EN4
601
– 1000 ppm eq
400
– 600 ppm eq
Your CO2 monitor measures and displays the CO2 in PPM with color
ventilation recommendations:
The
icons flash when the current CO2 exceeds 2000 ppm.
To set high alert and low alert of CO2 and humidity
1) Press and hold the
“
CO2/RH% / SET
” button (C4), the CO2 digits “
400
”
(default) flash and the
icon (A1) appears. Press the
“
+
“ or the “
-
“ button
to adjust the low alert level of CO2 in steps of +/- 10 PPM. Lowest alert level
is 400 PPM.
2) Press the
“
CO2/RH% / SET
” button (C4) again, the CO2 digits “
2000
”
(default) flash and the
icon (A2) appears. Press
the “
+
“ or the “
-
“ button
to adjust the high alert level of CO2 in steps of +/- 10 PPM. The highest
CO2 alert level is 5000 PPM.
3) Press the
“
CO2/RH% / SET
” button (C4) again, the humidity digits “
35
%”
(default) flash and the
icon (A1) appears. Press
the “
+
“ or the “
-
“ button
to adjust the low alert level of RH% in steps of +/-1%. Lowest alert level is
20%.
4) Press the
“
CO2/RH% / SET
” button (C4) again, the humidity digits “
70
%”
(default) flash and the
icon (A2) appears. Press
the “
+
“ or the “
-
“ button
to adjust the high alert level of RH% in steps of +/-1%. Highest alert level is
95%.
5) Press
“
CO2/RH% / SET
” button (C4) again to confirm and end setting.
The WL 1030 returns to normal display mode.
Содержание KA0601A-0501200EUS
Страница 1: ...DE1 WL 1030 Bedienungsanleitung Übersicht ...
Страница 12: ...EN1 WL 1030 Instruction manual Overview ...
Страница 22: ...FR1 WL 1030 Manuel d utilisation Vue d ensemble ...
Страница 33: ...ES1 WL 1030 Manual de instrucciones Vista general ...
Страница 44: ...NL1 WL 1030 Gebruiksaanwijzing Overzicht ...
Страница 54: ...IT1 WL 1030 Manuale di istruzioni Panoramica ...
Страница 65: ...CZ1 WL 1030 návod k obsluze Přehled ...
Страница 76: ...PL1 WL 1030 instrukcja obsługi Przegląd ...