Tecnosystemi 11132650 Скачать руководство пользователя страница 7

USER MANUAL

“TSAT1” DIGITAL THERMO-ANEMOMETER

COD. 11132650

Tecnosystemi S.p.A.

via dell’Industria, 2/4 - Z.I. San Giacomo di Veglia 

31029 Vittorio Veneto (Treviso) - Italy

Phone +39 0438.500044 - Fax +39 0438.501516

Numero Verde 800 904474 (only for Italy)

email: [email protected]

C.F. - P. IVA - R.I.TV IT02535780247 Cap. Soc. € 5.000.000,00 i.v.

www.tecnosystemi.com

Accessories for

                       Air Conditioning

     Ventilation

                        Solutions 

    

Air Curtains and

                       Accessories

 

 Accessories

                     For Heating

Instruments &

                         Tools

Multi - Zone

Air Control System

Содержание 11132650

Страница 1: ...A via dell Industria 2 4 Z I San Giacomo di Veglia 31029 Vittorio Veneto Treviso Italia Tel 39 0438 500044 Fax 39 0438 501516 Numero Verde 800 904474 only for Italy email info tecnosystemi com C F P...

Страница 2: ...devono essere tenute lontane dal sensore DURANTE L USO CARATTERISTICHE 1 Display la riga superiore del display mostra sempre la velocit o il volume la riga inferiore del display mostra sempre la temp...

Страница 3: ...n modalit di attesa dei dati 2 Indica il valore visualizzato come valore massimo MAX 3 Indica il valore visualizzato come valore minimo MIN 4 Valori misurazione 5 Unit Temperatura 6 Unit Velocit 7 Ind...

Страница 4: ...re il tasto ancora una volta per spegnere l alimentazione 2 Tasto FUNC Funzione di commutazione della modalit di misurazione Premere il tasto per cambiare la velocit del vento il volume dell aria o la...

Страница 5: ...Lo strumento si spegner automaticamente dopo 20 minuti se non si esegue alcuna operazione con i tasti Funzione di spegnimento automatico annullata Premere e tenere premuto il tasto ON OFF fino a quan...

Страница 6: ...NOTE 6...

Страница 7: ...1029 Vittorio Veneto Treviso Italy Phone 39 0438 500044 Fax 39 0438 501516 Numero Verde 800 904474 only for Italy email info tecnosystemi com C F P IVA R I TV IT02535780247 Cap Soc 5 000 000 00 i v ww...

Страница 8: ...asurement readings all the interference sources which may affect the measurement result about temperature and humidity such as the hand must be away from the sensor DURING USE FEATURES 1 Display the t...

Страница 9: ...of the symbols represented by the following table N OF ORDER SYMBOL FUNCTIONS 1 Indicating it is now in the data holding mode 2 Indicating the display value being the maximum value MAX 3 Indicating t...

Страница 10: ...n stable read the value TYPE A TEMPERATURE VANE ANEMOMETER 1 ON OFF key Power ON OFF function Press the key to turn the power ON and press the key once more to turn the power OFF 2 FUNC KEY Measuremen...

Страница 11: ...to select AP ON or AP OFF then press the Mode key to confirm the setting AP ON Auto power off availability AP OFF Auto power off unavailability UNIT The meter may be wiped down with a wet sponge or cl...

Страница 12: ...warranty does not cover the replacement of components damaged due to incorrect transportation installation not compliant with that specified in this installation use and maintenance manual non observ...

Отзывы: