Note 2
: The
print documents
will be processed, then erased. Docu-
ments that do not conform to the method of analysis will be de-
stroyed automatically.
We therefore recommend specifying a directory that will be dedicated en-
tirely to the
ASCII
file sentinel for
CODESOFT
.
File Structure
ASCII files can consist either of direct and/or table assignments (see
Chapter 2
).
ASCII files require neither headers nor start and end-of-line delimiters.
However, it is essential to enter a hard return (CRLF characters) at the end
of each line in the file.
Note: some delimiters are configured by default
:
⇒
the assignment delimiter is defined by the ”=“ character;
⇒
the data separation delimiter is defined by the “,” character; and
⇒
the end-of-label delimiter is defined by the “END” character.
However, all of the above parameters can be redefined from the
Sentinel.ini file in the CODESOFT installation directory:
⇒
Affect ==,
⇒
SepData = ,
⇒
SepLabel = END.
Appendix 2 of Chapter
7
presents and discusses a sample print document
for a Print sentinel.
Содержание CODESOFT Sentinel Print Pack
Страница 4: ...Introduction Introduction 5 Definition of Concepts 5 How Sentinel Print Pack Works 6 ...
Страница 14: ...ASCII File Sentinel ASCII File Sentinel 15 File Structure 16 ...
Страница 17: ...Data Source Sentinel Data Source Sentinel 18 Structure of the Print Document 19 ...
Страница 21: ...Error Files Error Files 22 Structure of Error Files 22 Error Messages 24 ...