Page 80 • MNF18001EN / DOK-479-E ║ Issue/Rev. 1.4 (9/18)
MultiLevel Instruction Manual
MENU structure
*3114 – No. Wetleg interface
(wet-leg detector interface)
Setting showing how many wet-leg detector interfaces are installed. At present,
the software only supports one wet-leg detector interface.
*3115 – No. I/O interface
(wet-leg detector interface)
Setting to show how many I/O interfaces are installed. The I/O interface is used
to control the valves and is only in operation without NOMIX (in "Standalone"
mode). During operations with NOMIX, it takes charge of controlling the foot
valves and in-line valves.
9.7.1.2. Global CAN bus – 312
The parameters for the global CAN bus, also known as the external CAN bus, are set here.
MultiLevel uses the external CAN bus to communicate with other devices on the tanker
vehicle, e.g. NoMix 2000, EMIS (OBC), etc.
3121 – Global Node No.
The MultiLevel node number is set here;
the factory setting is no. "1". This node
number should not be altered under any
circumstances.
3122 – OBC Node
The EMIS node number is set here.
The factory setting is no. '0', since
communication with an on-board
computer (OBC) is not yet supported
by the EMIS interface. After completion
of the software, node number '21' will be
used in future. Please ensure that '21' is
also set as the dedicated EMIS node number.
3123 – NOMIX Node
The NoMix 2000 node number is set here. The factory setting is No. "11".
Please ensure that the dedicated node number '11' is also set for NoMix 2000.
During the calibration process, it is currently necessary to set node no. 10 for
both the NoMix and MultiLevel.
3124 – Print Manager
If several systems share a common printer, the node number of that print
manager needs to be set here. On the vehicle side, set No. "1". That means
that MultiLevel manages the printer. If for example NoMix 2000 starts a printout,
then that print order is sent to MultiLevel first. MultiLevel then sends the data to
the printer.
3125 – Time Target
Synchronization only occurs at the node set under parameter '3125'.
Parameter '3125' is not W&M protected
Factory setting: '21' (default EMIS)
Time synchronization can be deactivated with "3125" = 0.
No time synchronization takes place between 23:00:00 – 00:59:59.
Example:
• Pre-synchronization
- MultiLevel: 08.22.2011, 00:01:00
- EMIS: 08.21.2011, 23:59:00
• Post-synchronization:
- MultiLevel: 08.22.2011, 23:59:00
- EMIS: 08.21.2011, 23:59:00
Содержание Sening MultiLevel
Страница 6: ...Page 6 MNF18001EN DOK 479 E Issue Rev 1 4 9 18 Page intentionally left blank ...
Страница 22: ...Page 22 MNF18001EN DOK 479 E Issue Rev 1 4 9 18 Page intentionally left blank ...
Страница 36: ...Page 36 MNF18001EN DOK 479 E Issue Rev 1 4 9 18 Page intentionally left blank ...
Страница 52: ...Page 52 MNF18001EN DOK 479 E Issue Rev 1 4 9 18 Page intentionally left blank ...
Страница 131: ...Issue Rev 1 4 9 18 MNF18001EN DOK 479 E Page 131 MultiLevel Instruction Manual Form Layout ...
Страница 138: ...Page 138 MNF18001EN DOK 479 E Issue Rev 1 4 9 18 Page intentionally left blank ...
Страница 141: ...Issue Rev 1 4 9 18 MNF18001EN DOK 479 E Page 141 MultiLevel Instruction Manual Info and Errors Messages ...
Страница 143: ...Issue Rev 1 4 9 18 MNF18001EN DOK 479 E Page 143 MultiLevel Instruction Manual Info and Errors Messages ...
Страница 144: ...Page 144 MNF18001EN DOK 479 E Issue Rev 1 4 9 18 MultiLevel Instruction Manual Info and Errors Messages ...
Страница 145: ...Issue Rev 1 4 9 18 MNF18001EN DOK 479 E Page 145 MultiLevel Instruction Manual Info and Errors Messages ...
Страница 168: ...Page 168 MNF18001EN DOK 479 E Issue Rev 1 4 9 18 Page intentionally left blank ...
Страница 188: ...Page 188 MNF18001EN DOK 479 E Issue Rev 1 4 9 18 PRINT Menu MultiLevel Instruction Manual Short Overview of Menu System ...
Страница 227: ...Issue Rev 1 4 9 18 MNF18001EN DOK 479 E Page 227 MultiLevel Instruction Manual Drawings and Approvals 17 2 Approvals ...
Страница 228: ...Page 228 MNF18001EN DOK 479 E Issue Rev 1 4 9 18 MultiLevel Instruction Manual Drawings and Approvals ...