background image

Turning the device on

If the controller is in OFF mode and 60 seconds 

have passed since the last user interaction, the 
current time and temperature are shown on the 
display.

Fig 3

Controller turned off

Pressing any button shows the main screen 

(Fig 2).

Press and hold the power button 

 in order to 

turn on the controller. A menu showing the modes is 
displayed, the active is AUTO (Fig 4). Hold the 

 

button depressed for 3 sec in order to confirm the 
turning on of the device. If you want to switch to ON 
mode, use the navigation buttons to select it, then 
hold the 

 button.

To turn the device off follow the same procedure. 

When the mode is changed the beeper signals the 
new mode is accepted.

Fig 4

Turning ON

Temperature set point

If the current mode is ON, use the buttons 

 /

 to increase / decrease the temperature set point 

(the icon   indicates the temperature can be 
changed). In AUTO mode, the temperature is fixed by
the week timer 

 or the external thermostat.

Quick menu

Fig 5

Quick menu

To access the 

Quick menu

, press the button 

 

from the Main screen. For navigation use the buttons 

 / 

.

Maximum power

The controller modulates the current operating 

power so the temperature set point is reached. The 
maximum power can be limited (5 – maximum, 1 – 
minimum). Use the buttons 

 / 

 to decrease / 

increase the maximum power. Pressing the button

 sets the maximum value.

Bunker

The fuel level inside the bunker declines as the 

device is operating. In order to change the fuel level 
after loading it with pellets, use the buttons 

 / 

to increase / decrease the fuel level by 5%. Press the 
button 

 to increase the pellets level by 15 kg 

(1 bag).

Service

Indicates the remaining pellets quantity remaining

to the next servicing of the device, alongside with the
last date of servicing. Negative value means that the 
service period is overdue, indicated on the main 
screen by blinking icon 

.

When you have serviced the device, press 

 to 

reset the counter and the date.

4

Using the device

Содержание tPell

Страница 1: ...tPell Pellet Combustion Controller Version 24 06 20...

Страница 2: ...tings 5 Week Timer 6 Info 6 Outputs 6 Date Time 7 Errors Actions 7 Principle of operation 8 Work mode 8 ON AUTO 8 OFF 8 States 8 Clean 8 Ignition 8 Kindle 8 Burn 8 Purge 8 Shutdown 9 Wait 9 Service pa...

Страница 3: ...mostat on or off if used Current temperature the measured temperature of the heated object Power the current operating power when burning in kW or relative units Fumes fan revolutions of the fan in Fe...

Страница 4: ...In AUTO mode the temperature is fixed by the week timer or the external thermostat Quick menu Fig 5 Quick menu To access the Quick menu press the button from the Main screen For navigation use the but...

Страница 5: ...press to save the change or to cancel the modification and revert to the previous value Heating Fig 8 Heating Boiler Temp boiler temperature set point The power is modulated in order to achieve the te...

Страница 6: ...decrease increase the temperature by 0 5 C as with by 2 C Info Fig 11 Information On this screen usage information is displayed Pellet counter for the pellets burned from the last reset In order to re...

Страница 7: ...creen title in brackets Errors 6 the number of the registered errors is shown Press over selected element to get detailed information about it To switch between views use the buttons Errors The error...

Страница 8: ...by monitoring the temperature of flue gases or the flame intensity depending on configuration On successful ignition it passes to the next state If the ignition time runs out before ignition is detec...

Страница 9: ...e state However the device will automatically transition to ON mode when the system needs to generate heat The device is in standby awaiting for some of the heated objects to need heating When all the...

Страница 10: ...pause Feeder run All parameters listed below that set the feeder time have the meaning of Feeder Fan Max Maximum revolutions per minute of the fumes fan It is used to calculate the percents that set...

Страница 11: ...Turn on temperature Pump Min Temp Pump Hyst Turn off temperature Pump Min Temp Pump Hyst Wait DHW ON Temperature difference below the set temperature in order to exit from Wait state Wait DHW OFF Temp...

Страница 12: ...e specified the shutdown is started Wait Temp ON Difference between the current and set temperature under which the device immediately transitions from Wait to Burn state Wait Temp OFF Difference betw...

Страница 13: ...ignition Exceeding this temperature raise is considered for successful ignition Light Level Light sensor level exceeding it is considered for successful ignition Feeder2 Secondary feeder work time in...

Страница 14: ...alue of the parameter is OFF Purge Period Purge period When the device is in Burn state and the set time expires it transitions to Purge state Upon completion it returns back to Burn state The minimum...

Страница 15: ...ted and saved After changing the service password you will be asked again for it in order to access the service menu Stop Work Fig 18 Stop Work The device can be forced to stop ignoring the conditions...

Страница 16: ...g stopped In Burn state a loss of flame is detected according to the flue gases temperature or light intensity Power failure The power was cut for time exceeding the recovery time Feeder blocked The c...

Страница 17: ...ture sensor room temperature thermostat NTC 10K t4 Temperature sensor DHW Light sensitive i1 Light sensor flame intensity Active level GND i2 Hall sensor for fan revolutions counting i3 Capacitive ind...

Страница 18: ...Fig 20 Connection 18 Connection...

Страница 19: ...h square opening sized 128 x 57 mm To mount the controller first unscrew the mounting bracket then put the controller in the opening Fix it in place by putting the bracket on the back side and fasten...

Страница 20: ...term is 24 months from date of sale The guarantee is not valid in following cases Incorrect installation Attempts to make repairs and or modifications of equipment by the customer Visible damages of...

Отзывы: