background image

 

 

RELEASE TIME

: Alarming release time, 2-60s selectable, the default is OFF. 

 

4.3.9 Advanced   

 

 

 

 

 

 

 

 

PWR ON ACTION

: Power on action can be set as Memory, A-B scan, Pan scan, Park 

action, Guard tour 01, Guard tour 02, Guard tour 03 and No action. 

RATIO SPEED

: Ratio speed can be set as ON or OFF status. 

AUTO FLIP

: Auto flip can be set as ON or OFF status.   

WIPER MODE

: Wiper mode can be set as ON or OFF status. 

WIPER SPEED

: Wiper speed 1-5 level adjustable. 

WIPER TIMES

: Wiper times 1-5 times adjustable. 

<OTHERS>

: Set other options. 

4.4 Camera 

 

 

 

 

 

 

 

CAM

: Display the information of module supported by this dome. 

ZOOM SPEED

: Zoom speed is quick and slow selectable. 

DIGITAL ZOOM

: Digital zoom is on/off selectable. 

FOCUS

: Focus is auto and manual selectable 

IRIS

: Iris is auto and manual selectable 

BLC

: BLC is ON and OFF selectable   

<ADVANCED> 

PWR ON ACTION      MEMORY 
RATIO SPEED       

 

ON 

AUTO FLIP                            ON 
WIPER MODE                      OFF 
WIPER SPEED                        5 
            WIPER TIMES            2 
<OTHERS> 
EXIT 

<CAMERA>

 

CAM                                          AUTO 
ZOOM SPEED                        QUICK 
DIGITAL ZOOM                          OFF 
FOCUS                                      AUTO 
IRIS                                            AUTO 
BLC                                              OFF 
FREEZE                                      OFF 
EXIT 

Содержание Z-HA2PS6SW18

Страница 1: ...2MP Mini 18X PTZ Z HA2PS6SW18...

Страница 2: ...flash with arrowhead symbol within an equilateral triangle is intended to alert the user the presence of non insulated dangerous voltage within the product s enclosure that maybe of sufficient magnit...

Страница 3: ...e or disassemble any internal parts of the video camera to avoid normal operation and possibly void the warranty There are no serviceable parts inside the camera All electrical connections to the dome...

Страница 4: ...maged in any way when liquid traces are present or the presence of loose objects is evident or if the device does not function properly or has received sever impact or has been dropped accidentally 11...

Страница 5: ...2 4 Ceiling Mounted 11 2 3 Installation of Brackets 12 2 3 1 Wall Mounted 12 2 3 2 Corner Mounted 13 2 3 3 Pole Mounted 14 2 3 4 Ceiling Mounted 15 2 4 Connection 16 3 Function Instruction 17 3 1 Powe...

Страница 6: ...Clean Transparent Cover 28 Appendix Common Knowledge on RS 485 Bus 28 1 Basic Feature of RS 485bus 28 2 Mode of Connection and Terminal Resistance 28 Appendix Exception Handling 29 Copyright Statement...

Страница 7: ...1 Product Introduction 1 1 Package Contents IR Speed dome 1pc Wall mount bracket 1pc Power supply 1pc Screws kits 1pc User manual 1pc...

Страница 8: ...ard Tours 3 groups Guard Points Max 16 points dwell time user selectable Home Pos Time 1 60mins available PWR on Action Restore as power up Pan scan A B scan Park action Guard tour group 1 3 No action...

Страница 9: ...neon lamp etc 4 Targets are behind the glass covered with water droplets or dust 5 Targets are moving quickly 6 Monotonous large area targets such as wall 7 Targets are too dark or faint BLC If a brig...

Страница 10: ...en preset is called Guard Tours Dome patrol scans according to certain edited preset order Power Off Memory This feature allows the dome to resume its previous preset or status after power is restored...

Страница 11: ...In order to avoid losses of cable causing low voltage and keep the dome work properly when processing wiring please refer to the requirement below Cable diameter 0 5mm 20 1 0mm 18 1 5mm 16 2 5mm 14 D...

Страница 12: ...2 2 2 Corner Mounted Bracket 2 2 3 Pole Mounted Bracket 2 2 4 Ceiling Mounted...

Страница 13: ...expansion bolt in indoor and outdoor environment The wall can bear at least 4 times the weight of the dome Install wall hanging bracket a As shown in fig 2 with the installation holes in the undersid...

Страница 14: ...the dome Install corner mounted attachment and wall hanging bracket a As shown in fig 12 with the installation holes in the corner mounted attachment as pattern draw punched locations on the wall with...

Страница 15: ...and outdoor environment whose diameter should match the installation size of stainless hose clamps Factory default is 6 inches stainless hose clamps fit 130 152mm pillar The pole structure can bear a...

Страница 16: ...can be used in the hard ceiling structure whose thickness should be enough to install expansion bolt in indoor and outdoor environment The ceiling can bear at least 4 times the weight of the dome Ins...

Страница 17: ...aying surface of the base of hang ceiling and the ceiling board and around the out holes to be sure water proof c As shown in the fig 21 tighten the boom with electrical wire and cable through it on t...

Страница 18: ...utton to make the lens closer and magnify the scene Focus Press FOCUS button close shot will become clearer while long shot will become fuzzy Press FOCUS button long shot will become clearer while clo...

Страница 19: ...low table for details Remark Please do not change the parameter of the Sub OSD menu randomly to avoid any unexpected happen Please reboot the PTZ after switch the video signal output 3 3 Shortcut comm...

Страница 20: ...nt Right Enter the option select the item or confirm Left Return to main menu or cancel Angle Display XXX XX pan XXX XX tilt IR Display Display on the lower right corner of the screen Remark 1 Items w...

Страница 21: ...4 OSD Menu 4 1 Menu Index...

Страница 22: ...the product upgrading TEMPERATURE Display the temperature of the camera it changes along with the temperature of the camera the data is unchangeable by manual Remark Protocol ID and COMM all can be s...

Страница 23: ...unication setting is enable 4 3 2 IR Display WORKING MODE IR Working mode has auto black white color selectable Default is auto TESTING TIME On IR auto working mode and the programmed time the IR will...

Страница 24: ...The number of the preset is from 0 64 but 0 is not valid Dwell time is 1 to 60s selectable Speed is 1 to 64 grade selectable INIT After initial preset point dwell time and speed will resume to defaul...

Страница 25: ...guard tour 02 guard tour 03 and Preserve action When park mode is OFF status the dome doesn t run park mode When park mode is PRESERVE ACTION status it records previous action order A B scan Pan scan...

Страница 26: ...to stop it set mask to OFF status If the module doesn t support privacy mask the screen will display the interface as Fig 4 3 7 3 4 3 8 Alarm Optional ALARM Alarm has OFF and ON selectable PATROL TIME...

Страница 27: ...iper speed 1 5 level adjustable WIPER TIMES Wiper times 1 5 times adjustable OTHERS Set other options 4 4 Camera CAM Display the information of module supported by this dome ZOOM SPEED Zoom speed is q...

Страница 28: ...nt action such as A B scan Call preset Save preset Call park action Pan scan etc User can enable or disable it IR IR is ON and OFF selectable DOME ID At the top left corner of screen it displays the d...

Страница 29: ...s used in the area which opened and steel pipe units grounded in one point Overhead wiring is absolutely prohibited In the strong thunderstorms area or areas with high induced voltage such as high vol...

Страница 30: ...rt is serious user can use a mild detergent Any senior furniture cleaning products can be used to clean the under cover Appendix Common Knowledge on RS 485 Bus 1 Basic Feature of RS 485bus According t...

Страница 31: ...Set the correct protocol baud rate and address of dome device Improper connection of control cable polarity Verify the polarity of the RS485 connection as per the instruction manual Noise after self t...

Страница 32: ...Therefore the company reserves the right to modify or improve the products described in this manual without notice The content of manual is offered according to the current state Unless applicable law...