Standalone mode
Standalone mode
allows the device to command ANY DEVICE through the NO/NC contacts and to use auxiliary
command and/or alarm functions directly from the
TASFD6T
device.
Connec on diagram
Cable color
Nome conta o
Funzione
Basic Standalone wiring
Red
12/28 V +
12/28 Vac/dc – Power input
Black
12/28 V –
12/28 Vac/dc – Power input
Blue
NO
Normally open relay output
(Install diode provided)
Purple
COM
Common connec on for relay output
Orange
NC
Normally closed relay output
(Install diode provided)
Advanced Input and Output features
Pink
GND
Ground – Nega ve pole
Yellow
Input_1
Device for opening the lock input (ex: internal exit bu on)
Grey
Output_Alarm
Nega ve contact for Alarm (Voltage 12 -28 Vac/dc – 2 A)
Brown
Sensor
Opening sensor input (Normally closed)
WARNING:
In
Standalone
mode if the power supply of our product is the same that feeds the accessory on the exchange
auxiliary contacts, you must put the diode marked in blue supplied.
In
Standalone
mode it isn’t mandatory to connect all the cables of the
TASFD6T
, for example in the absence of an
exit bu on it is possible to leave the yellow cable disconnected but it must not make contact with the others to
avoid malfunc ons.
tecnoautomation
T.A. Tecno Automazione s.r.l.
- Via Vicinale snc - 03018 - Paliano - (FR) - Italy - Tel +39 0775 533677 - Fax +39 0775 533299 - info@tecnoautomazione.com -
www.tecnoautomation.com
-