INTRODUCTION

PURPOSE OF THE DOCUMENT

This user guide is designed to assist you with the installation, operation and maintenance of the Technimount Bracket 

Pro Serie 121-GR1 for the Baxter Spectrum IQ Infusion Pump. 

PRODUCT DESCRIPTION

The Bracket Pro Serie 121-GR1 is a universal solution to mount the Spectrum IQ Infusion Pump from Baxter in different 

applications such as, on surface, a vertical system, stretcher or wall systems. It is designed to securely support and 

transport the Spectrum IQ Infusion Pump from Baxter in pre-hospital and hospital environments. The Bracket Pro 

Serie 121-GR1 provides a higher flexibility for different EMS/CCT protocols and applications. It is recommended for the 

safe transport of the infusion pump during inter-hospital transfers for neonatal critical care. 

INTENDED USE OF THE PRODUCT

The Bracket Pro Serie 121-GR1 is a mounting solution to securely transport the Baxter Spectrum IQ during inter-

hospital transfers. It is designed to be installed on the equipment as described in this user guide. The Bracket Pro 

Serie 121-GR1 is for crew who has received the appropriate training necessary to operate the equipment in the field 

according to its intended use as outlined in this user guide. Please read this user guide thoroughly before using this 

equipment. To ensure the safe operation of this equipment, it is highly recommended to train staff prior to use.

LIMITATION OF LIABILITY

Technimount has designed a system to attach and install medical equipment owned by the customer on an incubator 

transport stretcher manufactured by Stryker and involving or not a Dräger or other incubator brand.  

The  purchase  and  use  of  products  designed  by  Technimount  are  subject  to  this  limitation  of  liability  clause.  It  is 

important  to  understand  that,  as  Technimount  is  not  the  manufacturer  of  the  Stryker  stretcher  (or  other  brand) 

nor the manufacturer of the incubators (Dräger or other brand), Technimount cannot guarantee the resistance and 

durability of such stretchers and other equipment installed on it.

In addition, the mounting systems are designed by Technimount to install different medical equipment. Therefore, 

Technimount is not responsible for any damage that may result from the installation of multiple medical equipment 

on the stretcher. For example, risks related, but not limited to, potential stretcher overloading, tipping, interference 

between equipment, access restriction or other.

The Neonatal Stretcher System was developed by Technimount to meet an important market need, however, this 

transport system involves risks that remain under the sole responsibility of the customer. It is important to instruct 

your staff and partners to use Technimount products according to the safest practices and in accordance with the 

user's guide we provide. In addition, follow the safety guidance from the users guides from the manufacturers of 

the medical devices, incubators and transport stretcher system. Technimount will not be held responsible for any 

misuse of the product. Therefore, by confirming the purchase and accepting delivery of the transport system or any 

Technimount product, this constitutes confirmation of consent to this limitation of liability clause.

Содержание PRO 121-GR1 Series

Страница 1: ...BRACKET PRO SERIE 121 GR1 USER GUIDE ...

Страница 2: ...demark of Baxter In order to ensure continuous improvements to our products and services we invite you to communicate your comments to our Customer Service Department at customerservice technimount com LEGAL NOTICE Technologies CGC Inc or Technimount E M S Holding Inc or its affiliates are not expressly associated with the marketing distribution or sale of Baxter products The purchase and use of p...

Страница 3: ... your Technimount product its components or for any technical questions during the installation or maintenance processes please send an email to techsupport technimount com Please have the serial number of your Technimount product available as shown in the figure below when calling Technimount Technical Support Include the serial number in all written communications SERIAL NUMBER LOCATION CONTACT ...

Страница 4: ...Caution Note 12 NOTICE CERTIFICATION 14 INSTALLATION GUIDE 15 Removing the Packaging for Installation 15 Tools Required for Installation 15 Installation of the Spectrum IQ Infusion Pump into the bracket 16 OPERATION GUIDE 19 Removing the Spectrum IQ Infusion Pump from the bracket 19 MAINTENANCE GUIDE 20 Cleaning 20 Cleaning Process 20 Removal of Iodine Compounds 21 Preventive Maintenance 21 Inspec...

Страница 5: ...ABLE OF CONTENT RETURN POLICY 27 Return Policy 27 Prior to 30 Days 27 Prior 45 Days 27 Prior 60 Days 27 Return Authorization 27 Damaged Merchandise 28 Claim Process 28 Required Information 28 Findings and Conclusion 28 Questions about our Policy 28 ...

Страница 6: ... BP121 GR1 UG 202108 01 www technimount com INTRODUCTION SYMBOLS AND DEFINITIONS SYMBOL DESCRIPTION Warning and Caution special attention is required Consult accompanying documents Safe working load symbol and Load balance symbol ...

Страница 7: ...lt in death or serious injury It may also describe potential serious adverse reactions and safety hazards Caution Alerts the reader of a potentially hazardous situation which if not avoided may result in minor or moderate injury to the user or patient or damage to the equipment or other property This includes special care necessary for the safe and effective use of the device to avoid damage that ...

Страница 8: ...LLUSTRATION BRACKET PRO SERIE 121 GR1 Front View INTRODUCTION Side Blocks to Secure Medical Device Rubber Cushions Protecting the Medical Device into the Bracket High Density Aluminum with Black Anodized Finish Support Plate for Installation onto Rear Locking Block of Medical Device ...

Страница 9: ... PRO SERIE 121 GR1 CONTINUED Back View INTRODUCTION Integrated Handle for Ease of Transport Anti Rotation Micro Disc for Installation on Vertical and Wall Mounting Systems Red Quick Release Mechanism for Easy Installation and Removal of Medical Device Rubber Pads Protecting the Bracket when Placed on a Surface ...

Страница 10: ...ttach and install medical equipment owned by the customer on an incubator transport stretcher manufactured by Stryker and involving or not a Dräger or other incubator brand The purchase and use of products designed by Technimount are subject to this limitation of liability clause It is important to understand that as Technimount is not the manufacturer of the Stryker stretcher or other brand nor t...

Страница 11: ...atibility System Compatible with Technimount s Safety MD Transporter vertical Vertical Mounting System Micro Base Features Access to all Medical Device Monitors Connectors and Accessoriers Rubber Pads Protecting the Bracket when Placed on a Surface Bracket Built in Handle for Easy Transport Rubber Cushions Inside the Bracket to Protect Medical Device Red Quick Release Mechanism for Easy Installati...

Страница 12: ...ld fall during transport and may cause injury to the patient or operator and or damage to the product 9 Do not allow untrained staff to assist in the operation of the mounting system Untrained technicians staff can cause injury to the patient or themselves 9 Do not place additional equipment or items onto the bracket or mounts other than approved Technimount or components as this could damage the ...

Страница 13: ... possibly causing premature corrosion of critical components 9 When ordering it is important to identify on which mounting system you need to mount the bracket on as there are different systems for different applications ground 9 A maintenance program should be established for all Technimount equipment Preventive maintenance may need to be performed more frequently based on the level of use of the...

Страница 14: ...hnimount com WARNING The end user and administrator are responsible to validate regulations and standards for safety in their region in order to comply with applicable safety regulations Technimount is not responsible to inform the end user and or administrator of applicable legislation for safety in their area LEGAL NOTICE The purchase and use of products designed by Technimount are subject to th...

Страница 15: ...materials have been properly removed from the product s prior to installation 3 Identify all of the product components and hardware prior to starting the installation 4 The bracket must work properly before it is put into service 5 Refer to the identification of components at the beginning of this user guide if needed TOOLS REQUIRED FOR INSTALLATION No special tools or equipment are required to in...

Страница 16: ...ed on the Spectrum IQ Infusion Pump from Baxter 2 Locate the rear locking block of the medical device 3 Place the bracket on a stable surface 4 Locate the support plate of the bracket to be installed onto the rear locking block of the medical device INSTALLATION GUIDE INSTALLATION OF THE SPECTRUM IQ INFUSION PUMP INTO THE BRACKET ...

Страница 17: ...d Quick Release Mechanism at the back of the bracket 7 Align and slide the medical device rear locking block into the support plate of the bracket 8 Release the Red Quick Release Mechanism once the medical device is properly inserted and locked 9 Ensure that the medical device is properly inserted into the bracket by attempting to pull it out slightly and if it does not move it is now secure INSTA...

Страница 18: ... www technimount com 10 The Spectrum IQ Infusion Pump from Baxter is ready for transport once properly inserted into its bracket and the stretcher mounting system INSTALLATION OF THE SPECTRUM IQ INFUSION PUMP INTO THE BRACKET CONTINUED INSTALLATION GUIDE ...

Страница 19: ... remove the Spectrum IQ Infusion Pump from the bracket pull and hold the Red Quick Release Mechanism at the back of the bracket 2 Slide the rear locking block of the medical device up out of the support plate of the bracket 3 Release the Red Quick Release Mechanism once the medical device is released from the bracket OPERATION GUIDE ...

Страница 20: ...discoloration from continuous washing however degradation of the product s performance or functionality will not be affected due to power washing if cleaning instructions are properly followed The material used to manufacture the bracket is high grade aluminum it is very durable and resistant to corrosion however high levels of sodium or a high concentration of sodium or acid may prematurely corro...

Страница 21: ...of the product we recommend sanding the affected surface to remove the rust and then using the cleaning method presented in this guide once the rust is removed To clean the stained area use a solution of 1 4 Tablespoon of Sodium Thiosulfate in 1 pint 5 litre of warm water to clean the stained area Clean as soon as possible after staining occurs If stains are not immediately removed allow solution ...

Страница 22: ...ase contact your Technical Support Team at techsupport technimount com Check each routine and replace damaged or worn out parts if necessary Follow timetable below for maintenance either in months M or hours H in accordance with your Service s current maintenance practices and protocols ITEM ROUTINE 1 M OR 2 H 3 M OR 6 H 6 M OR 12 H 12 M OR 24 H Bracket 9 Inspect the bracket Inspect the screws Ens...

Страница 23: ...www technimount com BP121 GR1 UG 202108 01 23 Return to Table of Content MAINTENANCE GUIDE INSPECTION AND MAINTENANCE RECORD PREVENTIVE MAINTENANCE PERFORMED BY DATE TIME ...

Страница 24: ...Return to Table of Content 24 BP121 GR1 UG 202108 01 www technimount com MAINTENANCE GUIDE TRAINING RECORD DATE TRAINING METHOD TRAINEE NAME BASIC TRAINING TRAINING UPDATE ...

Страница 25: ...l currently available for purchase Some of the parts identified on the assembly drawing parts in this user guide may not be individually available for purchase Please call Technimount Customer Service 1 888 639 2758 or at customerservice technimount com for availability and pricing DESCRIPTION PART NUMBER Bracket Pro Serie 121 GR1 1510 10 BXIQ GR1 ...

Страница 26: ...placed after the Warranty Period has expired the Warranty Period for the repair or replacement will expire three 3 months after the date of repair or replacement LIMITED RESPONSIBILITY AND WARRANTY The Limited Warranty does not apply to normal wear that should result from normal use It does not apply when the Hardware or any component is opened disassembled or repaired by someone not authorized by...

Страница 27: ...R 45 DAYS Product must be unused undamaged and in its original packaging The product return request must be provided in writing and it must be approved by TECHNIMOUNT prior to returning the product Returns will not be approved on modified or damaged item Charges may apply if damaged or missing items Customer is responsible for a 25 restocking fee PRIOR 60 DAYS Product must be unused undamaged and ...

Страница 28: ...n the RMA form online at https www technimount com service support service support overview REQUIRED INFORMATION Serial number Invoice number Identification of the issue Upload the pictures of the issue Submit the form A confirmation of the receipt of the claim will be sent to you within 2 business days If you have not received a confirmation email by then please contact techsupport technimount co...

Страница 29: ......

Страница 30: ... it matters most Technimount E M S Holding Inc 3770 Jean Marchand Street Suite 100 C Quebec QC G2C 1Y6 Canada T 1 888 639 2758 F 1 855 339 6351 technimount com info technimount com 2021 Technimount E M S Holding Inc All Rights Reserved Printed in Canada ...

Отзывы: