background image

www.technimount.com

BP71 UG 202108-01

13

Return to Table of Contents

WARNING/CAUTION/NOTE (CONTINUED)

CAUTION

 

9

Only certified technical personnel familiar with the bracket installation and use should manipulate it. Always refer 

to Technimount's user guides for all instructions for installing and using any Technimount Mounting System.

 

9

Inspect regularly all components on the equipment for any issue and loose screws, bolts and nuts.

 

9

Never install the mount into or on other similar mounting systems or brackets without written confirmation by 

Technimount System as these different systems may be from other brands or models and may not be compatible 

with Technimount Systems.

NOTE

 

9

Some cleaning products are corrosive in nature and may cause damage to the product if used improperly. If such 

products are used to clean Technimount equipment, the equipment must be rinsed with clean water and thoroughly 

dried following the cleaning. Failure to properly rinse and dry the Mounting Systems will leave a corrosive residue 

on the surface, possibly causing premature corrosion of critical components.

 

9

When ordering, it is important to identify on which mounting system you need to mount the bracket on as there 

are different systems for different applications (ground).  

 

9

A maintenance program should be established for all Technimount equipment. Preventive maintenance may need 

to be performed more frequently, based on the level of use of the product. Close attention should be given to 

safety features (i.e.: screws, quick release mechanisms, and attachment points).

 

9

Failure to use authorized parts, and lubricants, could cause damage to the equipment and will void the warranty 

of the product.

 

9

This user guide should be considered a permanent part of the bracket, and should remain with the product even if 

the equipment is subsequently sold.

 

9

Technimount  continually  seeks  advancements  in  product  design  and  quality.  Therefore,  while  this  user  guide 

contains the most current product information available at the time of printing, there may contain minor differences 

between your mounting system and this user guide. 

If you have any questions, or for more information, please contact Technimount Customer Service 

customerservice@

technimount.com

.

SUMMARY OF SAFETY PRECAUTIONS

Содержание PRO 71 Series

Страница 1: ...BRACKET PRO SERIE 71 USER GUIDE ...

Страница 2: ...nship with Philips Philips does not promote or sell Technimount products In order to ensure continuous improvements to our products and services we invite you to communicate your comments to our Customer Service Department at customerservice technimount com LEGAL NOTICE Technologies CGC Inc or Technimount E M S Holding Inc or its affiliates are not expressly associated with the marketing distribut...

Страница 3: ...our Technimount product its components or for any technical questions during the installation or maintenance processes please send an email to techsupport technimount com Please have the serial number of your Technimount product available as shown in the figure below when calling Technimount Technical Support Include the serial number in all written communications SERIAL NUMBER LOCATION CONTACT IN...

Страница 4: ...TION GUIDE 15 Removing the Packaging for Installation 15 Tools Required for Installation 15 Identification of Components 16 Top Locking Assembly 16 Front Support Plate 16 Hardware Kit 16 Installation of the IntelliVue X3 Monitor into the Bracket 17 OPERATION GUIDE 20 Removing the IntelliVue X3 Monitor from the Bracket 20 MAINTENANCE GUIDE 21 Cleaning 21 Cleaning Process 21 Removal of Iodine Compou...

Страница 5: ...E OF CONTENTS RETURN POLICY 28 Return Policy 28 Prior to 30 Days 28 Prior 45 Days 28 Prior 60 Days 28 Return Authorization 28 Damaged Merchandise 29 Claim Process 29 Required Information 29 Findings and Conclusion 29 Questions about our Policy 29 ...

Страница 6: ...s 6 BP71 UG 202108 01 www technimount com INTRODUCTION SYMBOLS AND DEFINITIONS SYMBOL DESCRIPTION Warning and Caution special attention is required Consult accompanying documents Safe working load symbol and Load balance symbol ...

Страница 7: ...serious injury It may also describe potential serious adverse reactions and safety hazards Caution Alerts the reader of a potentially hazardous situation which if not avoided may result in minor or moderate injury to the user or patient or damage to the equipment or other property This includes special care necessary for the safe and effective use of the device to avoid damage that may occur as a ...

