background image

    

TT 73

MICROPROCESSOR-BASED

DIGITAL ELECTRONIC TIMER

OPERATING INSTRUCTIONS

Vr. 01 (ENG) - cod.: ISTR 06083

TECNOLOGIC S.p.A.

VIA INDIPENDENZA 56

27029 VIGEVANO (PV) ITALY

TEL.:  +39 0381 69871

FAX: +39 0381 698730

internet : http:\\www.tecnologic.it

e-mail: [email protected]

PREVIOUS STATEMENT

:

In this manual are contained all the necessary information for a
correct installation and the instructions for the use and the
maintenance of the product; we recommend, therefore, to read
carefully the following instructions. 
The maximum care has been used in the realisation of this
document, anyway TECNOLOGIC S.p.A. does not assume any
responsibility deriving from the use of itself. 
The same consideration has to be done for each person or
Company involved in the creation of this manual. 
The herewith issue is an exclusive property of  TECNOLOGIC
S.p.A. which forbids any reproduction and divulgation, although
partial, if not expressly authorised. 
TECNOLOGIC S.p.A. reserves the right to execute aesthetically and
functional modifications, at any moment and without  any notice.

INDEX

INSTRUMENT CODE

7.5

FUNCTIONAL DATA

7.4

MECHANICAL DIMENSIONS, PANEL CUT OUT AND
FIXING DEVICE

7.3

MECHANICAL DATA

7.2

ELECTRICAL DATA

7.1

TECHNICAL DATA

7

WARRANTY AND REPAIRS

6.2

CLEANING

6.1

TROUBLES, MAINTENANCE, WARRANTY

6

PARAMETERS DESCRIPTION 

5.2

PARAMETERS TABLE

5.1

PROGRAMMABLE PARAMETERS

5

CNT EN INPUT OPERATING MODE

4.5

OUT 2 OPERATING MODE

4.4

OUT 1 OPERATING MODE

4.3

DISPLAY  OPERATING MODE

4.2

COMMANDS OPERATING MODE

4.1

OPERATING MODE

4

ELECTRICAL CONNECTION DRAWING

3.4

ELECTRICAL  CONNECTIONS

3.3

MECHANICAL MOUNTING

3.2

USE ALLOWED

3.1

INSTALLATION AND USE ADVICES

3

PARAMETERS LOCK

2.3

PARAMETERS PROGRAMMING

2.2

SET POINT PROGRAMMING 

2.1

PROGRAMMING

2

FRONT PANEL DESCRIPTION

1.2

GENERAL DESCRIPTION

1.1

INSTRUMENT DESCRIPTION

1

1 - INSTRUMENT DESCRIPTION

1.1 – GENERAL DESCRIPTION

TT 73 is a programmable microprocessor based timer with 1or 2
outputs.
The instrument offers the possibility to program: up to 3 set points
time, 5 operating modes for the output OUT1, 4 operating modes for
the output OUT2, 4 time scales (from 9999 hrs. maximum to 0.1
sec. minimum), 4 functioning modes of counting enable and 2
counting modes (UP or DOWN). 
The instrument can have an inside back up battery (optional) which
permits the counting also without power supply. 
The counting state is visualised on 4 digits display  while the outputs
state is signalised  by a led. 
The instrument can have 2 outputs (relay or to drive solid state
relays) and 2 digital inputs for count enable (CNT EN) and reset
(RES) which can be for free voltage contacts or voltage signals (the
same voltage supply value).
The programming of the instrument is possible by means of the 3
keys placed on the front while  the counting is possible using the
frontal key START/STOP or using the back inputs CNT EN and
RES.

1.2 - FRONT PANEL DESCRIPTION

1 - Key P

 : Used for the set point setting and to program the

functioning parameters

TECNOLOGIC spa - TT 73

 

- OPERATING INSTRUCTIONS - Vr. 01 - ISTR 06083 - PAG. 1

Содержание TT 73

Страница 1: ...G MODE 4 4 OUT 1 OPERATING MODE 4 3 DISPLAY OPERATING MODE 4 2 COMMANDS OPERATING MODE 4 1 OPERATING MODE 4 ELECTRICAL CONNECTION DRAWING 3 4 ELECTRICAL CONNECTIONS 3 3 MECHANICAL MOUNTING 3 2 USE ALLOWED 3 1 INSTALLATION AND USE ADVICES 3 PARAMETERS LOCK 2 3 PARAMETERS PROGRAMMING 2 2 SET POINT PROGRAMMING 2 1 PROGRAMMING 2 FRONT PANEL DESCRIPTION 1 2 GENERAL DESCRIPTION 1 1 INSTRUMENT DESCRIPTIO...

Страница 2: ...dify the Set Point To have again access at the parameters repeat the same procedure pushing key P and selecting uL finally go out from the parameters lock modality 3 INSTALLATION AND USE ADVICES 3 1 USE ALLOWED The instrument has been projected as measure and control device built according to EN61010 1 for the altitudes operation until 2000 ms The use of the instrument for applications not express...

Страница 3: ...rior brightness with the purpose to limit as much as possible the absorption from the battery 4 3 OUT1 OPERATING MODE The instrument can be programmed by the parameter F1 to operate in any of the following 5 modes F1 1 DELAYED On receiving the START signal the instrument starts counting time When the set time value t1 has been reached the instrument enables the output OUT1 The output is disabled b...

Страница 4: ...ction of delay with the time t3 while if F1 2 or 3 the output OUT 2 operate with the feedthrough function always with the time t3 In the programming mode of the time t3 the display shows t3 i to indicate that the time t3 is independent F2 4 Same function of OUT1 time t1 with time t3 relative to t1 in advance The choice of this mode of operation enable the set t3 that it has the same range time S1 ...

Страница 5: ...ing of the CNT EN input the counting is stopped This operating mode is recommended when the user wants to control the timer using voltage signals In fact with an appropriate interface eg an external relay the timer is reset and starts counting when voltage is supplied and stops when voltage is cut off just like a conventional timer In this functioning mode the T frontal key works only as reset 5 P...

Страница 6: ...under warranty against construction vices or defected material noticed within 12 months from delivery date The warranty is limited to the repairs or to the substitution of the instrument The eventual opening of the housing the violation of the instrument or the wrong use and installation of the product means the automatic decay of the warranty In case of defected instrument noticed in warranty per...

Страница 7: ...uracy 0 1 fs Counting autonomy in case of power failure 10 hrs approx with full charge battery Inputs delay 15 m sec Max Display 4 Digit Red h 14 mm Compliance ECC directive EMC 89 336 EN 61326 ECC directive LV 73 23 and 93 68 EN 61010 1 7 5 INSTRUMENT CODE TT 73 a b c d e ff a POWER SUPPLY F 12 VAC VDC Y 24 VDC A 24 VAC C 110 VAC D 230 VAC b INPUTS C Free voltage contacts V Voltage signals the sa...