![TecnoVideo WP10EX Series Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/tecnovideo/wp10ex-series/wp10ex-series_installation-manual_1072286003.webp)
DESCRIPTION
WP10EX
stainless steel Pressurized Washer System with integral solenoid valve has been developed to be used with
CCTV cameras in industrial, marine and highly corrosive environments. The washer system supplied pairs preferably with
Tecnovideo camera housings or alternatively with housings which haven't washer facility. The fluid tank is a 10 litre
manually pressurized unit with built in pressure gauge. Solenoid's control voltage to be connected to the solenoid's
terminal box through suitable power cables. An AISI316L stainless steel compact cabinet protects the unit from the
environmental agents.
MODELS
WP10EXe/24
24 VUC supply voltage. EX II 2G Ex e mb IIC Gb T4, II 2D Ex t IIIC Db IP67 T=135°C
WP10EXe/110
110 V~ supply voltage. EX II 2G Ex e mb IIC Gb T4, II 2D Ex t IIIC Db IP67 T=135°C
WP10EXe/230
230 V~ supply voltage. EX II 2G Ex e mb IIC Gb T4, II 2D Ex t IIIC Db IP67 T=135°C
WP10EXd/24
1
24 V~ supply voltage. EX II 2G Ex d IIC Gb T6, II 2D Ex tb IIIC Db IP66/67
WP10EXd/110
1
110 V~ supply voltage. EX II 2G Ex d IIC Gb T6, II 2D Ex tb IIIC Db IP66/67
WP10EXd/230
1
230 V~ supply voltage. EX II 2G Ex d IIC Gb T6, II 2D Ex tb IIIC Db IP66/67
1
½” NPT Nickel-plated brass cable gland (EX II 2 G Ex d IIC, II 2 D Ex tD IP68) for armoured cable (O.D. 8,5 to 16mm, I.D. 6 to 12mm) included.
CERTIFICATIONS
Ingress Protection(EN 60529)
Solenoid valve: IP67 (WP10EXe models) / IP66/IP67 (WP10EXd models)
Cabinet: not rated
Rating (WP10EXe models)
II 2G Ex e mb IIC Gb T4 / II 2D Ex t IIIC Db IP67
Rating (WP10EXd models)
II 2G Ex d IIC Gb T6 /
II 2D Ex tb IIIC Db IP66/67
EMC
EN 61000-6-3:2007; EN 50130-4:1995 + A1:1998 + A2:2003
LVD
EN 60950-1:2006 + A11:2009
RoHS
2011/65/EU
WEEE
2012/19/EU
PRELIMINARY REMARKS
i
Prior to installation and operation, read carefully all instructions in this manual and in the solenoid valve installation
manual. Heed all warnings.
Unpack this equipment and handle it carefully. If the package appears to be damaged, notify the shipper immediately.
Use the original packaging to transport the unit. Disconnect power supply before moving it. In case of returning the
equipment, the original packaging must be used.
Make sure that the installation surface can support at least four times the weight of the unit in normal operating
conditions. In case of excessive external stress (e.g. vibration, strong winds or impact), the equipment may need additional
means of protection.
Proper stainless steel hardware should be carefully chosen to fasten the unit to the surfaces.
Use caution when lifting and assembling the unit. It is recommended that non-slip protective gloves be worn during
installation. The unit could bear sharp edges.
Keep the unit empty until the end of the installation.
The unit is intended to be used with water or with water solutions: denser mixtures could obstruct the nozzle. If the
solution used has residual, it must be filtered before use.
Do not use inflammable liquids, hydrogen peroxide (nor similar
substances that give off oxygen), corrosive substances, liquids containing ammonia, solvents and liquids containing
solvents, viscous or greasy liquids, liquids that form residues (dyes and greases).
The safety valve must not be bypassed or made inoperative.
Observe the legal requirements of your country for accident prevention and check the tank regularly.
Stainless steel reservoir: keep the O-rings, the safety valve and the internal of the tank clean. When opening/closing the
reservoir, pay attention to the correct placement of the O-rings in their seatings.
Use appropriate tools for the purpose. The particular nature of the site where the device is to be installed may require
special tools for installation. Tightening/loosing the screws using automatic tools such as drill drivers may result in
damaged threads.
3