Страница 8: ...PRO SERIE 71 Front View INTRODUCTION Rubber Cushions Inside the Bracket to Protect the Medical Device Locking Assembly Block with Black Anodized Finish 2 Side Support Blocks to Secure the Medical Device Technimount Molded Polyurethane Transport Handle Front Support Plate with Black Anodized Finish ...

Страница 9: ...RATION CONTINUED BRACKET PRO SERIE 71 Back View INTRODUCTION Rubber Pads Protecting the Bracket when Placed on a Surface Red Quick Release Mechanism for Easy Installation and Removal of the Medical Device Anti Rotation Micro Disc for Installation on Vertical and Wall Mounting Systems ...

Страница 10: ...nd install medical equipment owned by the customer on an incubator transport stretcher manufactured by Stryker and involving or not a Dräger or other incubator brand The purchase and use of products designed by Technimount are subject to this limitation of liability clause It is important to understand that as Technimount is not the manufacturer of the Stryker stretcher or other brand nor the manu...

Страница 11: ...icro Disc Transportation Compatibility System Compatible with Technimount s Safety MD Transporter vertical Vertical Mounting System Micro Base Features Access to all Medical Device Monitors Connectors and Accessories Rubber Pads Protecting the Bracket when Placed on a Surface Molded Polyurethane Transport Handle Rubber Cushions Inside the Bracket to Protect Medical Device Red Quick Release Mechani...

Страница 12: ... fall during transport and may cause injury to the patient or operator and or damage to the product 9 Do not allow untrained staff to assist in the operation of the mounting system Untrained technicians staff can cause injury to the patient or themselves 9 Do not place additional equipment or items onto the bracket or mounts other than approved Technimount or components as this could damage the pr...

Страница 13: ...ossibly causing premature corrosion of critical components 9 When ordering it is important to identify on which mounting system you need to mount the bracket on as there are different systems for different applications ground 9 A maintenance program should be established for all Technimount equipment Preventive maintenance may need to be performed more frequently based on the level of use of the p...

Страница 14: ...ount com WARNING The end user and administrator are responsible to validate regulations and standards for safety in their region in order to comply with applicable safety regulations Technimount is not responsible to inform the end user and or administrator of applicable legislation for safety in their area LEGAL NOTICE The purchase and use of products designed by Technimount are subject to this l...

Страница 15: ...d TOOLS REQUIRED FOR INSTALLATION Below are the basic tools required for installation Other tools may also be required If you have any questions regarding the installation or need assistance please contact our Technical Support team at techsupport technimount com 9 Phillips Screwdriver NOTE 9 Electrical tools are not recommended as there is a potential risk of damage to the threads 9 Technimount p...

Страница 16: ...e X3 Monitor inside the assembly FRONT SUPPORT PLATE Locate the black oxide stainless steel support plate by its rectangular shape It secures the front of the IntelliVue X3 Monitor inside the assembly HARDWARE KIT Thefollowinghardwareisprovidedfortheinstallation of the Bracket Pro Serie 71 9 Two 2 Nylon Patch Stainless Steel Flat Head Phillips Screws 10 32 x 1 2 9 Two 2 Black Oxide Stainless Steel...

Страница 17: ...stalled on the IntelliVue X3 Monitor from Philips 2 To install the IntelliVue X3 Monitor locate the main assembly 3 Align the medical device charging dock with the main assembly 4 Insert the medical device charging dock in the main assembly INSTALLATION GUIDE INSTALLATION OF THE INTELLIVUE X3 MONITOR INTO THE BRACKET ...

Страница 18: ...t Head Phillips 10 32 x 1 2 the top locking assembly and the front support plate 7 Align the top locking assembly and screw holes 8 Install the top locking assembly with the two 2 Black Oxide Stainless Steel Flat Head Phillips Screws 10 32 x 3 8 9 Align the front support plate and screw holes 10 Install the support plate with the two 2 Nylon Patch Stainless Steel Flat Head Phillips 10 32 x 1 2 NOT...

Страница 19: ...cal tools to install the screws 9 Do not overtighten the screws 12 Align the IntelliVue X3 Monitor with the right side of the bracket from a front view perspective 13 Press on the Red Quick Release Mechanism to insert the monitor into the bracket and gently slide into the charging dock 14 The Philips IntelliVue X3 Monitor is ready for transport once properly inserted into its bracket and the stret...

Страница 20: ...m the bracket press and hold the Red Quick Release Mechanism 2 While holding the Red Quick Release Mechanism press on the top button of the medical device 3 Take the handle of the IntelliVue X3 Monitor and slide it to the right to remove from the bracket CAUTION 9 Always remove the medical device by sliding it to the right Do not slide it forward OPERATION GUIDE ...

Страница 21: ...scoloration from continuous washing however degradation of the product s performance or functionality will not be affected due to power washing if cleaning instructions are properly followed The material used to manufacture the bracket is high grade aluminum it is very durable and resistant to corrosion however high levels of sodium or a high concentration of sodium or acid may prematurely corrode...

Страница 22: ... the product we recommend sanding the affected surface to remove the rust and then using the cleaning method presented in this guide once the rust is removed To clean the stained area use a solution of 1 4 Tablespoon of Sodium Thiosulfate in 1 pint 5 litre of warm water to clean the stained area Clean as soon as possible after staining occurs If stains are not immediately removed allow solution to...

Страница 23: ... contact your Technical Support Team at techsupport technimount com Check each routine and replace damaged or worn out parts if necessary Follow timetable below for maintenance either in months M or hours H in accordance with your Service s current maintenance practices and protocols ITEM ROUTINE 1 M OR 2 H 3 M OR 6 H 6 M OR 12 H 12 M OR 24 H Bracket 9 Inspect the bracket Inspect the screws Ensure...

Страница 24: ...Return to Table of Contents 24 BP71 UG 202108 01 www technimount com MAINTENANCE GUIDE INSPECTION AND MAINTENANCE RECORD PREVENTIVE MAINTENANCE PERFORMED BY DATE TIME ...

Страница 25: ...www technimount com BP71 UG 202108 01 25 Return to Table of Contents MAINTENANCE GUIDE TRAINING RECORD DATE TRAINING METHOD TRAINEE NAME BASIC TRAINING TRAINING UPDATE ...

Страница 26: ...t be individually available for purchase Please call Technimount Customer Service 1 888 639 2758 or at customerservice technimount com for availability and pricing DESCRIPTION PART NUMBER Bracket Pro Serie 71 330 10 PHX3 Two 2 Black Oxide Stainless Steel Flat Head Phillips Screws 10 32 x 3 8 TCM VF 999 131 Front Support Plate TCM 092 009 01 Top Locking Assembly TCM 092 009 02 Two 2 Nylon Patch Sta...

Страница 27: ...aced after the Warranty Period has expired the Warranty Period for the repair or replacement will expire three 3 months after the date of repair or replacement LIMITED RESPONSIBILITY AND WARRANTY The Limited Warranty does not apply to normal wear that should result from normal use It does not apply when the Hardware or any component is opened disassembled or repaired by someone not authorized by T...

Страница 28: ... 45 DAYS Product must be unused undamaged and in its original packaging The product return request must be provided in writing and it must be approved by TECHNIMOUNT prior to returning the product Returns will not be approved on modified or damaged item Charges may apply if damaged or missing items Customer is responsible for a 25 restocking fee PRIOR 60 DAYS Product must be unused undamaged and i...

Страница 29: ...the RMA form online at https www technimount com service support service support overview REQUIRED INFORMATION Serial number Invoice number Identification of the issue Upload the pictures of the issue Submit the form A confirmation of the receipt of the claim will be sent to you within 2 business days If you have not received a confirmation email by then please contact techsupport technimount com ...

Страница 30: ... matters most Technimount E M S Holding Inc 3770 Jean Marchand Street Suite 100 C Quebec QC G2C 1Y6 Canada T 1 888 639 2758 F 1 855 339 6351 technimount com info technimount com 2021 Technimount E M S Holding Inc All Rights Reserved Printed in Canada ...

Отзывы: