Winsol
40
1
Read out logger data
Reading out of the logger data is started in the menu "
Logger \ Read out data
".
The data recorded and stored in the CMI are read out and saved as a log file in the
Winsol
file system on the PC. A log file is produced for each month in the corresponding sub-
directory ("...\log"). When data logging from two or more data records (devices)
Winsol
saves
its data in the sub-
directories "…\log1" and "…\log2" etc.. The file name of a log file contains
information about the year and month of the contained data. For example, the file
"
Y
2012
10
.log" contains the measuring data saved in
October
2012
.
Warning:
If the data of several systems are recorded, then before the data is read in, it must
be ensured that the correct "
Customer
" (see
Customer mode
) is selected!
Autostart
An automatic reading out of the data
when booting
the PC
can be implemented using the options in the menu "
Options \
Autostart
".
Selection of the customers that are automati-
cally read out when booting the PC.
The logger data store is then deleted if in the
customer setup, delete has been set to au-
tomatic or manual.
Autostart - Export to csv file
After reading out of the data, csv files are
automatically created in the selected format.
These files are saved in the folder <Data
path>\Infosol\Customer\csv. Existing files are overwrit-
ten.
Shut down computer
This option is also possible. Here, as the PC boots up, the data are automatically
read in (incl. possible csv conversion) and then the PC shutdown after the subse-
quent countdown.
1
2
2