TECNO AIR SYSTEM
Essege Group
pag. 25 di 40
• Keep informed about current disposal options from your dealer or from your Local Council.
• Before scrapping the appliance, cut the power cord and make it useless.
4. INSTALLATION
UNPACKING
• Open the carton being careful do not damage the appliance with sharp tools,
•gently pull up the stove out from the packing, beware the glass,
•remove all protections and packing materials before using the stove and make sure that you have removed
all the accessories inside: pump, lighter WP18, essence holder, feet, booklet instructions, elettrical tools, all of
the stickers and the internal packagings parts of the stove.
INSTALLATION
After unpacking the appliance, place it in a secure and stable place that has been awarded, making sure that
there is enough space for the preliminaries.
Make sure to place the stove in a right position to avoid possible impacts.
Be shore to leave the fan air intake grid always free.
The stove do not requires chimney, anyway the room must be ventilated for a few minutes each hour of use.
The stove must be installed in compliance with the following safety conditions:
-Keep a minimum distance on the sides, in front of an above of 50 cm and 10 cm on the back by an average
of flammable materials;
3. TECHNICAL SPECIFICATIONS
COMPACT
WIDTH
mm
486
DEPTH
mm
350
HEIGHT
mm
820
BIOETHANOL TANK CAPACITY
litri
5
NET WEIGHT
kg
36
GROSS WEIGHT
kg
40
FUEL
BIOETHANOL ECOFIRE
NOMINAL OUTPUT
Kw
3,8
AUTONOMY RANGE
ore
25
MAXIMUM CONSUPTION
LT/h
0,5
MINIMUM CONSUMPTION
LT/h
0,2
ADJUSTABLE FEET
kg
SI
RATED POWER
W
60
SUPPLY VOLTAGE
V~
220
NOMINAL FREQUENCY
Hz
50
ELECTRIC INSULATION CLASS
1
INTERNATIONAL PROTECTION
IP 20
WARRANTY
2 years