Feel good through warmth from electricity - www.technotherm.de
Installation and Operating Instructions
VPS Design
Feel good through warmth from electricity - www.technotherm.de
GB
WARNING
Do not install this device in areas that present an explosion hazard like a garage. Remove all
protective coverage before turning on the device. When using the device for the first time you
might detect a strong odor. This is no reason for concern; it is caused by residues of production
and will disappear shortly.
The rising heat may cause stains on the ceiling, however this phenomena can be caused by any other
heating device as well. Only a qualified electrician may open or remove the device from the power
supply.
3. Maintenance
Before cleaning the device be sure to turn it off. To clean use a damp towel and a mild detergent.
3.1 Assembly instruction
This Manual is very important and has to be kept at a safe place at all times. Be sure to hand this ma
-
nual to any other succeeding owner of the device. The device comes with a power plug that has to be
plugged into an outlet.
The device is designed to be connected to 230V (nominal) alternating current (AC).
4.1 Wall Installation
When installing the device, the safety distance must be strictly adhered to, so that flammable materials
can not ignite. Install the device to a wall which is heat resistant up to 90 ° C.
• Due to possible fire hazard the safety distances are observed during assembly:
Side walls of the heater to any masonry:
5 cm
Side walls of the heater to combustible materials: 10 cm
Distance radiator to the floor:
25 cm
arranged spaced upper radiator limit to about components or covers (. Eg window):
flammable 15 cm
nonflammable 10 cm
To prevent inflammable materials from catching fire be sure to keep the prescribed safety distance
when installing the device. Mount the device to a wall that is fireproof up to 90 °C.
The safety distance to the floor should be 25 cm, and at least 10 cm to all other devices. Furthermore
there has to be safety distance of approximately 50 cm between the ventilation grille, windowsills, roof
slopes and ceilings.
If you want to install the device in your bathroom, be sure to keep it out of reach for people taking a
shower or a bath.
When mounting the device to the wall, be sure to keep to the dimensions as indicated in the illustration
on page 11. Drill two or three (if available) 7 mm holes and attach the corresponding plug. Then screw
the 4 x 25 mm screws into the holes, leaving a distance of 1-2mm between the head of the screw and
the wall.
Hang the device in the two or three fittings and tighten it down. See also the additional mounting infor
-
mation at the following pages!