![Tecnoplastic SPIDER Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/tecnoplastic/spider/spider_instructions-manual_1072019003.webp)
ENGLISH
NOTES: DO NOT TAMPER WITH THE FLOAT SWITCH. THE NON RESPECT OF THE FOLLOWING POINTS
WILL AUTOMATICALY CAUSE THE CANCELLATION OF THE WARANTY OF THE PRODUCT
Ÿ
Before any opera on on the float remember to disconnect the power supply from the main power.
Ÿ
Check that the maximum motor power does not exceed the float's electrical values.
Ÿ
In case of cable damage by the final user or installer, the float must be replaced.
Ÿ
Do not make any joint on the cable of the float switch, as immersion of such joints could cause short circuits or
electrical shocks.
USE:
The electronic controller is designed to work in clear and rain water. The batons, a ached to the body, allow the level
regulator to work in narrow spaces and in difficult environments with turbulent water.
The electronic regulator has two delay mes: start and stop (shutdown) which can be adjusted by the final customer
according to his needs of use. And thanks to the Schuko Piggy Back Plug (accessory sold separately) it can be
connected directly to a pump without the need of a tradi onal electronic panel.
TECHNICAL FEATURES:
- Opera ng temperature: max.+40°C (+104°F)
- Max depth:
10m (32,8 )
- Protec on Grade: IP 68
Features of automa c ac on: 1B (micro-disconnec ons in opera on)
- Pollu on Degree: 2
SET DELAY TIMES:
The first me you connect the plug to the electrical system, the electronic controller will perform a 5 seconds
startup test to check the func oning.
Factory default delay me:
Ÿ
Star ng Delay Time: 0 seconds.
The pump turns on 0 seconds a er the water has raised touching the two sensors
placed at the bo om of the electronic regulator.
Ÿ
Shutdown Delay Time: 0 seconds.
The pump turns off 0 seconds a er the water has flowed down releasing the
sensors.
Change the
1
. Disconnect the plug from the electrical system
2.
Put the magne c key
Star ng/Delay Time (Fig.1)
close to the arrow stamped on the side of the electronic controller.
3.
Connect the plug to turn on the pump.
4.
Hold
the magne c key in posi on for how many seconds you wish to delay the star ng me
(maximum 120 seconds)
.
5.
Once you got the desired delay me, remove the magne c key.
Change the
1.
Connect the plug to the electrical system.
2.
Wait for the pump
Shutdown Delay Time (Fig.2)
shutdown.
3.
Put the magne c key close to the
arrow
shown on the side of the electronic regulator and the pump
starts.
4.
Hold the magne c key in posi on for the seconds necessary to delay the shutdown
(maximum 120
seconds)
.
5.
Once reached the desired me, remove the magne c key.
HOW TO CUT THE BATONS:
In case of necessity it is possible to cut the batons to adapt the Spider to your own applica on:
Don't cut the batons directly connected to the float.
1. Unscrew the 3 batons. 2. Saw them and remove the metal flash - 3. Cut away about 2/3mm of rubber at the end - 4.
Remove the cap of the rubber from the cut piece and insert it into the new baton - 5. Screw again the batons to the
pins. Remember to keep the same connec on type as illustrated in the front cover of these instruc ons:
COM and
MIN must keep the same length but longer than MAX
Connec on without plug
M
Grey
Yellow
/
Green
Black
Brown
N
L
Connec on with Schuko Piggyback plug
Brown
Grey
Black
Yellow
/
Green
L
N