DESCRIPTION 

 

WP10EX 

stainless  steel  Pressurized  Washer  System  with  integral  solenoid  valve  has  been  developed  to  be  used  with 

CCTV cameras in industrial, marine and highly corrosive environments. The washer system supplied pairs preferably with 
Tecnovideo  camera  housings  or  alternatively  with  housings  which  haven't  washer  facility.  The  fluid  tank  is  a  10  litre 
manually  pressurized  unit  with  built  in  pressure  gauge.  Solenoid's  control  voltage  to  be  connected  to  the  solenoid's 
terminal  box  through  suitable  power  cables.  An  AISI316L  stainless  steel  compact  cabinet  protects  the  unit  from  the 
environmental agents. 

 

MODELS 

 

 

WP10EXe/24

 

24 VUC supply voltage. EX II 2G Ex e mb IIC Gb T4, II 2D Ex t IIIC Db IP67 T=135°C 

WP10EXe/110

 

110 V~ supply voltage. EX II 2G Ex e mb IIC Gb T4, II 2D Ex t IIIC Db IP67 T=135°C 

WP10EXe/230

 

230 V~ supply voltage. EX II 2G Ex e mb IIC Gb T4, II 2D Ex t IIIC Db IP67 T=135°C 

WP10EXd/24

1

 

24 V~ supply voltage. EX II 2G Ex d IIC Gb T6, II 2D Ex tb IIIC Db IP66/67 

WP10EXd/110

1

  110 V~ supply voltage. EX II 2G Ex d IIC Gb T6, II 2D Ex tb IIIC Db IP66/67 

WP10EXd/230

1

  230 V~ supply voltage. EX II 2G Ex d IIC Gb T6, II 2D Ex tb IIIC Db IP66/67 

 

1

 

½” NPT Nickel-plated brass cable gland (EX II 2 G Ex d IIC, II 2 D Ex tD IP68) for armoured cable (O.D. 8,5 to 16mm, I.D. 6 to 12mm) included. 

 

CERTIFICATIONS 

 

Ingress Protection(EN 60529) 

Solenoid valve: IP67 (WP10EXe models) / IP66/IP67 (WP10EXd models) 

 

 

 

 

Cabinet: not rated 

Rating (WP10EXe models) 

     II 2G Ex e mb IIC Gb T4 /     II 2D Ex t IIIC Db IP67 

Rating (WP10EXd models) 

     II 2G Ex d IIC Gb T6 / 

II 2D Ex tb IIIC Db IP66/67 

EMC 

 

 

 

EN 61000-6-3:2007; EN 50130-4:1995 + A1:1998 + A2:2003 

LVD 

 

 

 

EN 60950-1:2006 + A11:2009 

RoHS 

 

 

 

2011/65/EU 

WEEE 

 

 

 

2012/19/EU 

 

PRELIMINARY REMARKS 

 

Prior  to  installation  and  operation,  read  carefully  all  instructions  in  this  manual  and  in  the  solenoid  valve  installation 
manual. Heed all warnings. 

Unpack this equipment and handle it carefully. If the package appears to be damaged, notify the shipper immediately. 

Use  the  original  packaging  to  transport  the  unit.  Disconnect  power  supply  before  moving  it.  In  case  of  returning  the 
equipment, the original packaging must be used. 

Make  sure  that  the  installation  surface  can  support  at  least  four  times  the  weight  of  the  unit  in  normal  operating 
conditions. In case of excessive external stress (e.g. vibration, strong winds or impact), the equipment may need additional 
means of protection. 

Proper stainless steel hardware should be carefully chosen to fasten the unit to the surfaces. 

Use  caution  when  lifting  and  assembling  the  unit.  It  is  recommended  that  non-slip  protective  gloves  be  worn  during 
installation. The unit could bear sharp edges. 

Keep the unit empty until the end of the installation. 

The  unit  is  intended  to  be  used  with  water  or  with  water  solutions:  denser  mixtures  could  obstruct  the  nozzle.  If  the 
solution used has residual, it must be filtered before use.

 

Do not use inflammable liquids, hydrogen peroxide (nor similar 

substances  that  give  off  oxygen),  corrosive  substances,  liquids  containing  ammonia,  solvents  and  liquids  containing 
solvents, viscous or greasy liquids, liquids that form residues (dyes and greases). 

The safety valve must not be bypassed or made inoperative. 

Observe the legal requirements of your country for accident prevention and check the tank regularly. 

Stainless steel reservoir: keep the O-rings, the safety valve and the internal of the tank clean. When opening/closing the 
reservoir, pay attention to the correct placement of the O-rings in their seatings. 

Use  appropriate  tools  for  the  purpose.  The  particular  nature  of  the  site  where  the  device  is  to  be  installed  may  require 
special  tools  for  installation.  Tightening/loosing  the  screws  using  automatic  tools  such  as  drill  drivers  may  result  in 
damaged threads. 

 

 

3

 

 

Содержание WP10EX Series

Страница 1: ...WP10EX Pressurized Washer System with integral solenoid valve Installation manual Issue 20200115...

Страница 2: ...IMINARY REMARKS 03 INSTALLING THE UNIT 05 Opening the washer system 05 Electrical connections 05 WP10EXe connection diagram 05 WP10EXd connection diagram 05 Passing the cables 05 USAGE 06 Filling the...

Страница 3: ...his manual and in the solenoid valve installation manual Heed all warnings Unpack this equipment and handle it carefully If the package appears to be damaged notify the shipper immediately Use the ori...

Страница 4: ...n all the cables inside the housing with cables ties or other fixing means to avoid the electrical contact with surrounding parts in case that terminal blocks screw off Electrical connections such as...

Страница 5: ...nnection must be performed via the solenoid valve cable gland included Check the valve label for the correct supply voltage When supply voltage is provided the solenoid valve will open letting the wat...

Страница 6: ...it is needed to restore the internal pressure Eventually close the cabinet Maintenance and filter replacement This equipment has been designed to fit in harsh environments requiring little or no maint...

Страница 7: ...ELECTRICAL DIAGRAM In the diagram below it is shown how to control WP10EX Series washer systems via a Dry Contact Relay input To do so it is needed the DCI EXWP interface sold separately 7...

Страница 8: ...For more information about collection and recycling of old products please contact your local municipality or your waste disposal service Penalties may be applicable for incorrect disposal of this wa...

Отзывы: