36
Gas Conversion (NG to U-LPG) Hob Burners
Parts needed...
- Test Point Assembly
- U
- Auxiliary Jet Ø0.53mm
- Semi-Rapid Jet Ø0.68mm
- Rapid Jet Ø0.88mm
- Wok Jet Ø1.00mm
Converting to a different gas type
When converting from Natural Gas to Universal LPG ensure that the
NG regulator is removed and replaced with the Test Point Assembly
supplied in the conversion kit. An AGA Approved gas regulator suitable
for a supply pressure of 2.75kPa should be part of the gas tank supply
and the test point pressure must be adjusted to 2.75kPa.
Changing the jets
1. Remove pan supports, burner heads and caps.
2. Use a size 7 socket wrench to unscrew and
remove the jets, replacing them with those
supplied in the conversion kit. Ensure you use
the correct jet for the corresponding burner.
3. Reassemble the burner heads, caps and pan
supports.
4. Fit the Gas type label supplied in the conversion
kit next to the gas connection point and remove
the existing label.
Setting the minimum level on the hob burners
1. Light one of the burners and turn the tap to
minimum flame.
2. Remove the corresponding control knob.
3. Use a thin blade screwdriver to turn the by-pass
screw located above left of the gas valve shaft
as shown right. Turn the by-pass screw fully
clockwise. The result should be a small, stable
flame which is uniform around the entire burner
ring. If not, turn the by-pass screw anti-clockwise
until satisfied with the flame.
4. Check that the burner does not go out when the
tap is turned quickly from the maximum to the
minimum position.
5. Repeat for each burner.