TECNARE V 10 Скачать руководство пользователя страница 25

V series User’s Manual 

25/28 

5.3  RIGGING 

5.3.1  Safety 

Flown Systems 

 

Installation and set up must be carried out by qualified personal. 

 

Inspect  the  all  the  rigging  components  for  damage  before  assembly.  Do  not  use 

damaged parts. Contact your supplier for replacements. 

 

Ensure that motor hoists, hoist control systems and ancillary rigging components are 

currently certified as safe and that they pass a visual inspection prior to use. 

 

Ensure the work area is isolated from public access. 

 

Do not leave the system unattended during the installation process. 

 

Do not leave any  object on top of the  system. It may fall when the system is flown 

and is likely to cause injury. 

 

Secondary  safety  steels  must  be  installed  once  the  system  has  been  flown  to  the 

operating height. 

 

Ensure  that  the  system  is  secure  and  prevented  from  pivoting  around  the  motor 

hoist. 

 

NEVER use other item than Tecnare accessories. 

 

When  flying  outdoor  systems  ensure  that  the  system  is  not  exposed  to  excessive 

wind or snow loads and is protected from rainfall. 

 

When  deploying  Tecnare  Systems  always  wear  protective  headwear,  footwear  and 

eye protection 

 

Ensure  that  all  local  and  National  regulations  regarding  the  safety  and  operation  of 

flying equipment are understood and adhered to. 

Ground Stacking 

 

Always  employ  safe  lifting  procedures  and  never  attempt  to  build  stacks  without 

sufficient personnel and equipment. 

 

Never allow anyone to climb onto a ground stacked PA system.  

 

If  the  stage  surface  slopes,  ensure  that  the  system  is  prevented  from  sliding 

forwards due to vibration. 

 

For  outdoor  systems  ensure  that  the  system  is  protected  from  wind  forces  which 

might cause the ground stack or become unestable. 

 

Apply the same attention to all safety matters when de-stacking systems. 

 

 

 

 

Содержание V 10

Страница 1: ...V SERIES USER S MANUAL ...

Страница 2: ...ection Diagram 17 5 2 4 Pcc Advaced Software User s Manual 17 5 2 4 1 INSTALLATION 17 5 2 4 2 USING THE PCC CONTROLLER ADVANCED SERIES 17 5 3 RIGGING 25 5 3 1 Safety 25 5 3 2 Single V10 V12 V15 26 5 3 2 1 Flown Vertically 26 5 3 2 2 Mounted On a wall 26 5 3 2 3 On wind stand or on SW118 27 6 Contact 28 1 INTRODUCTION Thanks for purchasing TECNARE This product comprises the best quality designed to...

Страница 3: ...chnology versions Self powered systems of high efficiency and low weight Systems individually DSP controlled by software in real time Graphical Equalizer of 30 bands by acoustic box Parametric Equalizer of 10 bands by acoustic box Individual control of gain solo and mute Individual Crossover of four bands Linkwitz Riley of 24dB octave Individual Compressor Limiter by band Variable delay on each ba...

Страница 4: ...rsonnel 1 READ THESE INSTRUCTIONS All the safety and operating instructions should be read before the product is operated 2 KEEP THESE INSTRUCTIONS The safety and operating instructions should be retained for future reference 3 HEED ALL WARNINGS All warnings on the product and in the operating instructions should be adhered to 4 FOLLOW ALL INSTRUCTIONS All operating and use of instructions should ...

Страница 5: ...T IS USED USE CAUTION WHEN MOVING THE CART APPARATUS TO AVOID INJURY FROM TIP OVER Do not place this unit on an unstable cart stand tripod bracket or table The unit may fall causing serious injury to someone and serious damage to the appliance A unit and cart combination should be moved with care 13 UNPLUG THIS APPARATUS DURING LIGHTNING STORMS OR WHEN UNUSED FOR LONG PERIODS OF TIME For added pro...

Страница 6: ... these PCC speakers are linked by a network through a USB interface to the laptop Once connected we can control in real time the parameters of each speaker such as volume graphic equalisation parametic equalisation crossover internal delays compressor limiters check test save and recall of presets mute transfer spectrum analysis r t a spectrum control phase check and more Consisting of seven model...

Страница 7: ...s Power Handling 520W nominal 1040W continuous Dimensions HxWxD 645x390x392mm Net weight 29 kg selfpowered Pcc version Components 1x12 LF driver 1x1 5 HF driver on a rotatable exponential horn V 15 Frequency Response 42Hz 17kHz 4dB Nominal Dispersion 80ºH x 60ºV 6Db Rotatable horn allows swap of horizontal and vertical pattern Impedance 8 Ohm Sensitivity 101dB 1w 1m Calculated max SPL 130dB Contin...

Страница 8: ...The absolute latest in available technology is utilized with 64 bit floating point processors and high performance 24 bit Analogue Converters The high bit DSP prevents noise and distortion induced by truncation errors of the commonly used 24 bit fixed point devices A complete set of parameters include I O levels delay polarity 8 bands of parametric EQ per channel multiple crossover selections comp...

Страница 9: ... 5 Rotary thumb wheel CH A Allows you to switch between presets To select the desire preset press the wheel 6 On SIGNAL CLIP led CH A When On indicates the unit is On Signal at the input and the input level is above the device s maximum headroom respectively 7 8 Ethernet connector Standard RJ 45 female socket 9 Power switch Controls power On Off 5 1 3 3 REAR PANEL FUNCTIONS 1 Main Power Connects v...

Страница 10: ...V series User s Manual 10 28 5 1 4 V Series Recommended configurations ...

Страница 11: ...V series User s Manual 11 28 ...

Страница 12: ...V series User s Manual 12 28 ...

Страница 13: ... recall of presets mute transfer spectrum analysis real time analyzer spectrum control phase check 5 2 1 Main Features Ethernet control 10 built in presets without the use of the software Unlimited presets storage in the PC Input graphic eq Parametric eq on each band 4 x 8 bands General Delay 4 band crossover Gain control Mute control Check test Buit in Analyzer Real time control Presets storage i...

Страница 14: ...V series User s Manual 14 28 5 2 2 Back Panel Original Series ...

Страница 15: ...V series User s Manual 15 28 Advanced Series ...

Страница 16: ...V series User s Manual 16 28 Cobranet Series ...

Страница 17: ...2 USING THE PCC CONTROLLER ADVANCED SERIES The Tecnare PCC Controller advanced series software application provides real time control and configuration editing for the DPA 28X using a laptop or other PC compatible computer In addition the application provides control over each individual input channel Gain Graphic EQ Compressor main delay and over each individual output channel Crossover 8 bands p...

Страница 18: ... Load an existing preset from your computer Save Preset Save the current preset to a file Load Set Click this option to Load a Set of 10 preset from your computer Save Set Save the current set of 10 presets to a file Exit Exit the application CONNECT On line Connects the computer to the unit DELAY UNITS ms meter feet NETWORK WINDOW When the PC is connected to the unit the following information is ...

Страница 19: ...he one on Red Double click to activate the unit By clicking on the group ID box the user will be able to assign each unit to a group SIGNAL GENERATOR By selecting active in the dropdown list a pink noise signal is generated by the 8 output channels The output level is controlled by the fader control INPUT LEVEL Main delay in ms meters or feet can be adjusted in this section The input level is adju...

Страница 20: ...nal It is calibrated in decibels with a range from 40 0 dBu to 17 dBu Attack This determines how fast the compressor reacts once the threshold has been exceeded It is calibrated in milliseconds with a range from 1 ms to90 ms Release This determines how fast the compressor turns off once the signal falls below the threshold It is calibrated in milliseconds with a range from 10 ms to 2500 ms 2 5 sec...

Страница 21: ...ifferent modes o Spectrum Analyzer o Transfer Function o Phase Response o Impulse Response Average Eight different time average can be selected 1 5 10 20 30 50 80 and 120 Window Signal Windowing by None Hamming Triangular Hanning and Blackman Smooth Is the frequency average None 1 3 1 6 1 12 1 24 Octave Input and Output Allows the user to choose the PC input and output device Pink noise Enable the...

Страница 22: ...ible to visualize both signal simultaneously TRANSFER FUNCTION It shows the systems transfer function meaning the difference between the signal from the output of the DPA 28X to the microphone input signal PHASE RESPONSE It allows the user to analyze the phase response of an installation IMPULSE RESPONSE This tool provide the spectrum impulse response of a certain room NETWORK This button toggles ...

Страница 23: ...te CROSSOVER This section contains two crossover filters per output Three different kinds of filters can be selected Bessel Butterworth L R The order of the filter can be selecting by pulling down the Bypass dropdown list Second Order filter 12dB Octave and Fourth Order filter 24dB Octave are available Filter cut off Frequency ranges from 20 to 20 000Hz in 1Hz steps PARAMETRIC EQ Eight bands param...

Страница 24: ...o orange To copy the desire equalization to other output just click on Copy button go to the desire output parametric EQ and click on the paste button LIMITER Threshold The THRESHOLD controls are continuously adjustable from 40dBu maximum limiting to 17dBu Bypass Turn the module in bypass mode Attack Ranges from 0 1 to 90ms Release Ranges from 2x to 32x LEVEL DELAY Level The output level can be ad...

Страница 25: ...at the system is secure and prevented from pivoting around the motor hoist NEVER use other item than Tecnare accessories When flying outdoor systems ensure that the system is not exposed to excessive wind or snow loads and is protected from rainfall When deploying Tecnare Systems always wear protective headwear footwear and eye protection Ensure that all local and National regulations regarding th...

Страница 26: ...lace the Double stud ring into the cargo restraint track 5 3 2 2 Mounted On a wall Items required LP_V10 LP_V12 LP_V15 L_V10 L_V12 L_V15 Procedure Remove the two up side screws from the box Place the LP_V accessory and secure it with 2 screws Hold the L_V10 L_V12 L_V15 to the wall Place the unit into the L_V accessory and secure it with two screws ...

Страница 27: ...V series User s Manual 27 28 5 3 2 3 On wind stand or on SW118 Items required 1x Wind stand ...

Страница 28: ...V series User s Manual 28 28 6 Contact Exel Acoustics S A Poligono Industrial Monte Boyal C Encinar 282 45950 Casarrubios del Monte Toledo Spain sales tecnare com Phone 34 918 170 110 Fax 34 918 183 053 ...