17/04/2019
–
TPF-Eco version u111
•
Put your panel(s) into pairing mode by holding the button on the
receiver down for more than three seconds.
•
The thermostat will flash to show it is searching for receivers. It will
do this for about 10 seconds before it solidifies on the number of
panels it’s found, i.e. “P03” for three panels.
•
OPTIONAL
–
the last step is to set the wattage for each paired panel.
This allows the thermostat to measure the energy consumption of
your system. You can skip this step if you want.
o
SET WATTAGES
–
The thermostat will show you the code for each panel in turn, i.e.
“P01”, “P02”, etc. The receiver of the relevant panel will “tick” when its code shows,
so you know which wattage to enter. Use the +/- buttons to set the wattage and
press OK. Repeat until all panels are set.
▪
NOTE
–
Earlier versions of the receiver do not tick.
If your panels don’t tick,
you may find it easier to connect each panel separately.
o
SKIP
–
You can skip this step by repeatedly pressing OK, cycling through the panels.
You can set wattages later via CF18 in the
configuration menu
.
1B
–
Manual Mode
•
Make sure the thermostat is on. (Press
to toggle between shutdown and ON mode.)
•
Turn the dial to switch between the modes: auto (follows program), comfort, economy, anti-
frost and program (edit your program).
•
Comfort, economy and anti-frost are the three fixed heating modes. On these modes, the
TPF-Eco will tell the panels to switch on or off to maintain your set temperature for that
mode.
•
To adjust the set temperatures, turn the dial to your chosen mode, use the +/- buttons and
press OK. Temperature choices are restricted as follows:
o
Comfort
–
5-30 °C (or maximum comfort temperature).
▪
The mode for occupied places where
you want to be warm. E.g. living rooms,
dining rooms, evenings.
▪
Maximum comfort temperature can be
set via CF10 in the
config. menu
. Can be
set between 22
–
30 °C. Default is 28 °C.
o
Economy
–
5-19 °C
▪
This is the mode for when you
’re active
or absent from the room but
don’t
want the temperature to drop too low.
E.g. overnight, bathrooms, gyms.
o
Anti-Frost
–
5-10 °C