Installation and technical manual CHM heater

Feel good through warmth from electricity - www.technotherm.de

GB

|5

• 

Mode of operation: type 1.C (Micro-disconnection)

• 

Operating Temperature: -5°C to +50°C

• 

Storage Temperature: -10 °C +70°C

• 

Dimensions: 120 x 54 x 25 mm

• 

Degree of Protection : IP 44 - IK 04

• 

To be installed in average polluted Areas

WARNING

Do not install this device in areas that present an explosion hazard like a garage. Remove all protecti

-

ve coverage before turning on the device. When using the device for the first time you might detect 

a strong odor. This is no reason for concern; it is caused by residues of production and will disappear 

shortly.

The rising heat may cause stains on the ceiling, however this phenomena can be caused by any other 

heating device as well. Only a qualified electrician may open or remove the device from the power 

supply.

4. Maintenance

Before cleaning the device be sure to turn it off. To clean use a damp towel and a mild detergent.

5. Assembly instruction

This Manual is very important and has to be kept at a safe place at all times. Be sure to hand this manual 

to any other succeeding owner of the device.

The device is an electrical heater that was designed and intended to be mounted to walls. The device 

comes with a power plug that has to be plugged into an outlet.

The device is designed to be connected to 230V (nominal) alternating current (AC).

Содержание CHM 1000 DSM

Страница 1: ...00 DSM CHM 500 RF CHM 1000 RF CHM 1500 RF CHM 2000 RF Installation and technical manual CHM Heater castor feets THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE BE SURE TO OBSERVE ALL LABELS AND WARNINGS ON THE APPLIANCE Id Nr 911 360 511 Edition 01 18 This product is only suitable for well insulated rooms or for occasional use ...

Страница 2: ...undedsocketsonly Do not use the heater in any other way than described in the user ma nual Anyotherwayofusemayleadtofire electrocution andmaycause seriousharmtotheperson Donotusethisdevicenearbathtubs showersorswimmingpools Incasetheconnectioncableisdamagedithastobereplacedbythema nufacturerorsomeonecommissionedbythemanufacturer WARNING Donotuseaswitching orienteddevice likeatimekeeper when operat...

Страница 3: ...paint or any other flammable liquidsarestored Donotusethedeviceoutside Warning thisdevicehastobegrounded Thisdevicemayonlybeoperatedusingalternatingcurrentandtheoperating voltageindicatedonthepowerratingplate NominalVoltage 230VAC 50Hz ProtectionClass I DegreeofProtection IP20 RoomThermostat 7 Ctill30 C Thisdeviceisonlyformobileuselikewithcastorsorfeets ...

Страница 4: ...e the transmitter into the Configuration mode see user manual transmitter Check that the indicator light is no longer flashing Application Example The use of a room thermostat in combination with a opening detector is ideal because the opening de tector will detect if a window is open and will automatically switch to frost protection By pressing the receiver button for approximately 10 seconds you...

Страница 5: ... caused by residues of production and will disappear shortly The rising heat may cause stains on the ceiling however this phenomena can be caused by any other heating device as well Only a qualified electrician may open or remove the device from the power supply 4 Maintenance Before cleaning the device be sure to turn it off To clean use a damp towel and a mild detergent 5 Assembly instruction Thi...

Страница 6: ...tance when installing the device If you want to install the device in your bathroom be sure to keep it out of reach for people taking a shower or a bath 6 Installation of Electricity The device was developed for an electrical voltage of 230 V nominal and an alternating current of AC 50 Hz The electrical installation may only be performed according to the user manual and only by a qualified Electri...

Страница 7: ... Eco and the Eco interface Item Symbol Value Value Item Value Heat output Type of heat input for electric storage local space heaters only select one Nominal heat output Pnom 05 1 0 1 5 2 0 kW manual heat charge control with integrated thermostat NO Minimum heat output indicative Pmin 0 5 1 0 1 5 2 0 kW manual heat charge control with room and or outdoor temperature feedback NO Maximum continuo us...

Страница 8: ... output Pnom 05 1 0 1 5 2 0 kW manual heat charge control with integrated thermostat NO Minimum heat output indicative Pmin 0 5 1 0 1 5 2 0 kW manual heat charge control with room and or outdoor temperature feedback NO Maximum continuo us heat output Pmax c 0 5 1 0 1 5 12 0 kW electronic heat charge control with room and or outdoor temperature feedback NO Auxiliary electrici ty consumption fan ass...

Страница 9: ...g up the thermostats and interfaces please ask in our support see last page Model CHM DSM Operation only permitted in conjunction with the DSM interface Item Symbol Value Value Item Value Heat output Type of heat input for electric storage local space heaters only select one Nominal heat output Pnom 05 1 0 1 5 2 0 kW manual heat charge control with integrated thermostat NO Minimum heat output indi...

Отзывы: