FILTER CLEANING 

 

Wash the filter every two weeks during use. If the filter is too impregnated with 
dust, the efficiency of the air conditioning will be reduced. 
 
To do this : Remove the air inlet grille and remove the strainer on both sides as 
shown in the following figures. 
Remove the filter and place it in warm water (approx. 40 ° C) with neutral 
detergent, rinse with clean water and dry in the shade after cleaning. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

STORAGE 

 
-Ensure the unit is completely cool and dry. 
-Do not wrap the cord around the appliance, as this will cause damage. 
-Keep the appliance in a cool, dry place. 

 

SEASONAL CLEANING (wintering) 

 

If the air conditioner is not used for a long time, 

Open the water tank (see DRAINAGE OF CONDENSATION WATER) 

Run the air conditioner in fan mode for 2 hours to dry the interior and that it will be 
completely dry. 
Turn off the air conditioner and unplug it. 
Clean the filter and the strainer (see filter cleaning) and reassemble them. 
Disassemble the exhaust pipe, tighten it and store it correctly. 

Содержание TCL-12003

Страница 1: ...use in order to avoid damage due to incorrect use and to better understand the functions of this product Please pay particular attention to the safety guide If you pass the device on to a third party...

Страница 2: ...shower wash hand basins or other containers with water Never use this apparatus near water projections Never use this apparatus with the wet hands If unfortunately the apparatus is wet immediately wit...

Страница 3: ...ages Never use the appliance if cord or appliance shows any signs of damage Never immerse the appliance in water or any other liquid for any reason whatsoever Never place it into the dishwasher Never...

Страница 4: ...do not come in contact with water Before cleaning always unplug the appliance from the power supply and let it cool down This appliance is not intended to be operated by means of an external timer or...

Страница 5: ...ut this type of repair GENERAL INFORMATION The symbol OPEN BOOK means a recommendation to read important things contained in the record The symbol BIN crossed out abbreviation WEEE Waste of Electrical...

Страница 6: ...ignite easily in contact with a flame or spark or under the influence of heat and take all precautions accordingly The symbol TRIMAN indicates that the consumer is invited to dispose the product as p...

Страница 7: ...e case of flammable refrigerants shall not be installed in an unventilated space if that space is smaller than 11 8m2 Compliance with national gas regulations shall be observed Mechanical connections...

Страница 8: ...industry recognised assessment specification Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of other skilled personnel s...

Страница 9: ...a shall be instructed on the nature of work being carried out Work in confined spaces shall be avoided The area around the workspace shall be sectioned off Ensure that the conditions within the area h...

Страница 10: ...eyed to make sure that there are no flammable hazards or ignition risks No Smoking signs shall be displayed Ventilated area Ensure that the area is in the open or that it is adequately ventilated befo...

Страница 11: ...ently resistant to being corroded or are suitably protected against being so corroded Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks a...

Страница 12: ...e to cables excessive number of connections terminals not made to original specification damage to seals incorrect fitting of glands etc Ensure that the apparatus is mounted securely Ensure that seals...

Страница 13: ...nder no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks A halide torch or any other detector using a naked flame shall not be used Leak...

Страница 14: ...system both before and during the brazing process Removal and evacuation When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used Howe...

Страница 15: ...s available Charging procedures In addition to conventional charging procedures the following requirements shall be followed Ensure that contamination of different refrigerants does not occur when usi...

Страница 16: ...ndling refrigerant cylinders all personal protective equipment is available and being used correctly the recovery process is supervised at all times by a competent person recovery equipment and cylind...

Страница 17: ...linders ensure that only appropriate refrigerant recovery cylinders are employed Ensure that the correct number of cylinders for holding the total system charge are available All cylinders to be used...

Страница 18: ...correct recovery cylinder and the relevant waste transfer note arranged Do not mix refrigerants in recovery units and especially not in cylinders If compressors or compressor oils are to be removed en...

Страница 19: ...ventilation grille 4 Casters 5 Air inlet 7 Air inlet 8 Air outlet 9 Drainage nozle 10 Air inlet grid 11 Remote control 12 Vent pipe for hot air 13 Adjustable sealing plate the window Connectable to th...

Страница 20: ...the timer Press both up and down keys simultaneously to change temperature in Fahrenheit degrees or Centigrade Celsius degrees 5 Mode key Press the key to select Cool Vent Dry 6 Timer button A Press t...

Страница 21: ...sealing plate is adjustable Notes It is important to keep the air duct the most linear possible Avoid being bent Incorrect installation will affect the work of the air conditioner Ensure that air can...

Страница 22: ...the speed Sweet or Strong Fan mode By pressing the Mode key 2 it is possible to select the Ventilation mode Press either the remote control or the control panel the ventilation indicator lights up Pr...

Страница 23: ...by mode press the Timer key to set the activation time Press the Up and Down keys to set the activation time 1 24H The timer indicator lights up In on mode press the Timer key to set the stop time Pre...

Страница 24: ...de after cleaning STORAGE Ensure the unit is completely cool and dry Do not wrap the cord around the appliance as this will cause damage Keep the appliance in a cool dry place SEASONAL CLEANING winter...

Страница 25: ...ts of the apparatus or the accessories rising from a defect of materials or manufacture by repair or replacement The services within the framework of the guarantee do not involve any extension of the...

Страница 26: ...cian for repairs This apparatus satisfied EC directives it was controlled according to all the European current directives like electromagnetic compatibility EMC and low tension LVD This apparatus was...

Страница 27: ...0 245g Global Warming Potential 3 kgCO 2 eq Refrigerant leakage contributes to climate change Refrigerant with lower global warming potential GWP would contribute less to global warming than a refrige...

Страница 28: ...28 more information Fontenay sous Bois France...

Отзывы: