![Tecnosystemi Toolsplit 11131043 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/tecnosystemi/toolsplit-11131043/toolsplit-11131043_user-manual_1072164007.webp)
The vacuum gauge is suitable for air-conditioners, medical equipments, food storage equipments, vacuum pumps, etc...
APPLICATION
TECHNICAL PARAMETERS
Joint type
standard 1/4” male flare fitting
Display Units
microns, torr, bar, kpa, bar, psi, Kgf/cm2, mmHg, inHg, psi
Measuring range
0 to - 30 PSI
Applicable Temperature Range
- 20 to 80°C
Overloading pressure
40 PSI
Accuracy
0,01KPA
Stability
1%
Size
80mm
Power
9V
FUNCTION FEATURES
1.
Battery life: 60 hours continuous working do not affect the accuracy of the measurement. When the battery is running
out (under 6V), an indicator will appear on the display requesting the substitution of the battery.
2.
Auto power-off: when the instrument is not used, the display light is turned off after 10 minutes. The instrument
automatically turns off after 45 minutes if not used.
3.
Thermostat facility: the vacuum gauge is equipped with a temperature sensor for the protection of the electrical
circuits. When it indicates 0-50°C it carries out temperature drift.
BEFORE MEASURING
1.
VERIFY THE BATTERY STATUS.
2.
MAKE SURE THAT ALL JUCTIONS ARE WELL CLOSED AND
THERE ARE NO LEAKAGES.
7