socket IEC C14 type for EVO DSP PLUS 1 2 2 4 MM and IEC C20 type for...

Страница 14: ...t connections use ONLY the included power cables or cables with the same power ratings TECNOWARE declines any responsibility if this warning is disregarded The EVO DSP PLUS MM models are made of a sin...

Страница 15: ...se you to follow the steps below explained 1 Through the included power cable connect the UPS Input socket to the AC line outlet see figure 4 It is mandatory to ground the AC line outlet according to...

Страница 16: ...connected to the UPS outputs have the main switch in OFF position 2 Restore the AC Input line for the UPS be sure that the AC utility power is available and that its voltage and frequency are within t...

Страница 17: ...ss the OFF button If the ON button is pressed when AC Input line is not present the UPS switches ON even and works in Battery mode after some seconds If the OFF button is pressed when AC Input line is...

Страница 18: ...condition Do not connect a load greater than rated value to the UPS see POWER specifications in the chapter Technical Characteristics as this may damage the unit In this case the warranty is void 8 4...

Страница 19: ...ning condition the buzzer beeps once every second it means that there are some problems for UPS operation Users can get the Fault code from graphic LCD panel Please check the Troubleshooting chapter f...

Страница 20: ...circuit 14 Vdc Bus Under 03 None Battery Voltage too High 27 Vdc Bus Unbalance 04 None Battery Voltage too Low 28 Inverter Soft Start failure 11 None Over Temperature 41 None High Inverter Voltage 12...

Страница 21: ...imit come back to Line mode 290 Vac 5 Nominal Frequency 50 60 Hz automatic selection Frequency Range Normal mode 47 53 Hz 57 63 Hz Input Power Factor 0 99 at 100 Load OUTPUT Nominal Voltage Single Pha...

Страница 22: ...without Derating 3000 m Protection level IP 20 Cooling Fan cooling Audible Noise at 1 meter 45 dBA STANDARDS Safety EN 62040 1 1 EN 60950 1 Performance EN 62040 3 EMC EN 62040 2 category C2 Product c...

Страница 23: ...lly if the UPS is ON and working in Normal or in Bypass mode for after approximately 4 hours with AC Input line present Battery life strongly depends on the ambient temperature There are also other fa...

Страница 24: ...rviceable Any repair or maintenance work must be performed exclusively by qualified technical personnel authorized by TECNOWARE TECNOWARE declines any responsibility if this warning is disregarded SYM...

Страница 25: ...Fault code is shown as 14 the icon lights on LCD display and alarm beeps continuously The UPS shuts down automatically because short circuit occurs on the UPS Output Check Output wiring or if connect...

Страница 26: ...al or an improper use of the same or of any parts can be damaging for the environment and for human health A correct waste disposal of products having the dustbin symbol marked by a cross help to avoi...