background image

 

14 

D

A

B

E

C

Main dimensions:  

 
 
 
 
 
 
 
 
 

 

                                                                                                   Figure 5. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Table 4.  

 

Main dimensions (mm) 

Sign  Description 

Type  

PT80  PT71  PT68  Optimum  PT62 

width 

800  710  680 

680 

620 

depth 

440  440  440 

430 

440 

height 

852  852  762 

640 

762 

chimney connection 

200  200  200 

200 

150 

frame height 

550  550  500 

500 

500 

Содержание PanAqua PA Mini

Страница 1: ......

Страница 2: ...ted and approved by the competent authority is accepted The apparatus is only allowed to be connected to a chimney with identical or larger diameter compared to that of the smoke exit At the connectio...

Страница 3: ...at the top between the firebox and the mantelpiece and a minimum of 5 cm between the firebox and the wall a distance of at least 5 cm must be kept from the upper cone of the firebox it should rather...

Страница 4: ...3 Figure 1 Figure 2...

Страница 5: ...addition to the space visibly required for their motion If the criteria listed are not met the firebox may be seriously damaged and the guarantee is lost No flammable substances are allowed to be use...

Страница 6: ...tain cases return flow can occur in case of not completely closed fireboxes smoke gets into the living space when out of service or when the door is opened In case of inadequate ventilation the firebo...

Страница 7: ...PanTech fireboxes are made of 4 and 5 mm thick and PanAqua fireboxes of 5 mm thick steel plates constituting the firebox together with up to 700oC heat proof glass 2 1 Firebox use Door the firebox is...

Страница 8: ...own by the convection cover therefore little heat is lost in some cases flow is not even started so there is no appropriate heat delivery during operation leading to overload Thereby efficiency is ver...

Страница 9: ...h and their tar content is low Soft wood can only be used for lighting fires Soft wood types birch lime pine poplar and Lombardy poplar burn quicker yield large quantities of ash and their embers cool...

Страница 10: ...8 hours of continuous firing The room should be aired in such a case as high concentrations of the gases released can be injurious to health and can cause aesthetic damage as well External air supply...

Страница 11: ...coal garden and agricultural waste e g twigs corn stalks walnut kernels lacquered parquet broken up or painted lumber etc pellet and other tableted wood fuel combustible mineral fluids petrol diesel...

Страница 12: ...17 15 15 10 13 Flue gas temperature at nominal output C 300 300 300 300 300 283 Efficiency at nominal output 77 77 77 77 73 77 CO emission according to MSZ EN 13229 0 28 0 28 0 28 0 28 0 29 0 28 Mass...

Страница 13: ...ze of filling aperture firebox door Width mm 760 670 640 640 640 640 580 Height mm 480 480 430 430 430 430 430 Total weight kg 182 168 151 151 106 106 127 Recommen ded size of ventilation grids cm2 57...

Страница 14: ...aximum fillup height cm 30 30 25 25 25 Table 3 Standards MSZ EN 13229 2001 Solid fuel fired fireplace inlets including appliances under MSZ EN 13229 2001 A1 2003 with an open fire chamber Requirements...

Страница 15: ...Table 4 Main dimensions mm Sign Description Type PT80 PT71 PT68 Optimum PT62 A width 800 710 680 680 620 B depth 440 440 440 430 440 C height 852 852 762 640 762 D chimney connection 200 200 200 200 1...

Страница 16: ...ini Nominal output kW 15 20 25 24 30 30 40 12 Flue gas temperature C 230 230 230 230 250 270 230 Efficiency 80 80 80 80 80 80 CO emission according to MSZ EN 13229 0 1 0 1 0 1 0 1 0 11 0 11 Mass flow...

Страница 17: ...of filling aperture firebox door Width mm 580 640 670 760 1060 640 Height mm 640 640 510 510 510 640 Total weight kg 174 189 215 209 238 310 141 Exhaust product nominal connection mm 150 200 200 200...

Страница 18: ...d putting into operation of water heating systems MSZ EN 1443 2003 Flue exhaust equipment General requirements MSZ EN 1457 A1 2003 Flue exhaust equipment Ceramic casing tubes Requirements and testing...

Страница 19: ...ng protection in case of excessive burning and or power supply interruption is ensured by a safety cooler circuit Figure 5 Figure 6 A higher efficiency heating system can be produced by installing a b...

Страница 20: ...19 Safety heat exchanger connection diagram with the proposed safety fittings Thermal valve with a Honeywell TS type valve Figure 8...

Страница 21: ...Figure 9 7 Table 7 Main dimensions mm Sign Description Type PAII30Z PAII25Z PAII20Z PAII15Z A width 800 710 680 620 B depth 537 537 537 537 C height 955 955 855 855 D chimney connection 200 200 200 1...

Страница 22: ...PH 110 EVO PH 110 EVO 2D Nominal output KW 14 14 17 17 21 21 Flue gas temperature C 260 290 270 300 260 290 270 300 260 300 270 310 Efficiency h 80 80 80 80 80 80 CO emission according to MSZ EN 13229...

Страница 23: ...70 1120 1070 1120 1170 1170 Size of filling aperture firebox door Width mm 640 640 760 760 1060 1060 Height mm 465 465 465 465 515 515 Total weight kg 180 200 203 225 283 307 Recommended size of venti...

Страница 24: ...nd MSZ EN 13229 2001 A2 2005 testing methods MSZ EN 1443 2003 Flue exhaust equipment General requirements MSZ EN 13384 1 Flue exhaust equipment Thermal and flow dimensioning procedure Fuel consumption...

Страница 25: ...ctions Figure 10 e 11 Table 11 Main dimensions mm Sign Description Type PH110 PH80 PH68 A width 1100 800 680 B depth 569 571 567 C height 1170 1265 1070 1170 1070 1170 D chimney connection 200 200 200...

Страница 26: ...25 Lift door version LD Table Figure 11...

Страница 27: ...tipped out carefully until it stops After applying a glass cleaner place the glass carefully back into vertical position by gently putting it a bit downwards Fasten in with the latch Main dimensions m...

Страница 28: ...5 1 5 1 5 Table 13 Table 14 Overall dimensions Unit PA68E PA80LD PA80E PA100LD PA110E PA130LD Depth mm 555 620 555 620 555 620 Width mm 680 810 800 930 1100 123 0 Height mm 1100 1250 1100 1250 1150 13...

Страница 29: ...tions Figure 12 Tab Table 15 Main dimensions mm Sign Description Type PA68E PA80E PA110E A width 680 800 1100 B depth 575 575 575 C height 1088 1153 1088 1153 1138 1203 D chimney connection 200 200 20...

Страница 30: ...Figure 13 Main dimensions mm Sign Description Type PA80LD PA100LD PA130LD A width 680 800 1100 B depth 575 575 575 C height 1088 1153 1088 1153 1138 1203 D chimney connection 200 200 200 E frame heig...

Страница 31: ...e and fittings No warranty coverage on glues seals ceramic glass and fire clay insert Venue of repairing work falls under this warranty Technical Kft 1103 Bp K r u 16 Tel 3612602290 The mutation of se...

Страница 32: ...ty card for the period required by law Warranty card for the period required by law Date of report WARRANTY SLIP Reported fault Type Reparation method Serial number Date of purchase 201 year month day...

Страница 33: ...nstallation of the fireplace and in case of water jacket type firebox the heating system was assembled by professionals Commencement of the warranty period The warranty period starts on the day when t...