background image

 

IU_Pulse10users_easy_02_eng

 

 

In the pre-setup mode, press 1 to open the lock and to activate the silent alarm. In pre-setup, programming can be 

performed through a Dallas key or by selecting one of the following 4 preloaded configurations (this last is not valid for 

EM6050):

 

 

 

No. configuration 

Maximum number of users 

Dual code 

 

 

No 

 

 

No 

 

 

Yes 

 

 

Yes 

 

 

Silent  alarm  option  can  be  activated  in  pre-setup  mode  thanks  to  a  setup  Dallas  key,  or  in  any  moment  by  simply 

connecting an alarm interface with the lock and entering an opening code. 

Select a keypad configuration (only in pre-setup status) 

 

Press the key 2 for few seconds, enter the code 555555 and select the desired configuration number.  

 

 

At the end of the configuration only the Manager is installed, with code 123456. 

 

 

If all users are blocked and only the Manager code is enabled, the time delay function is not available. 

 

Manager

 

  Optional Dallas key 

Open, program and change its own code 

Users 

xxxxxx  +  Optional Dallas key 

Open and change its own code 

 

 

Dallas key

 

In the event that the user is composed of "code + Dallas key", after entering the code, the Dallas key must be placed 

on the appropriate Dallas key reader. 

 

Override user 

The  override  user  9  opens  without  waiting  the  time  delay.  In  the  default  programming  they  are  set  in  dual  code 

opening but, upon request, the single opening mode can also be set. 

 

Silent alarm 

It is activated by increasing the last digit by one number when entering the opening code. 

 

Penalty

 

After four attempts to enter an incorrect code, the lock starts a 4-minute delay period. Each attempt to enter the code 

within the 4 minutes delay period restarts the count. 

 

Low battery warning 

A long beep during opening indicates a low battery level. 

Replace immediately the low battery with a new Alkaline battery. 

 

Sound signals

 

A double beep 

 normally indicates a correct

 

operation. A long beep 

 indicates an incorrect

 

operation and the 

end of the operation itself. 

 

Recommendations 

Do not use easily identifiable codes such as 123456, dates of birth or other personal information.

 

 

 

Pulse 10 users 

 

User instructions 

Opening 

(It is recommended to change the factory code before use and to safely store the new code) 

 

 

Enter the opening code (default Manager code 123456). 

 

 

 

If the code is correct, the keypad will beep twice.

 

 

 

 

If programmed, the time delay count starts. The LED flashes every 2 seconds.

 

 

 

 

A beep every 2 seconds indicates the end of the time delay count.

 

 

 

 

Enter the opening code. The keypad beeps twice.

 

 

 

 

Open the safe door within 4 seconds 

(with motorlock EM6050, 2 beeps and 2 LED flashes are produced when the lock re-closes).

 

 

 

 

Dual code opening 

(It is recommended to change the factory code before use and to safely store the new code)

 

 

 

 

Enter the first opening code. 

 

 

 

If programmed, the time delay count starts. The LED flashes every 2 seconds. 

 

 

 

A beep every 2 seconds indicates the end of the time delay count. 

 

 

 

Enter both opening codes. The keypad beeps twice. 

 

 

 

Open the safe door within 4 seconds. 

 

 

 