9. PROCEDURE FOR MANAGING MASTER CHRONO-THERMOSTAT 

ERRORS

When one of the LEM RF room probes detects a problem on its zone, the master chrono-

thermostat will display error E8 (generic). You must access the master chrono-thermostat to 

check which zone has triggered the alarm and check what kind of alarm it is.

Procedure from the MASTER chrono-thermostat. 

With the chrono-thermostat switched on and unlocked, proceed as follows:

a) Press the SET button for 3 seconds to access the Master chrono-thermostat sub-menu;

b) Press the SET button 9 times until “ZONE” flashes at the bottom in the centre.

c) Press the send button, checking that 01 is displayed in the centre;

d) Press the + or - buttons to select the desired zone: press the send button to confirm. 

The MASTER chrono-thermostat will now display the parameters for the selected zone and 

allow you to change the settings in the same way as a normal Discovery 2X zone chrono-

thermostat (refer to the master chrono-thermostat instructions in the system manual). 

The number of the selected zone will flash in the centre at the bottom (e.g. ZONE “3”). If 

no changes are made or no buttons pressed on the master chrono-thermostat within 60 

seconds, it will exit the control for the selected zone and return to the Master zone (ZONE 1).

Once the checks or parameter changes have been completed, the following operations can 

be performed;

•  Display another system zone with the same procedure outlined in point 5.

•  Return to control of ZONE 1 MASTER: exit due to time-out.

When the batteries run out, the LEM RF room probe switches off: the warning message will 

appear on the following devices:

•  a) Master chrono-thermostat with Error E8 (generic). Skip to point “PROCEDURE FOR 

MANAGING MASTER CHRONO-THERMOSTAT ERRORS” to manage the settings and 

errors from the system master chrono-thermostat.

•  b) On the Polaris 3X control panel by the flashing of the thermostat affected (e.g. T3 for 

zone 3);

•  c) On the Proair Multizone App if the system is configured on the App, with error E0 - 

“Communication error”

Replace the old batteries with two new ones: when the batteries are inserted, the LEM RF 

room probe will start working again correctly without having to configure it further. (See point 4).

8. REPLACING THE BATTERIES ON THE LEM RF ROOM PROBE

NOTES

Tecnosystemi S.p.A.

Via dell’Industria, 2/4 - Z.I. San Giacomo di Veglia

31029 Vittorio Veneto (Treviso) - Italy

Tel +39 0438.500044 - Fax +39 0438.501516

email: [email protected]

Tax Code - VAT no. - R.I.TV IT02535780247 Share Capital € 5,000,000.00 fully paid

www.tecnosystemi.com

800 904474

ONLY FOR ITALY

5. ZONE CHECK

6. LEM RF ROOM PROBE STATUS

7. RESETTING THE LEM RF ROOM PROBE

Press the button on the back once. The LED will flash for the same number of times as the 

zone assigned at one-second intervals: the LEM is thus forced to communicate with the 

Polaris 3X control panel as well.

The LED flashes every 60 seconds to indicate that is working properly.

Press  the  button  for  10  seconds  until  the  blue  LED  starts  flashing  rapidly. The  probe  is 

waiting to receive the control panel ID signal (see point 4).

10. WARRANTY

11. DISPOSAL

The warranty lasts 2 years from the date of delivery.

The supplier company guarantees the quality of the materials used and the correct construction of 

the components. The warranty covers defects in materials and manufacturing defects and refers 

to the supply of spare parts of any components featuring defects, without any compensation, 

interest or claim for damages.

The warranty does not cover the replacement of components damaged due to:

•  incorrect transportation;

•  installation not compliant with that specified in this installation, use and maintenance manual;

•  non-observance of product technical specifications;

•  Anything else that is not linked to original faults of the material or production provided that the 

customer complaint is covered by the guarantee and a claim is made within the time limit and 

in the way requested by the supplier, the same supplier will commit, at their own discretion,  

to replace or repair any product or part of product showing signs of faults or defects.

At the end of its useful life, the product must not be disposed of with household 

waste. It can be deposited at a dedicated recycling centre run by local councils, or 

at retailers who provide such a service. To highlight the requirement to dispose of 

household electrical items separately, there is a crossed-out waste paper basket 

symbol on the product.

Отзывы: