OPERATING THE BRACKET ON THE SAFETY MD TRANSPORTER

INSTALLING THE BRACKET ONTO THE SAFETY MD TRANSPORTER

Operation Guide

1. 

Only Technimount brackets with an anti-rotation 

micro disc on the back can be inserted into the 

Micro Base located on the Safety MD Transporter.

2. 

Ensure  that  your  bracket  has  an  anti-rotation 

micro disc on the back to install the medical 

device onto the Safety MD Transporter.

3. 

While  using  both  hands,  slowly  insert  anti-

rotation disc located on the back of the bracket 

into the Micro Base.

WARNING

 

9

Ensure that the bracket is securely locked into 

the micro base before transport.

Back 

Anti-

Rotation 

Micro 

Disk

Содержание Bracket Pro Serie 110

Страница 1: ...BRACKET PRO SERIE 110 USER GUIDE ...

Страница 2: ...on of Technimount System or its affiliate companies Trademark Attributions Bracket Pro Serie is a registered trademark of Technimount System Monnal T60 is a registered trademark from Air Liquide Technimount System does not have a commercial relationship with Air Liquide Air Liquide does not promote or sell Technimount Products In order to ensure continuous improvements to our products and services...

Страница 3: ... G2C 1Y6 Canada www technimount com T 1 581 998 9820 F 1 855 339 6351 or customerservice technimount com techsupport technimount com NOTE Please have the serial number of your Technimount product available as shown in the figure below when calling Technimount Customer Service or Technical Support Include the serial number in all written communications SERIAL NUMBER LOCATION Contact Information ...

Страница 4: ...he Bracket onto the Safety MD Transporter 23 Rotating the Bracket on the Safety MD Transporter 24 REmoving the Bracket with the Medical Device from the Safety MD Transporter 25 General Operating Guidelines for the Safety Arm System 26 Operating the Bracket on the Safety Arm System 27 Installing the Bracket on the Standard Base 27 Rotating the Bracket on the Standard Surface Base 27 REmoving the Br...

Страница 5: ...rranty Options 37 three Warranty Options for Technimount Products 37 International Warranty Clause 37 RETURN POLICY 38 Return of Merchandise 38 Prior to 30 Days 38 Prior to 45 Days 38 Prior to 60 Days 38 Return Merchandise Authorization 38 Damaged Merchandise 38 SAE CERTIFICATION 39 ...

Страница 6: ...ents When used in emergency vehicles with a cot stretcher the Bracket Pro Serie 110 can be positioned on Technimount s Safety Arm System on a universal standard base on a Safety MD Transporter or with Technimount s Floor Mount or Wall Mount Systems These solutions provide a higher flexibility for different EMS CCT protocols and applications The Bracket Pro Serie 110 is compatible with the floor pl...

Страница 7: ...able of Contents Introduction POSSIBLE MOUNTING OPTIONS FOR THE BRACKET PRO SERIE 110 Safety MD Transporter Wall Mount System Ground Ambulance in Europe Technimount Stretcher Safety Arm System Air Ambulance Floor Mount Technimount Universal Standard Base ...

Страница 8: ...ts 8 BP110 UG 202002 R01 www technimount com Introduction SYMBOLS AND DEFINITIONS SYMBOL DESCRIPTION Caution special attention is required Consult accompanying documents Safe working load symbol Pinch Point Load balance symbol ...

Страница 9: ... serious injury It may also describe potential serious adverse reactions and safety hazards Caution Alerts the reader of a potentially hazardous situation which if not avoided may result in minor or moderate injury to the user or patient or damage to the equipment or other property This includes special care necessary for the safe and effective use of the device to avoid damage that may occur as a...

Страница 10: ... Feet to Protect when Placed on the Floor or Ground High Density Aluminum with Silver Anodized Finish Universal Standard Bottom Disc Compatible with all of Technimount s Mounting Solutions Back Plate 2 is Installed after the Junction Plate and goes Under the Device Handle Main Assembly on Which Plates and Medical Device are Installed Retractable Back Hooks for Temporary Transfer Between Hospital a...

Страница 11: ...ed for Vertical Support on Different Wall or Arm Systems Junction Plate 1 is Installed First onto the Monnal T60 Back Side Back Plate 2 is Installed after the Junction Plate and goes Under the Device Handle Acetal Feet to Protect when Placed on the Floor or Ground Universal Standard Bottom Disc Compatible with all of Technimount s Mounting Solutions High Density Aluminum with Silver Anodized Finis...

Страница 12: ...ning System Device Retained on Platform with Junction and Back Plates Retaining System 2 Locking Discs Standard Bottom Section Anti Rotation Back Micro Disc Transportation Compatibility System Compatible with Technimount s Standard Surface Base Compatible with Technimount s Stretcher Safety Arm System For Stryker Cots PowerPro XT and Mx Pro Compatible with the Floor Mount Platform Flight Compatibl...

Страница 13: ...Directive 1999 5 EC and SAE J3043 A copy of the original declaration of conformity can be obtained by contacting Technimount System s Regulatory Affairs Department Technimount System C O Regulatory Affairs info technimount com 1 581 998 9820 WARNING End User Administrator is responsible to validate regulations and standards for safety in their region in order to comply with applicable safety regul...

Страница 14: ...roperly the medical device could fall during transport and may cause injury to the patient or operator and or damage to the product 9 Do not allow untrained staff to assist in the operation of the mounting system Untrained technicians staff can cause injury to the patient or themselves 9 Do not place additional equipment or items onto the Bracket or mounts other than approved Technimount Systems o...

Страница 15: ...using premature corrosion of critical components 9 When ordering it is important to identify on which mounting system you need to mount the bracket on as their are different systems for different EMS applications e g EMS ground or air mounting systems 9 A maintenance program should be established for all Technimount equipment Preventive maintenance may need to be performed more frequently based on...

Страница 16: ...s at the beginning of this user guide if needed TOOLS REQUIRED FOR INSTALLATION Below are the basic tools required for installation If you have any questions regarding the installation or need assistance please contact our Technical Support team at techsupport technimount com 1 Allen Key 1 8 in 2 Allen Key 4mm NOTE 9 Electrical tools are not recommended as there is a potential risk of damage to th...

Страница 17: ...particluar version of the bracket cannot be used without the bag 2 Remove the Bag 3 Locate the plastic cover with the hooks on the back of the unit 4 The cover and metal plate with hooks will be replaced with Technimount s bracket and hooks 5 Remove plastic cover from the back of the unit by unscrewing all 4 screws Installation Guide INSTALLATION OF THE BRACKET ONTO THE MONNAL VENTILATOR ...

Страница 18: ... Locate the 4 screws on the back metal plate 7 Remove the back plate with hooks by removing all 4 screws 8 Remove the metal plate with hooks completely 9 Set aside the cover and back metal plate for use without the mounting bracket 10 Place both Junction Plate 1 and Back Plate onto the back of the Monnal T60 ventilator Installation Guide ...

Страница 19: ...tion Plate first onto the the Back of the Monnal T60 ventilaor 12 Lift the top handle of the ventilator 13 Place the Back Plate onto the Junction Plate next and ensure it is placed under the handle 14 Put handle back down over top of the Back Plate 15 Place washers over the 4 holes 16 Insert all 4 screws provided for the installation of the back plates Show same view with fluid pole ...

Страница 20: ...Guide 17 Replace the bag back onto the Monnal T60 ventilator with back plates installed 18 The device is now ready to be installed onto the main assembly 19 There are 3 screws to be installed on each side of the back plates onto the main assembly 20 Ensure to adjust all 6 screws before tightening 21 Tighten all 6 screws while alternating screwsheads ...

Страница 21: ...pproved mounting systems and products by Technimount USING THE BACK HOOKS 1 To open the hooks open one hook at a time by pulling the hook towards you 2 To close the hooks close one hook at a time by pushing the hook back into closed position WARNING The Bracket Pro Serie 110 Back Hooks are meant to be used only for the temporary transfer between the ambulance stretcher and hospital These hooks CAN...

Страница 22: ...NES FOR THE SAFETY MD TRANSPORTER 9 Use the Safety MD Transporter only as described in the User Guide 9 Read all the labels and instructions on the product before using the Safety MD Transporter 9 Always inspect the Micro Base and the Safety MD Transporter for any issue or damage before every use 9 Installing or removing the Safety MD Transporter requires a minimum of one 1 trained operator 9 Do n...

Страница 23: ...sc on the back can be inserted into the Micro Base located on the Safety MD Transporter 2 Ensure that your bracket has an anti rotation micro disc on the back to install the medical device onto the Safety MD Transporter 3 While using both hands slowly insert anti rotation disc located on the back of the bracket into the Micro Base WARNING 9 Ensure that the bracket is securely locked into the micro...

Страница 24: ...RANSPORTER CONTINUED INSTALLING THE BRACKET ONTO THE SAFETY MD TRANSPORTER CONTINUED Operation Guide 4 A Bracket Pro Serie 110 installed on the Safety MD Transporter ROTATING THE BRACKET ON THE SAFETY MD TRANSPORTER 1 To rotate the medical device 360 turn the Safety MD Transporter clockwise or counter clockwise ...

Страница 25: ...TER CONTINUED REMOVING THE BRACKET WITH THE MEDICAL DEVICE FROM THE SAFETY MD TRANSPORTER 1 To remove the bracket from the Safety MD Transporter press the red quick release button located on the back Micro Base 2 While holding the red quick release button lift the bracket upwards until removed and release the red quick release button ...

Страница 26: ...ded while the patient is on the cot stretcher 9 Use the Safety Arm System only as described in its User Guide 9 Read all the labels and instructions on the product before using the Safety Arm System 9 Always inspect the Clamp Block Safety Pin Lock Pin and Surface Base before every use 9 Installing or removing the Safety Arm System requires a minimum of one 1 trained operator 9 Do not remove the Sa...

Страница 27: ...ally from the front of the base 3 Ensure the bracket is locked securely in the Standard Surface base before manipulating the device or transporting the stretcher ROTATING THE BRACKET ON THE STANDARD SURFACE BASE 1 To rotate the medical device 360 turn the bracket inside the standard surface base clockwise or counter clockwise to use the device in the desired position OPERATING THE BRACKET ON THE S...

Страница 28: ...back Standard Base 2 While holding the red quick release button slide outwards horizontally to remove from the base USING THE BACK HOOKS ON THE STRETCHER OR HOSPITAL BED 1 Open back hooks one at a time by pulling towards you 2 Place onto the side rail of the stretcher or hospital bed WARNING The Bracket Pro Serie 110 Back Hooks are meant to be used only for the temporary transfer between the ambul...

Страница 29: ...ferent Models Available refer to Customer Service WARNING Do not modify any components of these system Modifying the products can cause unpredictable operation resulting in injury to the patient or operator NOTE Technimount reserves the right to change Part Numbers and Products without notice Please refer to Customer Service to ensure product part number availability For any replacement parts or f...

Страница 30: ... and ensure that the product does not stay wet longer than the cleaner manufacturer s guidelines for proper disinfecting WARNING 9 When cleaning always use appropriate personal protection equipment PPE based on established protocols e g gloves eyewear etc CAUTION 9 Do not steam clean or use ultrasonic cleaners on the system or any of its components 9 Do not immerse the metal parts components in wa...

Страница 31: ...rvice WARNING 9 Failure to properly clean contaminated parts or components will increase the risk of exposure to blood borne pathogens and may cause injury to the patient or the operator PREVENTIVE MAINTENANCE A preventive and regular maintenance program should be established for all Technimount equipment Preventive maintenance may be required more frequently based on the usage level of the produc...

Страница 32: ...rform these maintenance inspections or at what interval to perform these inspections please contact your Technical Support Team at techsupport technimount com Check each routine and replace damaged or worn out parts if necessary Follow table below in accordance to the timetable whichever comes first ITEM ROUTINE 1 M OR 2 H 3 M OR 6 H 6 M OR 12 H 12 M OR 24 H Bracket 9 Inspect Bracket Inspect the s...

Страница 33: ...www technimount com BP110 UG 202002 R01 33 Return To Table of Contents Maintenance Guide INSPECTION AND MAINTENANCE RECORD PREVENTIVE MAINTENANCE PERFORMED BY DATE TIME ...

Страница 34: ... To Table of Contents 34 BP110 UG 202002 R01 www technimount com Maintenance Guide TRAINING RECORD TRAINING DATE TRAINING METHOD USER GUIDE IN SERVICE IN CLASS ETC TRAINEE NAME BASIC TRAINING TRAINING UPDATE ...

Страница 35: ...er guide may not be individually available for purchase Please call Technimount Customer Service or Technical Support 1 581 998 9820 or at customerservice technimount com or techsupport technimount com for availability and pricing DESCRIPTION PART NUMBER Anti Rotation Back Disc TCM 052 006 Standard Bottom Disc 926 00 SS Acetal Feet TCM 032 082 Label Brand Name 942 00 UN Label Instructions in Engli...

Страница 36: ... repaired or replaced according to the Limited Warranty without charge to the purchaser for either parts or labor The parts may be repaired or replaced with either new or refurbished parts The product may be replaced for a new or refurbished product For this Limited Warranty refurbished means parts and products which have been returned to factory specifications If the Hardware is repaired or repla...

Страница 37: ...at affect product performance and customer satisfaction for a period of two 2 years following the end date of the original warranty Technimount s obligation under this warranty is limited to supplying replacement parts and labor for any component or option of this system that is found to be defective at Technimount s sole discretion 3 Three year 3 additional warranty after the original warranty fo...

Страница 38: ...r service department is responsible for approving any merchandise return and will provide an RMA Return Merchandise Authorization number to be printed on any returned merchandise Technimount reserves the right to charge shipping and restocking fees on returned items Customized modified or discontinued items not subject to return DAMAGED MERCHANDISE ICC Regulations require that claims for damaged m...

Страница 39: ...www technimount com BP110 UG 202002 R01 39 Return To Table of Contents SAE Certification ...

Страница 40: ...chnimount System Brand of Technologies CGC Corporate Headquarters 3770 Jean Marchand Street Suite 100 Quebec QC G2C 1Y6 Canada T 1 581 998 9820 F 1 855 339 6351 technimount com info technimount com Copyright 2020 Technimount System All Rights Reserved Printed in Canada ...

Отзывы: