Advanced Settings & Calibration modes
Fan
Heater
Temp
R/h
Htr
Min
Max
Fan
Power
Evolution
Humidity
Temperature
Digital Fan Speed Controller
DOWN
UP
1.Press and hold
Min/Max and R/h
button
down during power up.
2.Once powered up and displaying
- - - - - - release buttons.
3.The Humidity display on the right LED
window will now constantly flash on/off
every second or so to show that humidity
control has now been disabled and will only
show live readings and will no longer
control the fans.
Fan
Heater
Temp
R/h
Htr
Min
Max
Fan
Power
Evolution
Humidity
Temperature
Digital Fan Speed Controller
DOWN
UP
Fan
Heater
Temp
R/h
Htr
Min
Max
Fan
Power
Evolution
Humidity
Temperature
Digital Fan Speed Controller
DOWN
UP
1
2
3
release
once the
display shows
- - - - - -
Humidity LED will flash every second to
show it is now set to “humidity ignore” mode.
Humidity Ignore Mode
This mode can be useful in winter or wet
season if external humidity is above
desired and temperature is below.
hold down
min/max & htr
button
power on
your
controller
18
Содержание Evolution