Technosoft 2021
35
iPOS360x HX-CAN Technical Reference
3.7 Electrical Specifications
All parameters measured under the following conditions (unless otherwise specified):
T
amb
= 0…40
°
C, V
LOG
= 24 V
DC
; V
MOT
= 24V
DC
; Supplies start-up / shutdown sequence: -
any-
Load current (sinusoidal amplitude / continuous BLDC,DC,stepper) = 4A iPOS3604/ 2A iPOS3602
3.7.1 Operating Conditions
Min.
Typ.
Max.
Units
Ambient temperature
iPOS360X HX-CAN
0
+40
ºC
Ambient humidity
Non-condensing
0
90
%Rh
Altitude / pressure
Altitude (referenced to sea level)
-0.1
0 ÷ 2.5
1
Km
Ambient Pressure
0
1
0.75 ÷ 1
10.0
atm
3.7.2 Storage Conditions
Min.
Typ.
Max.
Units
Ambient temperature
iPOS360X HX-CAN
-40
105
ºC
Ambient humidity
Non-condensing
0
100
%Rh
Ambient Pressure
0
10.0
atm
ESD capability (Human body model)
Not powered; applies to any accessible part
±
0.5
kV
Original packaging
±
15
kV
3.7.3 Mechanical Mounting
Min.
Typ.
Max.
Units
Airflow
natural convection, closed box
Spacing required for vertical mounting
Between adjacent drives
30
mm
Between drives and nearby walls
30
mm
Between drives and roof-top
20
mm
Spacing required for horizontal mounting
Between adjacent drives
4
mm
Between drives and nearby walls
5
mm
Space needed for drive removal
10
mm
Between drives and roof-top
15
mm
Insertion force
Using recommended mating connectors; without
retainer
20
36
N
Extraction force
5
10
N
3.7.4 Environmental Characteristics
Min.
Typ.
Max.
Units
iPOS360x HX-CAN
Size ( Length x Width x Height )
Without mating connectors
72.4 x 44.6 x 15.6
mm
~2.85 x 1.75 x 0.61
inch
Weight
70
g
Cleaning agents
Dry cleaning is recommended
Only Water- or Alcohol- based
Protection degree
According to IEC60529, UL508
IP00
-
3.7.5 Logic Supply Input (+V
LOG
)
Min.
Typ.
Max.
Units
Supply voltage
Nominal values
7
24
36
V
DC
Absolute maximum values, drive operating but outside
guaranteed parameters
4.9
42
V
DC
Absolute maximum values, surge
(duration
≤
10ms)
†
-1
+45
V
Minimum power supply voltage rising slew-rate
75
V/s
Supply current
+V
LOG
= 7V
125
300
mA
+V
LOG
= 12V
80
200
+V
LOG
= 24V
50
125
+V
LOG
= 40V
40
100
1
iPOS360x can be operated in vacuum (no altitude restriction), but at altitudes over 2,500m, current and power rating are reduced due
to thermal dissipation efficiency.