3.4.13. Serial RS-232 connection
3.4.13.1 Serial RS-232 connection
Figure 3.21.
Serial RS-232 connection
3.4.13.2 Recommendation for wiring
a) If you build the serial cable, you can use a 3-wire shielded cable with shield connected to
BOTH ends. Do not use the shield as GND. The ground wire (pin 5 of J1) must be
included inside the shield, like the 232Rx and 232Tx signals
b) Always power-off all the iPOS4808 supplies before inserting/removing the RS-232 serial
connector
c) Do not rely on an earthed PC to provide the iPOS4808 GND connection! The drive must
be earthed through a separate circuit. Most communication problems are caused by the
lack of such connection