Installing Batteries

1. Remove the battery compartment door located on the bottom of the instrument by sliding up, as shown 

below. Install batteries,Postive Polarity outwards (towards battery door ).(See fig 2).

Power Indication/ Battery Test The TSCE-J1 :provides two indications of battery voltage status; a Con- stant Power 

indicator (leftmost LED )and a Battery Test function. The Constant Power indicator allows the user to see the 

battery level at all times. The LED will remain on whenever the unit is powered on.lt may appear as one of three 

colors (See Fig.3): 

GREEN- 

RANGE-

Battery voltage is normal and,Sufficient for proper operation.

Battery voltage is approaching the lower threshold for operation, replace as soon as possible.

Battery voltage is below acceptable operating level.

RED-

GETTING STARTED

OPERATING FEATURES

Содержание TSCE-J1

Страница 1: ...AUTOMATIC REFRIGERANT LEAK DETECTORTSCE J1 COD 11132033 Owner s Manual Rev 01 2013...

Страница 2: ...ral information 3 Features 3 Parts Controls 4 Getting Started 5 Installing Batteries 5 Operating Features 6 Operating Instructions 7 Operating Features 8 Applications 9 Maintenance 9 Specifications 10...

Страница 3: ...level 1 to level 7 Unique Tri Color LEDs show a progressive and wide ranging leak size indication communicate the sensitivity level and provide a true voltage indication of battery power level A tact...

Страница 4: ...4 PARTS CONTROLS 1 SensingTip 2 TipProtector 3 PowerON OFF 4 ResetButton 5 SensitivityUp 6 SensitivityDown 7 LED Leak Indicators 8 FlexibleProbe B C I...

Страница 5: ...ower indicator leftmost LED and a Battery Test function The Constant Power indicator allows the user to see the battery level at all times The LED will remain on whenever the unit is powered on lt may...

Страница 6: ...J1 provides seven levels of sensitivity the sensitivity level is indicated on the visual display when either the SENSITVITY OR SENSITIVITY keys are pressed The base beeping tone is also an indication...

Страница 7: ...ey This adjustment will not interrupt detection 6 If a full alarm occurs before the leak is pinpointed press the RESET key to reset the circuit to a zero reference as described above OPERATINGTIPS The...

Страница 8: ...At each area checked the probe should be moved around the location at a rate no more than 25 to 50mm second 1 2in second And no more than 5mm 1 4in from the surface completely around the position Slo...

Страница 9: ...nsing tip clean Prevent dust moisture and grease build up by utilizing the provided tip protector Never use the unit without the protector in place Before using the unit always inspect the tip and pro...

Страница 10: ...0 1 oz yr 3gr yr for all Halogen based refrigerant SensingTip Life Approx 20 hours OperatingTemperatur 30 to 125 F 0 to 52 C Battery Life Approximately 30 hours normal use Duty Cycle Continuous no lim...

Отзывы: