IU_BasicLine_01_eng
5
Delete the user
!
Press and hold
key “3” until double signal;
the light remains switched on during the
following actions.
!
Enter the main code.
!
The user is now deleted.
Membrane check-up
!
Press and hold
key “5” until double signal.
!
Enter the following sequence of numbers:
1-2-3-4-5-6-7-8-9-0.
o
Double signal = key correctly working.
o
Long signal = key not working.
Set time delay
!
Press and hold
key “9” until double signal;
the light remains switched on during the
following actions.
!
Enter the main code.
!
Enter time delay value (2 digits, from 00 to 99 minutes) and open window value (2
digits, from 01 to 19 minutes) (double signal).
o
For instance if you want to program 26 minutes delay and 12 minutes open
window, enter: “2612”.
!
Confirm time delay value and open window value (double signal).
Note: Time delay value can be increased in every moment; to decrease it, lock must be in
open window.
Battery change
A series of signals during opening indicates that the battery is weak and must be replaced.
Only use fresh 9V-ALKALINE batteries from brand name manifacturers like DURACELL
TM
.
Содержание T6530/DL
Страница 1: ...U S E R I N S T R U C T I O N S ...