11.  Posizionare le mensole della staffa in posizione orizzontale e abbassare la macchina fino a farla appoggiare 

sulla staffa; (vedi foto 7) procedendo poi con il fissaggio della motocondensante mediante gli antivibranti con 

viti in dotazione. ATTENZIONE! Prima di staccare il paranco dall’unità esterna assicurarsi che la stessa sia 

fissata correttamente alla staffa mediante le viti in dotazione.

12.  Per lo smontaggio del sollevatore eseguire le operazioni in senso inverso.

1. 

Before fixing the bracket to the wall, insert the 2 threaded small plates into the recess of the bar on the wall level with 

slots “x” and “y” (see fig.1)

2. 

Now insert part “D” into part “A” vertically (photograph 5). Now put part “A” onto the bracket’s bar moving from high 

to low (photograph 2) inserting the 2 coupling teeth into the two appropriate holes you will see above the slots. At this 

point part “A” is only attached to the bracket (photograph 3).

3. 

To secure part “A” to the bracket, use the 2 black knobs supplied, tightening them onto the threaded small plates that 

you must first position behind the bar on the wall. (see fig.4)

4. 

Now position part “B” into part “D” horizontally. Remember also to always to insert the dedicated safety pins to keep 

parts “A”, “B” and “D” safely coupled.

5. 

Adjust the hoist’s levelling with the 4 adjustment knobs at the ends of part “A”, so that all 4 press lightly against the 

masonry. Check the system is correct and firm before attempting lifting. Before turning on the machine, make sure it 

is perfectly stable and secured.

6. 

Power the motor from a 220 volt socket. 

7. 

Position the bar (part “C”) above the condenser unit, (see fig. 6), secure the machine to the bar bar using the 2 straps 

(supplied). (on how to secure the straps, see the enclosed instructions). ATTENTION! The straps must pass inside the 

machine’s feet to stop them from sliding outwards.

8. 

To perform a first trial lift, use the control pushbutton. To lift the load, on the pushbutton panel, press down 

the lifting switch (and keep it pressed); to lower the load, click the lowering switch of the pushbutton panel 

and keep it pressed; the hoist stops, releasing the push-buttons or, automatically, when it reaches maximum-lift height. 

Lift the outdoor unit a few centimetres. Now check that the machine is perfectly stable; if the machine is not level, 

slide the eyelet-hook along the slot of part “C” until it is perfectly level. Check that, during lifting, the metal cable winds 

around the full length of the drum. ATTENTION! Stand clear of suspended loads.

9. 

Lift up the machine until the base of the unit external meets or is higher than the position for shelves-securing.

10.  Position the shelves of the bracket horizontally and lower the machine to make it rest on the bracket; (see photograph 

7) now fasten the condenser unit with the screws supplied. ATTENTION! Before separating the hoist from the outdoor 

unit, make sure that the unit is fixed correctly to the bracket with the screws supplied.

11.  To disassemble the lift, perform the operations in reverse order.

1

2

Posizionamento piastrine filettate all’interno della barra 

reggi mensola in corrispondenza delle asole “x” e “y”. 

/ Positioning the threaded small plates within the shelf-

support bar level with slots “x” and “y”.

Posizionamento particolare “A” sulla barra reggi mensola.

/ Positioning part “A” on the shelf-support bar.

Содержание smart clima 11100200

Страница 1: ...neto Treviso Italy Phone 39 0438 500044 Fax 39 0438 501516 Numero Verde 800 904474 only for Italy email info tecnosystemi com C F P IVA R I TV IT02535780247 Cap Soc 5 000 000 00 i v REV 07 21 07 2022...

Страница 2: ...sotto del carico sospeso avendo cura di tenere una posizione laterale alle due staffe e mai per nessun motivo centrale ATTENZIONE Prima di effettuare qualsiasi operazione di sollevamento assicurarsi...

Страница 3: ...posti W e Q vedi foto A svitandole dalla posizione originale e fissandole al nuovo punto di ancoraggio In questo modo si riduce notevolmente l ingombro del sollevatore nella parte superiore permettend...

Страница 4: ...ilit e fissaggio della macchina 7 Alimentare il motore mediante la presa a 220 volt 8 Posizionare la barra particolare C sopra la motocondensante vedi fig 6 fissare la macchina alla barra mediante le...

Страница 5: ...ocket 7 Position the bar part C above the condenser unit see fig 6 secure the machine to the bar bar using the 2 straps supplied on how to secure the straps see the enclosed instructions ATTENTION The...

Страница 6: ...xing part A to the shelf support bar with the black knobs supplied 3 5 6 4 Inserimento del particolare B sul particolare A Adding part B to part A Fissaggio barra particolare C all unit esterna con le...

Страница 7: ...di danni La garanzia non copre la sostituzione dei componenti che risultano danneggiati per trasporto non idoneo installazione non conforme a quanto specificato in questo manuale di installazione uso...

Страница 8: ...i com via dell Industria 2 4 Z I San Giacomo di Veglia 31029 Vittorio Veneto Treviso Italia Tel 39 0438 500044 Fax 39 0438 501516 email info tecnosystemi com C F P IVA R I TV IT02535780247 Cap Soc 5 0...

Отзывы: