background image

Product description

The 

TECHNITOP

 HAV 36 is a broadband amplifier for the frequency range 85-1006MHz with switchable 27/36 dB gain, 

separately adjustable level and slope correction and has a active return path range of 5-65 MHz.
The amplifier is approved exclusively for indoor installation.

Safety instructions

•  Installation of the amplifier must be done according IEC60728-11 and national safety standards.
•  The amplifier is powered from mains 230 V~. This voltage is dangerous to life.
•  Any repairs must be done by a qualified personnel.
•  The amplifier is double isolated from the mains 230 V~.
•  Do not remove the cover of the power supply section, without disconnecting the unit from the mains supply.
•  Do not plug the amplifier into the mains supply if the power cord or plug is damaged.
•  Do not plug the amplifier into the mains supply until all cables have been connected correctly.
•  To disconnect the amplifier completely from the mains, disconnect plug from the mains socket.
•  The mains socket must be easily accessible.
•  The amplifier shall not be exposed to dripping or splashing water and no objects filled with liquids, such as vases, shall 

be placed on it.

•  Avoid placing amplifier next to central heating components, near highly combustible materials and in areas of high 

humidity.

•  No naked flame sources, such as lighted candles, should be placed on amplifier.
•  If the amplifier has been kept in cold conditions for a long time, keep it in a warm room no less than 2 hours before 

plugging into the mains.

•  Do not insert any objects into ventilation openings.
•  The ventilation should not be impeded by covering the ventilation openings with items, such as newspapers, ta-

ble-cloths, curtains.

•  Mount the amplifier in vertical position with RF input connectors underneath.
•  From top, front and bottom of installed amplifier must be at least 10 cm free space.

External view and operating controls

Installation

The amplifier should be mounted on vertical surface with connectors underneath in order to ensure good ventilation 

conditions.
The amplifier must be fixed with 2 flat-head screws Ø 3.5-4 mm and appropriate wall-plugs if necessary. The screws are 

not included in a package.
Check that the supply voltage matches the particulars on the rating plate, then connect the amplifier to the power supply.

Technical data

Description

Unit

Value

Model

TECHNITOP

 HAV 36

item no.

0004/5608

EAN

4019588456082

Forward path

Frequency range

MHz

87 ... 1002

Gain

dB

27 / 36 (switchable)

Level attenuator

dB

15 (by 1 dB step)

Slope correction

dB

15 (by 1 dB step)

Return loss

dB

≥ 14  (@40 MHz; -1,5 dB/oct., min. 10 dB)

Output level

dBµV

109 (CTB, CSO, EN50083-3)

Noise figure

mA

≤ 6,5

Test output

dB

-20

Return path

Frequency range

MHz

5 ... 65

Gain

dB

27 / -3 (active / passive)

Level attenuator

dB

15 (by 1 dB step)

Slope correction

dB

-6 / -3 / 0

Output level

dB

115, activ (IMD3 = 60 dB (DIN45004B)

Return loss

dB

> 14

General

Supply voltage

230V ~ / 50 ... 60Hz

Power consumption

W

7

Nominal temperature range

°C

-20 ... 50

Dimensions (W x H x D)

mm

185 x 91 x 47

Disposal/Recycling instructions

Electronic equipment must not be disposed of in domestic waste. According to directive 2002/96/EC OF 

THE EUROPEAN PARLIAMENT AND COUNCIL of 27 January 2003 on waste electrical and electronic equip-

ment, it must be disposed of professionally. At the end of its service life, take this device for disposal at a 

designated public collection point.

Equipment is double insulated from the mains, with functional earthing.

Your device is CE approved and meets all necessary EU standards.
Subject to changes and printing errors.    Status 10/20
Reproduction and copies are only allowed with the consent of the publisher.
TechniSat is a registered trademark of

TechniSat Digital GmbH

 · TechniPark · Julius-Saxler-Str. 3 · D-54550 Daun

Input

Powering

indicator

Input attenuator 

return path

Gain switch 

forward path

Interstage equalizer 

forward path

Slope correction 

forward path

Attenuator 

forward path

Equalizer

return path

Mains

connection

Earthing clamp

Ingress filter 

return path

Activ/passive 

return path

Attenuator

return path

Output

Test

Input

Test

Output

Отзывы: