3 - Key UP

 : This is used to increase the values to be set and to

select the parameters. If the key is held down, the user returns to
the previous programming level until he exits the programming

mode. Outside the programming mode it permits visualisation of
the maximum peak measure.

4 - Key U

 : This is a key with a function programmable by par.

“USrb” (see par. 4.4). It permits to modify the visibility of the
parameters in “ConF” menu (see par. 2.3).

5 - Led OUT1 

: indicates the state of output OUT1 

6 - Led OUT2 

: indicates the state of output OUT2

7 - Led SET 

:It indicates access to the programming mode and

parameter programming level.

2 -  PROGRAMMING

2.1 - PARAMETERS PROGRAMMING

By pushing key "P" and holding it down for approx. 2 sec. it is
possible to enter into the main selection menu.

Using the "UP" or DOWN” keys, it is then possible to roll over the
selections:

to exit from the selection and come back to normal
functioning 

"rEt"

 to enter into the configuration parameters menu

"ConF"

 to enter into the operating parameters menu

"OPEr"

Once the desired item has been selected, push key “P” to confirm.
Selecting "OPEr" and "ConF" gives the possibility of accessing

other menus containing additional parameters and more precisely :

"OPEr" –

 Operating parameters Menu: it’s accessible without

password, and can contain all the desired parameters (see par.

2.2).

"ConF" –

 Configuration parameters Menu: this contains all the

operating parameters and the functioning configuration parameters.

2   s e c .

H o ld  fo r

To enter the menu 

"ConF"

, select the option “ConF” and press the

key “P”, the display will now show “0”.
At this request, enter, using keys “UP” and “DOWN”, the number

reported on the last page of this manual and push key “P”.
If an incorrect password is entered, the instrument returns to the

previous state.
If the password is correct, the display will visualise the code
identifying the first group of parameters (“

]

InP

“) and with keys “UP”

and “DOWN” it will be possible to select the desired group of
parameters (see parameters table).

Once the desired group of parameters has been selected, the code
identifying the first parameter of the selected group will be

visualised by pushing the “P” key.
Again using the “UP” and “DOWN” keys, it is possible to select the

desired parameter and, if the key “P” is pressed, the display will
alternatively show the parameter’s code and its programming value,

which can be modified by using the “UP” or “DOWN” keys.
Once the desired value has been programmed, push key “P” once

more: the new value will be memorised and the display will show
only the code of the selected parameter.

By using the “UP” or “DOWN” keys, it is then possible to select a
new parameter (if present) and modify it as described above.

To select another group of parameters, keep the “UP” or “DOWN”
key pressed for approx. 2 sec., afterwards the display will return to

visualise the code of the group of parameters.

Release the key and by using the “UP” and “DOWN” keys, it will be
possible to select a new group.

To exit the programming mode, no key should be pressed for
approx. 20 seconds, or keep the “UP” or “DOWN” pressed until exit

from the programming mode is obtained.

Longer

Hold

2 sec.

Hold for

2 sec.

Hold for

ATTENTION:

 The instrument is programmed in factory with all the

parameters, to exception of the Alarm thresholds AL1, AL2 (if
available) programmable in the menù "ConF" to the purpose to
prevent wrong accidental programming from non experienced
consumers.

2.2 - PARAMETERS PROGRAMMING LEVELS

The menu 

“ConF”

 (protected by password) contains all the

parameters, however it is possible to program all desired
parameters in the menu 

“OPEr”

 (without protection by password)

by following this procedure:
Enter the menu “ConF” and select the parameter to be made

programmable or not programmable in the menu “OPEr”.
Once the parameter has been selected, if the LED SET is switched

off, this means that the parameter is programmable only in the
menu “ConF”, if instead the LED SET is on, this means that the

parameter is also programmable in the menu “OPEr”.
To modify the visibility of the parameter, push key “U” : the LED

SET will change its state indicating the parameter accessibility level
(on = menu ”OPEr” and “ConF”; off = menu “ConF” only).
To enter the menu 

“OPEr”

, select the option “OPEr” and press the

key “P”.
The display will now show the code identifying the first group of

parameters present and by pressing the “UP” and “DOWN” keys it
will be possible to select the group of parameters to be modified.

The programming and exit modes for the “OPEr” menu are the
same as those described for menu “ConF”.

2.3 - FAST PROGRAMMING OF THE ALARM THRESHOLDS

If the alarm outputs are used this procedure permits rapid

programming of the the alarm thresholds.
This procedure is possible only if the relative parameters of alarm

threshold are present in "OPEr" menu.
The possible modification of these value, with the procedure

described, is instead subordinate to what is programmed in par.

“Edit”

 (contained in the group “ 

]

PAn 

“).

This parameter can be programmed as :

= AE : The alarm thresholds can be modified
= AnE : The alarm thresholds can be visualized on the dispay but

cannot be modified
Once you have configure the alarm thresholds as “OPEr”

parameters to visualize or visualize and program the value  push
key “P” then release it during the normal state of the instrument.
The display will visualise 

“AL 1”

 alternatively to the programmed

value.
To modify the value, press “UP” key to increase it or the “DOWN”

key to decrease it (this is possible only if   “Edit”=AE).
These keys change the value one digit at a time but if they are

pressed for more than one second, the value increases or
decreases rapidly and, after two seconds in the same condition, the

changing speed increases in order to allow the desired value to be
reached rapidly.

Once the desired value has been reached, by pushing key P it is
possible to exit by the fast programming mode or it is possible to

visualise the other alarm thresholds.
To exit the fast alarm thresholds programming it is necessary to

push key P, after the visualisation of the last threshold, or

TECNOLOGIC spa - TLV 38

 

- OPERATING INSTRUCTIONS - Vr. 01 - ISTR 06612 - PAG. 2

Содержание TLV 38

Страница 1: ...DIAGRAM 3 4 ELECTRICAL CONNECTIONS 3 3 MECHANICAL MOUNTING 3 2 PERMITTED USE 3 1 INFORMATION ON INSTALLATION AND USE 3 FAST PROGRAMMING OF ALARM THRESHOLDS 2 3 PARAMETER PROGRAMMING LEVELS 2 2 PARAMETER PROGRAMMING 2 1 PROGRAMMING 2 FRONT PANEL DESCRIPTION 1 2 GENERAL DESCRIPTION 1 1 INSTRUMENT DESCRIPTION 1 1 INSTRUMENT DESCRIPTION 1 1 GENERAL DESCRIPTION TLV 38 is a digital microprocessor based ...

Страница 2: ...oup To exit the programming mode no key should be pressed for approx 20 seconds or keep the UP or DOWN pressed until exit from the programming mode is obtained Longer Hold 2 sec Hold for 2 sec Hold for ATTENTION The instrument is programmed in factory with all the parameters to exception of the Alarm thresholds AL1 AL2 if available programmable in the menù ConF to the purpose to prevent wrong acci...

Страница 3: ...n external transformer TCTR or with equivalent features and to use only one transformer for each instrument because there is no insulation between supply and input We recommend that a check should be made that the parameters are those desired and that the application functions correctly before connecting the outputs to the actuators so as to avoid malfunctioning that may cause irregularities in th...

Страница 4: ... see par U key with function USrb Hold When the HOLD function is actived the instrument works on the alarms in operation depending on the memorized measurement 4 3 ALARMS OUTPUTS FUNCTIONS AL1 AL2 The alarms AL1 AL2 are depending on the process value and before to set his functioning it s necessary to establish to which output the alarm has to correspond to First of all it s necessary to configure...

Страница 5: ...ction Pressing the key for at least 1 sec the display will show the writing 0 Pot for approx 1 sec and then 0 assuming the value measured in that instant as 0 r Pic Pressing the key the highest and lowest peak values are re set r P0P For the instruments with normalized signals input it is possible to set the zero value and contemporarily re set the highest and lowest peak values with this function...

Страница 6: ...scription Par 1 000 0 000 2 000 Rotation of the measuring straight line rot 9 0 1999 9999 Measuring Offset OFSt 8 1 0 0FF 20 0 sec Input digital filter FiL 7 C C F Temperature unit of measurement Unit 6 0 Pt1 Ptc ntc 0 1 norm sig 0 3 Number of decimal figures dP 5 Group Out parameters relative to the outputs ALno ALno ALnc ALni OFF Functioning of output 2 see O1F O2F 11 ALno ALno ALnc ALni OFF Fun...

Страница 7: ...urther to its expiry please contact our sales department to obtain authorisation for sending the instrument to our company The faulty product must be shipped to TECNOLOGIC with a detailed description of the faults found without any fees or charge for Tecnologic except in the event of alternative agreements 7 TECHNICAL DATA 7 1 ELECTRICAL DATA Power supply 12 VAC VDC 24 VAC VDC 100 240 VAC 10 Frequ...

Страница 8: ... 0 20 mA SEnS 0 20 50 0 110 0 C 58 0 230 0 F 50 110 C 58 230 F NTC 103 AT2 SEnS ntc 55 0 150 0 C 67 0 302 0 F 55 150 C 67 302 F PTC KTY81 121 SEnS Ptc 199 9 850 0 C 199 9 999 9 F 200 850 C 328 1562 F Pt100 IEC SEnS Pt1 0 1760 C 32 3200 F tc S SEnS S 0 1370 C 32 2498 F tc K SEnS CrAl 0 1000 C 32 1832 F tc J SEnS J dP 1 2 3 dP 0 INPUT 7 6 INSTRUMENT ORDERING CODE TLV38 a b c d ee f a POWER SUPPLY F ...

Отзывы: