User’s manual 

4

 

UPS ERA LED  0.65 – 0.85 – 1.1 

 

2

 

General Characteristics 

ERA LED has all the advanced features, which guarantee maximum reliability and safety:  

 

All functions are controlled by a microprocessor, giving full guarantee of high reliability. 

 

Output Voltage regulation through AVR (Automatic Voltage Regulation). 

 

Overload protection both in normal mode and in battery mode. 

 

High performance battery charger, which extends the battery medium life ensuring an optimal recharge. 

 

Start up even if the electrical network is not available. 

 

Automatic restart after an automatic shut down due to a low battery condition once the AC utility power 
returns. 

 

Adapts automatically to 50 or 60 Hz input frequency. 

 

Acoustic signals of various kinds indicating functioning modes and alarm/fault condition.  

 

Communication with the computer through USB interface. 

 

High efficiency  

 

Maximum reliability  

 

Smart design and easy to use 

 
 

3

 

Receipt and site selection 

Carefully remove the UPS from its packaging, and carry out a meticulous inspection. We recommend keeping the 
original  packaging  in  a  secure  place,  in  case  you  need  to  send  the  UPS  for  maintenance  purposes.  In  case  of 
transport damage, notify the carrier and dealer immediately.  

We recommend paying attention to the below points in order to choose a correct placement for your UPS: 

 

The  UPS  is  designed  to  operate  in  a  protected  environment  (e.g.  offices).  We  therefore  recommend 
installing it in a place with very little or no humidity, dust or smoke.  

 

In  all  circumstances,  see  the  “Technical  Characteristics”  chapter  for  environmental  specifications  and 
check that the selected area meets these specifications. 

 

During normal operation the UPS discharges a minimal amount of heat. So it is necessary to leave at least 
20 cm of unobstructed space all around the UPS in order to keep it properly ventilated. 

 

Do not obstruct ventilation holes. 

 

Do not insert objects or pour liquids in the ventilation holes. 

 

Do not rest any object on top of the UPS. 

 

Do not keep liquids, flammable gases or corrosive substances near the unit.  

 

Install the UPS on a properly tiled floor. Avoid the installation on a floor that is not tiled flat. 

Содержание ERA LED 0.65

Страница 1: ...Uninterruptible Power Supply ERA LED 0 65 ERA LED 0 85 ERA LED 1 1 User s manual ...

Страница 2: ......

Страница 3: ...ics 10 9 Maintenance 11 9 1 UPS Cleaning 11 9 2 Battery 11 9 3 Battery Replacement 11 9 4 Operator Safety 12 10 Troubleshooting 12 Conformity to the European Directives 14 Product Disposal 14 Lead Batteries 14 Copyright 2012 TECNOWARE s r l All rights reserved All trademarks are property of their respective owners TECNOWARE s r l Via Montetrini 2E Loc Molino del Piano 50065 Pontassieve FI Italy ww...

Страница 4: ... the batteries they will remain powered and therefore dangerous even after the UPS has been disconnected from AC power mains Before any repair or maintenance work disconnect the batteries by removing the positive cable red colour from the positive pole of the battery It is compulsory to ground the UPS according to Safety Standards The AC mains power supply socket used to power the UPS must have an...

Страница 5: ...r a low battery condition directly to a computer this makes it possible to automatically save your data during an extended black out with the most widespread operating systems Windows Mac OS X Linux etc Read this manual carefully before using the ERA LED it includes important safety warnings and useful advices for correct use and installation This manual is a guide that enables you to correctly in...

Страница 6: ... packaging and carry out a meticulous inspection We recommend keeping the original packaging in a secure place in case you need to send the UPS for maintenance purposes In case of transport damage notify the carrier and dealer immediately We recommend paying attention to the below points in order to choose a correct placement for your UPS The UPS is designed to operate in a protected environment e...

Страница 7: ...and measurements Front panel shown below consists of two parts 1 The ON OFF button enables the user to turn ON OFF the UPS 2 The LINE BATTERY led this led blue color is always on during the functioning in Normal Mode it flashes one time every 4 seconds in Battery mode and it flashes one time every second in Low Battery condition Figure 1 Front panel 2 1 ...

Страница 8: ...t fuse electrical specification max current 5 A voltage 250 V 3 Grounded UPS Output receptacles IEC C13 type black colour to supply critical loads 4 Computer Interface USB connector it is the communication USB port In case of anomaly to the AC line black out the UPS Output receptacles black colour 3 continue supplying the correct power to all connected equipment 1 3 2 4 ...

Страница 9: ...sure that all the devices connected to the UPS outputs are working correctly 7 Simulate a black out by removing the AC Input line The UPS starts working in Battery mode the UPS emits a brief acoustic signal every 10 seconds 8 Be sure that all the devices connected to the UPS outputs are working correctly and the UPS doesn t signal any sort of anomaly 9 Restore the AC Input line after few seconds t...

Страница 10: ... 10 seconds and simultaneously the LINE BATTERY led flashes 6 3 Low Battery and Automatic Restart In Battery mode ERA LED indicates the Low Battery condition whenever the battery reaches a charge level allowing connected devices to operate for approximately one more minute During Low Battery condition the UPS emits an acoustic alarm signal every second and simultaneously the LINE BATTERY led flash...

Страница 11: ...han rated value to the UPS see POWER specifications in the chapter Technical Characteristics as this may damage the unit In this case the warranty is void 6 5 Fault Condition The UPS indicates the Fault condition by emitting a continuous acoustic alarm During Fault condition the UPS doesn t supply Output power and so all the supplied devices are switched off 7 Communication Interface The UPS is fa...

Страница 12: ...attery mode 5 Output Inverter Waveform Modified Sinewave Accepted Overload 130 Certifications CE Standards CEI EN 62040 1 2009 Low Voltage Directive CEI EN 62040 2 2006 EMC Directive Efficiency 92 Battery Type Lead acid sealed free maintenance Number of batteries 1 Nominal Battery Voltage 12 Vdc Battery Specifications 12 Vdc 4 5 Ah 6 cells 12 Vdc 7 2 Ah 6 cells 12 Vdc 9 Ah 6 cells Backup Time typi...

Страница 13: ...th Take in mind that batteries are recharged automatically if the UPS works in Normal mode or if the UPS is off and connected to the AC Input Line Battery life strongly depends on the ambient temperature There are also other factors like the number of charge discharge cycles the discharge depth humidity and altitude The recommended environmental specifications for a correct use of batteries are li...

Страница 14: ...Do not dispose of batteries in a fire The batteries may explode CAUTION Do not open or mutilate batteries Released electrolyte is harmful to the skin and eyes It may be toxic 9 4 Operator Safety Whenever the UPS is not responding anymore to original characteristics the UPS must be made non operative and every usage not authorised must be avoided After it will be necessary to refer to qualified tec...

Страница 15: ...board failure Refer to Technical Service The UPS always function on Battery mode Input mains power cable is disconnected Check the input mains power cable Check the presence of the electrical mains Input mains fuse is burnt Replace the fuse with another of the same type Black out conditions surge Over Voltage or Low Voltage Wait until the AC Input Line returns to normal conditions Electronic board...

Страница 16: ... urban waste but must be treated as a separate waste Any violation is indictable with financial sanctions as per in force regulations An incorrect waste disposal or an improper use of the same or of any parts can be damaging for the environment and for human health A correct waste disposal of products having the dustbin symbol marked by a cross help to avoid negative consequences to the environmen...

Страница 17: ......

Страница 18: ......

Страница 19: ...TECNOWARE s r l www tecnoware com ...

Отзывы: