Technosoft 2014
51
iPOS4808 MX Technical Reference
3.4.7.
24V Digital I/O Connection
Figure 3.6.
24V Digital I/O connection
Remarks:
1. Connect the external load to the external V
LOG
for using the 24V outputs
2. The maximum sink current is 0.5A continuous, up to 1A pulsed for less than 5 seconds
3. The inputs are compatible with NPN type outputs (input must be pulled to GND to change
i
t’s default state)
4. The outputs are compatible with NPN type inputs (load is tied to V
LOG
, output
pulls to GND when active and is floating when inactive)