![Tecnosicurezza MiniTech T52 Series Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/tecnosicurezza/minitech-t52-series/minitech-t52-series_installation-instructions-manual_1072075010.webp)
10 of 20
II_ MiniTech_05_eng
Installation instructions
MiniTech
SwingBolt lock installation instructions
The SwingBolt lock is a swinging bolt lock whose block is carried out by a motor; it can be
installed in all 4 directions, even upside down.
By entering a valid code, the lock electronic removes the blocking for 3 seconds and the
boltwork can be moved into open position by pushing the bolt inside the lock case.
The bolt automatically secures when the safe handle, or the safe door mechanism, is brought
to the locked position.
If the SwingBolt is used in conjunction with other locks, the safe door mechanism must ensure
the closure of the SwingBolt before the other locks.
The lock can be mounted in all four mounting directions (RH, LH, VU, VD).
Furthermore, by flipping over the lock, both locking directions can be realized.
In the locked position the distance between the lock’s bolt and the lock part
that moves the lock bolt should be approximately 1 mm.
The bolt must be able to move freely without force being applied to it.
The maximum load applicable to the bolt must not exceed 1 KN. Contact Tecnosicurezza in
case of heavier loads.
Connect the keypad cable to the lock connector "1/ENT", making sure it is fully inserted and
locked.
Any alarm interface or battery holder needs to be connected to the lock connector “2/BAT”.
To remove the cable, bring the connector upwards and carefully pull it out.
It’s possible to connect a relocker to the lock cover through the appropriate holes.
Fix the relocker plate with M4 self tapping flat head screws.
Length must be 6mm + plate thickness.