2 Before Repair and Adjustment
TOP
PREVIOUS
NEXT
Disconnect AC power, discharge Power Supply Capacitors C1702 through a 10
Ω
, 5 W resistor to
ground. DO NOT SHORT-CIRCUIT DIRECTLY (with a screw driver blade, for instance), as this may
destroy solid state devices.
After repairs are completed, restore power gradually using a variac, to avoid over current.
Current consumption at AC 120 V, 60 Hz in NO SIGNAL mode should be 750~1050 mA.
•@