Change code 

(Safely store the new code and perform various opening / closing tests before closing the safe door)

 

 

 

To be performed with the door open! 

 

 

 

Press and hold 

 until the double beep. The LED remains on.

 

 

 

 

 

 

Enter the 

old code

.

 

 

 

 

 

 

Enter the 

new code

.

 

 

 

 

 

 

Confirm the 

new code

.

 

 

 

 

 

 

Perform various opening / closing tests before closing the safe door.

 

 

 

 

 

 

Activate a new user

 

 

 

 

 

 

Press and hold 

 until the double beep. The LED remains on.

 

 

 

 

 

 

Enter the Manager code.

 

 

 

 

 

 

Enter the number of the user to be installed (from 1 to 9).

 

 

 

 

 

 

If the user is available, the keypad beeps twice.

 

 

 

 

 

 

Enter the code to be associated with the user (and the Dallas key if necessary).

 

 

 

 

 

 

Enter again the code to confirm it (and the Dallas key if necessary). 

 

 

 

 

 

Disable/Enable users 

(Function not available if the dual code opening is activated)

 

 

 

 

 

 

Press and hold 

 until the double beep. The LED remains on.

 

 

 

 

 

 

Enter the Manager code. The keypad beeps twice.

 

 

 

 

 

 

All users are disabled/enabled.

 

 

 

 

 

 

Delete an user

 

 

 

 

 

 

Press and hold 

 until the double beep. The LED remains on.

 

 

 

 

 

 

Enter the Manager code.

 

 

 

 

 

 

Press the key corresponding to the user to be deleted (from 1 to 9).

 

 

 

 

 

 

The keypad beeps twice. The user is deleted.

 

 

 

 

 

 

Membrane test

 

 

 

 

 

 

Press and hold 

 until the double beep. The LED remains on. 

 

 

 

 

 

Enter the sequence of numbers from 1 to 0. A confirmation beep is given for each key. 

 

 

 

 

 

A damaged key is indicated with a long beep. 

 

 

 

 

 

Time delay 

(Time Delay programmable from 0 to 99 minutes; Open Window from 1 to 19 minutes)

 

 

Press and hold 

 until the double beep. The LED remains on.

 

 

 

 

 

 

Enter the Manager code. The keypad beeps twice. 

 

 

 

 

 

 

Enter the values for the time delay and the open window in two digits (e.g. 10 and 05).

 

 

 

 

 

 

Confirm the values for the time delay and the open window in two digits (e.g. 10 and 

05).

 

 

 

 

 

 

Attention, the time delay can only be lowered in the open window.

 

 

 

GLOBAL HEADQUARTERS 

USA HEADQUARTERS 

SPAIN HEADQUARTERS 

Tecnosicurezza SpA

 

Tecnosicurezza Inc.

 

Tecnosicurezza Sa

 

Via Cesare Battisti. 276

 

50, Thomas Lane

 

C/Menor, 4 - Nave 10

 

37057 San Giovanni Lupatoto 

Verona

 

Versailles, KY 40383

 

Pol. Ind La Mina 28770 

Colmenar Viejo

 

Tel.+39 045 826 64 70 

Tel.+1 859 490 89 30

 

Tel.+34 91 804 33 91

 

Fax. +39 045 826 64 69

 

 

Fax.+34 91 804 32 63

 

[email protected]

 

[email protected]

 

[email protected]

 

Отзывы: