Technical Manual LDK 4628 - Operational Control Panel

3

Symbol Colour

Explanation

Red

High voltage terminal at which a
voltage, with respect to an other
terminal, exists or may be
adjusted to 1000V or more.

Yellow/Black

Live part.

Yellow/Black

This marking indicates that the
operator must refer to an
explanation in the Instruction
Manual, or that a specific
component must be replaced by
the component specified in the
documentation for safety
reasons.

White/Black

Protective earth (ground)
terminal.

Cathode ray tubes

Components marked 

 on the circuit diagram are critical

for safety and include those specified to comply with X-ray
emission  standards for units using cathode ray tubes and
those specified for compliance with various regulations
regarding spurious radiation emission.

When servicing units that use cathode ray tubes (CRTs),
the cathode ray tubes themselves, the high voltage circuits
and related circuits are specifically chosen so that they
comply with recognized codes pertaining to X-ray emission.

Consequently, when servicing, replace the cathode ray
tubes and other parts with specified parts only. Do not
attempt to modify these circuits as any unauthorized
modification can increase the high voltage value and
cause X-ray emission from the cathode ray tube.

Handle the cathode ray tube only when wearing shatterproof
goggles and after discharging the high voltage completely.

Earthing

The rear of a CPU has two separate screw terminals for
protective earth 

 (PE) and video earth 

 (VE).

These are normally connected by a metal strap. The
protective earth terminal is internally connected to the
protective earth conductor of the power cable. If required,
the central earth connection wire of the studio can be
connected to terminal PE.

In normal circumstances the connection between the
protective earth and the video earth should not be broken.

The metal strap may be removed only if the studio (or OB
van) is equipped with separate protective and video earth
systems. Under these circumstances the video earth
terminal must be connected to the central functional earth
potential (video earth) of the studio. This earth potential
should have functional protective and noiseless earth
(FPE) qualities as stated in the VDE regulation 0800/part2.
A low impedance interconnection of both earth conductors
must be provided at the central studio earthing point.

WARNING

THE UNIT MUST ALWAYS BE CONNECTED TO

PROTECTIVE EARTH.

VE

PE

Metal
strap

Mains Lead Wiring for UK Users
The wires in the mains lead are coloured in accordance
with the following code:

GREEN AND YELLOW

-

EARTH

BLUE

-

NEUTRAL

BROWN

-

LIVE

As the colours of the wires in the mains lead of this
apparatus may not correspond with the coloured markings
identifying the terminals in your plug proceed as follows:
• The wire coloured GREEN AND YELLOW must be

connected to the terminal on the plug marked with the
letter E or by the safety earth symbol   or coloured
GREEN or GREEN AND YELLOW.

• The wire coloured BROWN must be connected to the

terminal marked with the letter L or coloured RED.

• The wire coloured BLUE must be connected to the

terminal marked with the letter N or coloured BLACK.

Ensure that your equipment is connected correctly - if you
are in any doubt consult a qualified electrician.

Содержание LDK 4628/01

Страница 1: ... Standard Store On air Auto iris F Number Extender Cam select 4 1 15 8 Iris Free Call Preview Centre Range Series 9000 OCP Cam pwr Pan lock OCP pwr Camera Base St Gen lock Triax Non standard Exposure Gamma Monitoring 1 2 Var Lin Variable R G B Sup CVBS Seq Saturation Wh clip Blk str Blk str Saw Gamma Flare Contour Var V level Level Lev dep Var Bars Contour Auto Auto wh Auto blk Point Slope Knee Pr...

Страница 2: ...modification au cours de l évolution technique Thomson Multimedia Broadcast Solutions 2002 We Thomson Broadcast Solutions Nederland B V Kapittelweg 10 4827 HG Breda The Netherlands declare under our sole responsibility that this product is in compliance with the following standards EN60065 EN55103 1 EN55103 2 following the provisions of a the Safety Directives 73 23 EEC and 93 68 EEC b the EMC Dir...

Страница 3: ... Contents Safety Summary 2 Cautions and Warnings 2 Earthing 3 Packing Unpacking 4 Opening the Operational Control Panel 5 Mounting in a Desk 6 Mounting in a 19 inch Rack 8 Internally Selectable Functions 10 Replacing the fuses 11 Interconnections 12 Two wire Data Control Bus 14 Connectors and Cables 15 Dimensions 17 ...

Страница 4: ...ings indicate danger that requires correct procedures orpracticestopreventdeathorinjurytopersonnel Cautions indicate procedures or practices that should be followed to prevent damage or destruction to equipment or property WARNING THE CURRENT AND VOLTAGES PRESENT IN THIS EQUIPMENT ARE DANGEROUS ALL PERSONNEL MUST AT ALL TIMES FOLLOW THE SAFETY REGULATIONS ALWAYS DISCONNECT POWER BEFORE REMOVING CO...

Страница 5: ...y a metal strap The protective earth terminal is internally connected to the protective earth conductor of the power cable If required the central earth connection wire of the studio can be connected to terminal PE In normal circumstances the connection between the protective earth and the video earth should not be broken The metal strap may be removed only if the studio or OB van is equipped with...

Страница 6: ...g returned to Thomson Multimedia Broadcast Solutions for servicing try to use the containers and materials of the original packaging Attach a tag indicating the type of service required returnaddress modelnumber fullserialnumberand the return number which will be supplied by your Thomson Multimedia Broadcast Solutions service centre If the original packing can no longer be used the following gener...

Страница 7: ...02 33 2 Technical Manual LDK 4628 Operational Control Panel 5 Opening the Operational Control Panel ...

Страница 8: ...Flare Contour Var V level Level Lev dep Var Bars Contour Auto Auto wh Auto blk Point Slope Knee 1 Clr 2 3 4 5 6 7 8 Cap Aw 1 Aw 2 7500 K 5600 K 3200 K 0 Gain Black Scene file 1 2 3 Standard Store On air Auto iris F Number Extender Cam select 4 1 15 M black Iris 8 Free Call Preview Centre Range Col Temp Gain Filter Hole in desk required 350 7 mm x 106 3 mm 1 Remove upper panel by loosening screws a...

Страница 9: ...our Auto Auto wh Auto blk Point Slope Knee 1 Clr 2 3 4 5 6 7 8 Cap Aw 1 Aw 2 7500 K 5600 K 3200 K 0 Gain Black Scene file 1 2 3 Standard Store On air Auto iris F Number Extender Cam select 4 1 15 M black Iris 8 Free Call Preview Centre Range Col Temp Gain Filter 350 7 5 Mounting Plates 3 Usetwoscrewstoattachthemountingplatestothe sides of the hole If desk height is less than 20 mm use two angled p...

Страница 10: ...evel Level Lev dep Var Bars Contour Auto Auto wh Auto blk Point Slope Knee 1 Clr 2 3 4 5 6 7 8 Cap Aw 1 Aw 2 7500 K 5600 K 3200 K 0 Gain Black Scene file 1 2 3 Standard Store On air Auto iris F Number Extender Cam select 4 1 15 M black Iris 8 Free Call Preview Centre Range Col Temp Gain Filter Mounting Plate Mounting Plate Mounting in a 19 inch Rack 1 Remove upper panel by loosening screws and dis...

Страница 11: ...dep Var Bars Contour Auto Auto wh Auto blk Point Slope Knee 1 Clr 2 3 4 5 6 7 8 Cap Aw 1 Aw 2 7500 K 5600 K 3200 K 0 Gain Black Scene file 1 2 3 Standard Store On air Auto iris F Number Extender Cam select 4 1 15 M black Iris 8 Free Call Preview Centre Range Col Temp Gain Filter 19 module rail with mounting strip 19 module rail with mounting strip 3 Use four screws to mount operational control int...

Страница 12: ... Data Subboard This jumper S1 has two positions AB WatchdogOn AC Watchdog Off The Data Subboard is normally delivered with the jumper S1 in position AB Watchdog On User Jumpers With Jumper S4 you can choose between Complete Panel Lock or beneath Gain Field no Panel Lock This Jumper S4 has two positions AB Complete Panel Lock AC Beneath Gain Field no Panel Lock The Data Board is normally delivered ...

Страница 13: ...02 33 2 Technical Manual LDK 4628 Operational Control Panel 11 Replacing the fuses ...

Страница 14: ...400 m 7 875 ft with 14 mm cable Base Station LDK 4501 LDK 200 Triax Cable Maximum Length 2 400 m 7 875 ft with 14 mm cable LDK 23HS mkII with LDK 4482 SuperXPander CABLE TEST AC DC CAM ON ON AIR 0 mains Camera Processing Unit HS mkII Triax Cable Maximum Length 800 m 2 625 ft with 14 mm cable 1000 m 3281 ft with minor performance degradation Base Station LDK 4501 CPU LDK 4058 mkII Clear ND1 4 ND1 1...

Страница 15: ...d camera systems in one chain can be handeld however inamultiplesystemtheloadofaLDK 23 HS mkII is twice the load of a standard camera This configuration is the multiple camera Triax mode The camera is connected to a CPU as in the single camera Triax mode The data bus is looped through from CPU to CPU s Base Stations OCP s and MCP The OCP s Operational Control Panels are used to controlthecamerasan...

Страница 16: ...y on the units during installation Theassignmentnumberofacameraheadconnected to a Base station is automatically set to the number of the Base station to which it is connected The number on the Base station which is connected to the data bus mustbesettothenumberoftheassignedcontrol panel It is important to set a unique number for each Base station OCPgroupasunpredictablecontrolsituations could aris...

Страница 17: ...ector Panel Mains Input Connector Eurostyle 3 pin male 1 Neutral 2 Line 3 Earth Mains input voltage Between 230 Vac and 115 Vac 15 Mains frequency 47 to 63 Hz Fuses 1 A slow 250 Vac X 1 Mains Input Connector Panel view Rear view of OCP X 891 X 890 X 897 X 878 not used Mains input connector X 1 3 2 1 ...

Страница 18: ...el view Data Connectors 9 pin male shielded cable 1 Preview 1A 2 Preview 1B 3 Preview 1C 4 Not used 5 Not used 6 Not used 7 Not used 8 Not used 9 Shield Shield of cable directly to the pin marked shield A 9 pin female cable connector is available under part number 2422 022 06216 The cable hood for this connector is available under part number 2422 021 02467 Preview switch not pressed 1A connected ...

Страница 19: ...ring Variable Saturation Wh clip Blk str Blk str Saw Gamma Flare Contour Var V level Level Lev dep Var Bars Contour Auto Auto wh Auto blk Point Slope Knee 1 Clr 2 3 4 5 6 7 8 Cap Aw 1 Aw 2 7500 K 5600 K 3200 K 0 Gain Black Scene file 1 2 3 Standard Store On air Auto iris F Number Extender Cam select 4 1 15 M black Iris 8 Free Call Preview Centre Range Col Temp Gain Filter 100 00 mm 40 00 mm 58 94 ...

Страница 20: ...18 Technical Manual LDK 4628 Operational Control Panel 02 33 2 ...