![Technika TEG95DUA Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/technika/teg95dua/teg95dua_instructions-for-use-and-installation_1069192037.webp)
Gas Conversion (U-LPG to NG) Hob Burners
Parts needed...
- NG Regulator
- NG
- Auxiliary Jet Ø0.88mm
- Semi-Rapid Jet Ø1.16mm
- Rapid Jet Ø1.50mm
- Wok Jet Ø1.75mm
Converting to a different gas type
When converting from Universal LPG to Natural Gas ensure that the
ULPG test point is removed and replaced with the AGA Approved NG
Regulator supplied in the conversion kit. The test point pressure must
be adjusted to 1.00kPa with the largest burner operating on maximum
flame.
Changing the jets
1. Remove pan supports, burner heads and caps.
2. Use a size 7 socket wrench to unscrew and
remove the jets, replacing them with those
supplied in the conversion kit. Ensure you use the
correct jet for the corresponding burner.
3. Reassemble the burner heads, caps and pan
supports.
4. Fit the Gas type label supplied in the conversion
kit next to the gas connection point and remove
the existing label.
Setting the minimum level
1. Light one of the burners and turn the tap to
minimum flame.
2. Remove the corresponding control knob.
3. Use a thin blade screwdriver to turn the by-pass
screw located above left of the gas valve shaft
as shown right. Turn the by-pass screw fully
clockwise then turn it anti-clockwise 1 turn for
the Wok, 3/4 turn for the Rapid, ½ turn for the
Semi-Rapid and 3/8 turn for the Auxiliary. The
result should be a small, stable flame which is
uniform around the entire burner ring. If not, turn
the by-pass screw anti-clockwise until
satisfied with the flame.
4. Check that the burner does not go out when the
tap is turned quickly from the maximum to the
minimum position.
5. Repeat for each burner.
Gas Type label
37