Technoware ECO 0.50 Скачать руководство пользователя страница 10

 

User’s manual 

8

 

UPS ECO  0.50 – 0.70 – 0.90 – 1.1 – 1.3 

 

6.2

 

Battery Mode 

The UPS automatically runs in 

Battery mode

 if the AC Input Line voltage amplitude gets out of security limits (in 

case of a black-out or over-voltage/low-voltage): in this case, the UPS supplies the required output power by its 
internal battery and by the Inverter block. 

The UPS automatically returns in Normal mode a few seconds after the AC Input Line is recovered. 

In Battery mode the UPS emits an acoustic alarm signal every 4 seconds and simultaneously the 

LINE/BATTERY

 led 

flashes.  

6.3

 

Low Battery and Automatic Restart 

In Battery mode, ECO indicates the 

Low Battery

 condition whenever the battery reaches a charge level allowing 

connected devices to operate for approximately one more minute.  

During  Low  Battery  condition  the  UPS  emits  an  acoustic  alarm  signal  every  second  and  simultaneously  the 

LINE/BATTERY

 led flashes. 

If  AC  Input  does  not  come  back  on  within  few  minutes,  the  UPS 

shuts-down  automatically

  thus  preventing  the 

batteries from discharging excessively; the UPS stops supplying Output power, deactivates control panel indication 
and goes to a waiting state. Once AC Input comes back on, the UPS

 restarts automatically 

and after some seconds 

it goes back to work in Normal mode. 

After  a  complete  discharge,  the  UPS  needs  4  hours  to  recharge  completely  the  batteries.  The  UPS  recharges 
batteries automatically if it works in Normal mode. 

6.4

 

Load Control 

During the functioning in Battery Mode, if the Output load is higher than nominal value (

Overload condition

), the 

UPS  may  automatically  switch  off,  protecting  itself  from  this  anomalous  situation.  In  this  case,  the  user  must 
reduce power within the specifications by disconnecting the devices that cause the 

Overload condition

 

 

Do not connect a load greater than rated value to the UPS (see POWER specifications in 
the chapter “Technical Characteristics”), as this may damage the unit. In this case the 
warranty is void. 

 

6.5

 

Fault Condition 

The UPS indicates the 

Fault condition

 by lighting of the 

Alarm 

led and by emitting a continuous acoustic alarm. 

During Fault condition, the UPS doesn’t supply Output power and so all the supplied devices are switched off. 

 

Содержание ECO 0.50

Страница 1: ...Uninterruptible Power Supply ECO 0 50 ECO 0 70 ECO 0 90 ECO 1 1 ECO 1 3 User s manual...

Страница 2: ......

Страница 3: ...8 Maintenance 10 8 1 UPS Cleaning 10 8 2 Battery 10 8 3 Battery Replacement 10 8 4 Operator Safety 11 9 Troubleshooting 12 Conformity to the European Directives 13 Product Disposal 13 Lead Batteries 1...

Страница 4: ...the batteries they will remain powered and therefore dangerous even after the UPS has been disconnected from AC power mains Before any repair or maintenance work disconnect the batteries by removing t...

Страница 5: ...ns for the operator for the UPS correct installation and gives useful advice on the product and battery maintenance For any type of problem please refer to this manual before calling the customer serv...

Страница 6: ...signed to operate in a protected environment e g offices We therefore recommend installing it in a place with very little or no humidity dust or smoke In all circumstances see the Technical Characteri...

Страница 7: ...there are see figure 1 1 The ON OFF button enables the user to turn ON OFF the UPS 2 The LINE BATTERY led this led blue color is always on during the functioning in Normal Mode it flashes one time eve...

Страница 8: ...the UPS 2 Connect the UPS Input socket to the AC line outlet through the Personal Computer supplying cable It is mandatory to ground the AC line outlet according to the Safety Standards Carefully che...

Страница 9: ...t point 3 The batteries reach the 90 of their capacity after about 4 hours of recharge It is compulsory to ground earth the UPS according to the Safety Standards Risk of electric shock at the Output l...

Страница 10: ...ing the batteries from discharging excessively the UPS stops supplying Output power deactivates control panel indication and goes to a waiting state Once AC Input comes back on the UPS restarts automa...

Страница 11: ...Single phase 230 Vac Output Voltage Regulation Normal mode As Input Output Voltage Regulation Battery mode 5 Output Inverter Waveform Modified Sinewave Accepted Overload 130 Certifications CE Standar...

Страница 12: ...onth Take in mind that batteries are recharged automatically if the UPS works in Normal mode or if the UPS is off and connected to the AC Input Line Battery life strongly depends on the ambient temper...

Страница 13: ...ay tools or metal parts on top of batteries e Disconnect the charging source prior to connecting or disconnecting battery terminals f Determine if battery is inadvertently grounded If inadvertently gr...

Страница 14: ...remain powered and therefore dangerous even after the UPS has been disconnected from AC power mains Before any repair or maintenance work disconnect the batteries by removing the positive cable red c...

Страница 15: ...urban waste but must be treated as a separate waste Any violation is indictable with financial sanctions as per in force regulations An incorrect waste disposal or an improper use of the same or of a...

Страница 16: ...TECNOWARE s r l www tecnoware com...

Отзывы: