Introduction

SYMBOLS AND DEFINITIONS

SYMBOL

DESCRIPTION

Caution,  special  attention  is  required.  Consult  accompanying 

documents

Safe working load symbol

Pinch Point

Load balance symbol

Содержание BRACKET PRO 105 Series

Страница 1: ...BRACKET PRO SERIE 105 USER GUIDE ...

Страница 2: ...hnimount System or its affiliate companies Trademark Attributions Bracket Pro Serie is a registered trademark of Technimount System EnVe ReVel is a registered trademark from Carefusion Vyaire Technimount System does not have a commercial relationship with Carefusion Vyaire Carefusion Vyaire does not promote or sell Technimount Products In order to ensure continuous improvements to our products and...

Страница 3: ...Canada www technimount com T 1 581 998 9820 F 1 855 339 6351 or customerservice technimount com techsupport technimount com NOTE Please have the serial number of your Technimount product available as shown in the figure below when calling Technimount Customer Service or Technical Support Include the serial number in all written communications SERIAL NUMBER LOCATION Contact Information S N C 45 XXX...

Страница 4: ...he Bracket on the Safety MD Transporter 21 Installing the Bracket onto the Safety MD Transporter 21 Rotating the Bracket on the Safety MD Transporter 22 REmoving the Bracket with the Medical Device from the Safety MD Transporter 23 General Operating Guidelines for the Safety Arm System 24 Operating the Bracket on the Safety Arm System 25 Installing the Bracket on the Standard Base 25 Rotating the ...

Страница 5: ...rranty Options 35 three Warranty Options for Technimount Products 35 International Warranty Clause 35 RETURN POLICY 36 Return of Merchandise 36 Prior to 30 Days 36 Prior to 45 Days 36 Prior to 60 Days 36 Return Merchandise Authorization 36 Damaged Merchandise 36 SAE CERTIFICATION 37 ...

Страница 6: ... environments When used in emergency vehicles with a cot stretcher the Bracket Pro Serie 105 can be positioned on Technimount s Safety Arm System on a universal standard base on a Safety MD Transporter or with Technimount s Floor Mount or Wall Mount Systems These solutions provide a higher flexibility for different EMS CCT protocols and applications The Bracket Pro Serie 105 is compatible with the...

Страница 7: ...Table of Contents Introduction POSSIBLE MOUNTING OPTIONS FOR THE BRACKET PRO SERIE 105 Safety MD Transporter Wall Mount Systems EU Technimount Stretcher Safety Arm System Floor Mount Air Ambulance Technimount Universal Standard Base Wall Mount Systems NA ...

Страница 8: ...ts 8 BP105 UG 202002 R01 www technimount com Introduction SYMBOLS AND DEFINITIONS SYMBOL DESCRIPTION Caution special attention is required Consult accompanying documents Safe working load symbol Pinch Point Load balance symbol ...

Страница 9: ... serious injury It may also describe potential serious adverse reactions and safety hazards Caution Alerts the reader of a potentially hazardous situation which if not avoided may result in minor or moderate injury to the user or patient or damage to the equipment or other property This includes special care necessary for the safe and effective use of the device to avoid damage that may occur as a...

Страница 10: ...hen Placed on the Ground Side Arms to Hold Unit Securely in Place Universal Standard Bottom Disc Compatible with all of Technimount s Mounting Solutions High Density Aluminum Aeronautical Quality Manufacturing and Silver Anodized Finish Opening at the Top for the Handle of the Medical Device Top Support is Installed over the Medical Device to Secure it inside the Bracket ...

Страница 11: ... Disc is used for Vertical Support on Different Wall or Arm Systems Acetal Feet to Protect the Disc when Placed on the Ground Universal Standard Bottom Disc Compatible with all of Technimount s Mounting Solutions High Density Aluminum Aeronautical Quality Manufacturing and Silver Anodized Finish Top Support is Installed over the Medical Device to Secure it inside the Bracket ...

Страница 12: ...ight FAA FAR DOT 27 561 DOT 27 562 up to 20G in process Medical Device Retaining System Device retained on main assembly with no screws attached to the Device Retaining System 2 Locking Discs Standard Bottom Section Back Anti Rotation Micro Disc Transportation Compatibility System Compatible with Technimount s Standard Surface Base Compatible with Technimount s Stretcher Safety Arm System For Stry...

Страница 13: ...of the Directive 1999 5 EC and SAE J3043 A copy of the original declaration of conformity can be obtained by contacting Technimount System s Regulatory Affairs Department Technimount System C O Regulatory Affairs info technimount com 1 581 998 9820 WARNING EndUser Administratorrisresponsibletovalidateregulationsandstandardsforsafetyintheirregion inordertocomply with applicable safety regulations T...

Страница 14: ...roperly the medical device could fall during transport and may cause injury to the patient or operator and or damage to the product 9 Do not allow untrained staff to assist in the operation of the mounting system Untrained technicians staff can cause injury to the patient or themselves 9 Do not place additional equipment or items onto the Bracket or mounts other than approved Technimount Systems o...

Страница 15: ...using premature corrosion of critical components 9 When ordering it is important to identify on which mounting system you need to mount the bracket on as there are different systems for different EMS applications e g EMS ground or air mounting systems 9 A maintenance program should be established for all Technimount equipment Preventive maintenance may need to be performed more frequently based on...

Страница 16: ...rior to starting the installation 4 The Bracket System must work properly before being put into service 5 Refer to the identification of components at the beginning of this user guide if needed TOOLS REQUIRED FOR INSTALLATION Below are the basic tools required for installation If you have any questions regarding the installation or need assistance please contact our Technical Support team at techs...

Страница 17: ...he Bracket Pro Serie 105 is designed to be installed on the EnVe ReVel ventilator 2 Place the ventilator and the bracket onto a stable surface 3 Insert the EnVe or ReVel ventilator into the bracket Installation Guide INSTALLATION OF THE BRACKET ONTO THE ENVE REVEL VENTILATOR ...

Страница 18: ...ents INSTALLATION OF THE BRACKET ONTO THE ENVE REVEL VENTILATOR CONTINUED 4 Place the top support over the medical device 5 Apply Blue Loctite 243 on the four 4 10 32 x 1 2 in hexagonal screws 6 Tighten all four 4 screws while alternating screwheads Installation Guide ...

Страница 19: ...www technimount com BP105 UG 202002 R01 19 Return To Table of Contents Installation Guide INSTALLATION OF THE BRACKET ONTO THE ENVE REVEL VENTILATOR CONTINUED ...

Страница 20: ...NES FOR THE SAFETY MD TRANSPORTER 9 Use the Safety MD Transporter only as described in the User Guide 9 Read all the labels and instructions on the product before using the Safety MD Transporter 9 Always inspect the Micro Base and the Safety MD Transporter for any issue or damage before every use 9 Installing or removing the Safety MD Transporter requires a minimum of one 1 trained operator 9 Do n...

Страница 21: ...sc on the back can be inserted into the Micro Base located on the Safety MD Transporter 2 Ensure that your bracket has an anti rotation micro disc on the back to install the medical device onto the Safety MD Transporter 3 While using both hands slowly insert anti rotation disc located on the back of the bracket into the Micro Base WARNING 9 Ensure that the bracket is securely locked into the micro...

Страница 22: ... TRANSPORTER CONTINUED INSTALLING THE BRACKET ONTO THE SAFETY MD TRANSPORTER CONTINUED Operation Guide 4 A Bracket Pro Serie 105 installed on the Safety MD Transporter ROTATING THE BRACKET ON THE SAFETY MD TRANSPORTER 1 To rotate the medical device turn the Safety MD Transporter clockwise or counter clockwise ...

Страница 23: ...TER CONTINUED REMOVING THE BRACKET WITH THE MEDICAL DEVICE FROM THE SAFETY MD TRANSPORTER 1 To remove the bracket from the Safety MD Transporter press the red quick release button located on the back Micro Base 2 While holding the red quick release button lift the bracket upwards until removed and release the red quick release button ...

Страница 24: ...ded while the patient is on the cot stretcher 9 Use the Safety Arm System only as described in its User Guide 9 Read all the labels and instructions on the product before using the Safety Arm System 9 Always inspect the Clamp Block Safety Pin Lock Pin and Surface Base before every use 9 Installing or removing the Safety Arm System requires a minimum of one 1 trained operator 9 Do not remove the Sa...

Страница 25: ...ally from the front of the base 3 Ensure the bracket is locked securely in the Standard Surface base before manipulating the device or transporting the stretcher ROTATING THE BRACKET ON THE STANDARD SURFACE BASE 1 To rotate the medical device 360 turn the bracket inside the standard surface base clockwise or counter clockwise to use the device in the desired position OPERATING THE BRACKET ON THE S...

Страница 26: ...ET ON THE SAFETY ARM SYSTEM CONTINUED REMOVING THE BRACKET FROM THE STANDARD SURFACE BASE 1 To remove the bracket from the Safety MD Transporter press the red quick release button located on the back Standard Base 2 While holding the red quick release button slide outwards horizontally to remove from the base ...

Страница 27: ...ferent Models Available refer to Customer Service WARNING Do not modify any components of these system Modifying the products can cause unpredictable operation resulting in injury to the patient or operator NOTE Technimount reserves the right to change Part Numbers and Products without notice Please refer to Customer Service to ensure product part number availability For any replacement parts or f...

Страница 28: ... and ensure that the product does not stay wet longer than the cleaner manufacturer s guidelines for proper disinfecting WARNING 9 When cleaning always use appropriate personal protection equipment PPE based on established protocols e g gloves eyewear etc CAUTION 9 Do not steam clean or use ultrasonic cleaners on the system or any of its components 9 Do not immerse the metal parts components in wa...

Страница 29: ...rvice WARNING 9 Failure to properly clean contaminated parts or components will increase the risk of exposure to blood borne pathogens and may cause injury to the patient or the operator PREVENTIVE MAINTENANCE A preventive and regular maintenance program should be established for all Technimount equipment Preventive maintenance may be required more frequently based on the usage level of the produc...

Страница 30: ...rform these maintenance inspections or at what interval to perform these inspections please contact your Technical Support Team at techsupport technimount com Check each routine and replace damaged or worn out parts if necessary Follow table below in accordance to the timetable whichever comes first ITEM ROUTINE 1 M OR 2 H 3 M OR 6 H 6 M OR 12 H 12 M OR 24 H Bracket 9 Inspect Bracket Inspect the s...

Страница 31: ...www technimount com BP105 UG 202002 R01 31 Return To Table of Contents Maintenance Guide INSPECTION AND MAINTENANCE RECORD PREVENTIVE MAINTENANCE PERFORMED BY DATE TIME ...

Страница 32: ... To Table of Contents 32 BP105 UG 202002 R01 www technimount com Maintenance Guide TRAINING RECORD TRAINING DATE TRAINING METHOD USER GUIDE IN SERVICE IN CLASS ETC TRAINEE NAME BASIC TRAINING TRAINING UPDATE ...

Страница 33: ...er guide may not be individually available for purchase Please call Technimount Customer Service or Technical Support 1 581 998 9820 or at customerservice technimount com or techsupport technimount com for availability and pricing DESCRIPTION PART NUMBER Anti Rotation Back Disc TCM 052 006 Standard Bottom Disc 926 00 SS Acetal Feet TCM 032 082 Label Brand Name 942 00 UN Label Instructions in Engli...

Страница 34: ... repaired or replaced according to the Limited Warranty without charge to the purchaser for either parts or labor The parts may be repaired or replaced with either new or refurbished parts The product may be replaced for a new or refurbished product For this Limited Warranty refurbished means parts and products which have been returned to factory specifications If the Hardware is repaired or repla...

Страница 35: ...at affect product performance and customer satisfaction for a period of two 2 years following the end date of the original warranty Technimount s obligation under this warranty is limited to supplying replacement parts and labor for any component or option of this system that is found to be defective at Technimount s sole discretion 3 Three year 3 additional warranty after the original warranty fo...

Страница 36: ...issing items RETURN MERCHANDISE AUTHORIZATION Technimount s customer service department is responsible for approving any merchandise return and will provide an RMA Return Merchandise Authorization number to be printed on any returned merchandise Technimount reserves the right to charge shipping and restocking fees on returned items Customized modified or discontinued items not subject to return DA...

Страница 37: ...www technimount com BP105 UG 202002 R01 37 Return To Table of Contents SAE Certification ...

Страница 38: ...chnimount System Brand of Technologies CGC Corporate Headquarters 3770 Jean Marchand Street Suite 100 Quebec QC G2C 1Y6 Canada T 1 581 998 9820 F 1 855 339 6351 technimount com info technimount com Copyright 2020 Technimount System All Rights Reserved Printed in Canada ...

Отзывы: