MAINTENANCE 

 

Please read and be familiar with the following instructions before servicing the unit. 

Ensure proper operating condition of the unit performing safety checks upon completion of maintenance. 

Disconnect the unit from the supply circuit before cleaning. Do not use caustic or abrasive cleaning products. 

Use only replacement parts specified by the manufacturer. 

Inspection and maintenance of the equipment must be carried out in accordance with the applicable standards (i.e. EN 
60079-17). Repair of the equipment must be carried out in accordance with the applicable standards (i.e. EN 60079-19). 

Disconnect  the  unit  from  the  supply  circuit  and  report  to  qualified  service  personnel  whenever  any  damage  to  the 
equipment has been detected. 

Do not use electrical equipment that seem worn or old. 

 

This equipment has been designed to fit in harsh environments requiring little or no maintenance. Suggested inspection interval is 6 
months, but extremely harsh environments may require more frequent inspection and maintenance checks. On each inspection check 
the O-ring seals and the window wiper blade. Replace them if necessary. On each inspection check the drive motors and the adequate 
lubrication/greasing of the gears. Apply lubricant/grease if necessary. 

 

Regularly perform the following routine activities: 

- Clean the glass: use water or a liquid detergent that will not generate a hazardous situation. 
- Clean the germanium window: remove the protective guard unscrewing the 3 screws using a no sparking hex wrench. Use water or a 

liquid detergent that will not generate a hazardous situation. Be careful not to scratch the carbon coating. Using ethyl alcohol, 
solvents, hydrogenated hydrocarbons, strong acids or alkalis will irreparably damage the germanium window. Once completed 
the cleaning, properly reassemble the protective guard. 

- Clean the unit: the layer of filth upon the unit should never exceed 5mm thick. Use a dry or damp cloth. Do not use compressed air. 
- Check electrical connections: check cables and electrical connections for integrity and tightness. If the cables seem wore or damaged, 

refer to the extraordinary maintenance section. 

-  Check  mounting  accessories:  check  mounting  bolts  and  screws  for  integrity  and  tightness.  Replace  or  tighten  any  damaged/loose 

mounting hardware. 

 

Extraordinary maintenance: 

Any intervention which is not listed in the routine activities list must be done in absence of potentially explosive atmosphere. 
Any repair or replacement must be done by, or under supervision of, Tecnovideo. Use only original spare parts. 
The manufacturer declines all liability for any damage resulting from tampering, use of non-original spare parts and service carried out 
without following the directives of the present manual. 

 

If  the  equipment  is  likely  to  come  into  contact  with  aggressive  substances,  then  it  is  the  responsibility  of  the  user  to  take  suitable 
precautions that prevent it from being adversely affected, thus ensuring that the type of protection is not compromised. 
Aggressive substances: acidic liquids or gases that may attack metals, or solvents that may affect polymeric materials. 
Suitable precautions: regular checks as part of routine inspections or establishing from the material’s data sheet that it is resistant to 
specific chemicals. 

 

TECHNICAL DATA 

 

General & Mechanical  

Construction: 

 

AISI316L Stainless Steel 

Finish: 

 

 

Electro-polished 

Pan: 

 

 

Angle:

 350° (+/- 175° or continuous rotation); 

Speed:

 0 – 36°/second; 

Torque:

  80 Nm 

Tilt: 

 

 

Angle:

 180° (+/- 90°); 

Speed:

 0 – 18°/second; 

Torque:

  107 Nm 

Maximum load:  

 

25kg 

Cable entries:  

 

1x M25x1,5 cable entry 

 

Electrical 

Thermostatically controlled Heater:  T[°C] ON = 12 ± 4°C, T[°C] OFF = 20 ± 3°C 
Supply voltage: 

 

 

24, 115, 230V~ (specified at order) 

Power consumption:  

 

95W MAX (120W MAX for EXPTZD) 

 

Certifications  

Weatherproof standard:  

IP66/IP67 

Rating:   

  

II 2 G Ex db op pr IIC T6 Gb -40°C ≤ Tamb ≤ +60°C 

 

 

 

II 2 D Ex tb IIIC T85°C Db -40°C ≤ Tamb ≤ +60°C 

 

 

 

II 2 G Ex db op pr IIB T5 Gb -40°C ≤ Tamb ≤ +75°C 

 

 

 

II 2 D Ex tb IIIC T100°C Db -40°C ≤ Tamb ≤ +75°C 

ATEX Standards:    

EN 60079-0:2012; EN 60079-1:2014; EN 60079-28:2015; EN 60079-31:2014 

IECEx Standards:    

IEC 60079-0:2011; IEC 60079-1:2014-06; IEC 60079-28:2015; IEC 60079-31:2013 

CE compliant 
 

Содержание EX129 Series

Страница 1: ...EXPTZ Series Hazardous Area PTZ Camera Station Installation manual Issue 20200115...

Страница 2: ...lable on CR versions only 07 Password and reset button available on CR versions only 07 Default limits 07 Changing the default limits 07 Preset 07 Special auxiliary functions available on CR versions...

Страница 3: ...ing it In case of returning the equipment the original packaging must be used Any change performed on the unit that is not previously approved by the manufacturer will void both the certification and...

Страница 4: ...case is properly earthed connecting all the earth ground studs b Do not connect the unit to a supply circuit unless the installation is completed Check the proper position of the O ring seals in their...

Страница 5: ...ug in connector is different in shape and or colour to avoid any wrong connection The connections should be performed according to the below Field installation ID Name Notes M1 Supply voltage Dependin...

Страница 6: ...me Fuse value F1 10 A T 250 VAC 5x20 F2 10 A T 250 VAC 5x20 230 VAC supply voltage Fuse name Fuse value F1 6 3 A T 250 VAC 5x20 F2 10 A T 250 VAC 5x20 All the fuse must be T type time lag Different su...

Страница 7: ...set from 1 to 69 and from 100 to 150 can be used to set call specific positions The other presets are factory reserved and cannot be used to set call specific positions On the first command received t...

Страница 8: ...tch 1 is referred to the least significant digit 20 while switch 8 is referred to the most significant digit 27 For example the address 13 00001101 inbinary canbe set upturning ON the switch1 3and 4 s...

Страница 9: ...ck electrical connections check cables and electrical connections for integrity and tightness If the cables seem wore or damaged refer to the extraordinary maintenance section Check mounting accessori...

Страница 10: ...description of the unit such as camera housing P T unit MODEL model name of the unit such as EX129 EXPTZ S N Tecnovideo serial number followed by the year of manufacturing VOLTAGE supply voltage of t...

Страница 11: ...11...

Страница 12: ...able for incorrect disposal of this waste in accordance with national legislation The manufacturer declines all liability for any consequence resulting from improper installation practices tampering o...

Отзывы: