Use Allen wrench to remove
battery compartment tray.

Remove cover by rotating the
cover up at the end over the
battery compartment and
slide out.

Remove rubber seal.

APPENDIX A - ADJUSTING YOUR AUTOFLUSH

®

TO CHANGE ACTIVATION DISTANCE FOR THE OBJECT LOCK SENSOR:

1

Remove battery compartment.

See illustration 2.1.

2

Remove cover.

See illustration 2.2.

3

Replace battery compartment in AutoFlush

®

to activate unit and remove rubber seal.

See illustration 2.3.

4

Press sensor range reset button as indicated in Appendix A. NOTE: the green L.E.D.will flash continuously
when it has an object in view for the seven minute reset period.

5

Stand at desired activation distance.

6

Use provided sensor adjustment tool and turn Sensor Range Adjustment Screw all the way down (count-
er clockwise) and then turn slowly up (clockwise) until green L.E.D.begins to flash.

7

Ensure Object Lock Sensor is not detecting stall door or wall by closing door, stepping out of sensor path
and making sure green L.E.D.is not flashing. If sensor locks onto door or wall, unit will not flush properly.
Shorten activation distance.

8

Remove battery compartment, and replace cover. Replace battery compartment tray to reactivate
AutoFlush

®

unit.

9

After 7 minute start-up sequence, the green L.E.D.will flash only 3 times when a user is in view 
(after a 5 second delay).

1

ON

2

1

ON

2

-

+

Sensor Range

Adjustment Screw

Short

Long

Operation

Features*

Switch 1

24 Hours Flush Off

Switch 2

Alarm Tone Off

Switch 1

24 Hours Flush Off

Switch 2

Alarm Tone On

Switch 1

24 Hours Flush On

Switch 1

24 Hours Flush On

Switch 2

Alarm Tone On

Switch 2

Alarm Tone Off

Sensor Range Reset Button

Courtesy Manual

Flush Button 

(Toilet Model Only)
Allows manual activation 

of flush if needed.

Sensor Range

Adjustment

Use Sensor

Adjustment

Tool

Battery LED 

(Yellow) Flashing LED = Change Batteries

*Trap Seal Protection (24hr flush): 

Ensures fixtures are flushed at least once every 24 hours.  This feature prevents sewer gases

escaping through open trap.  This feature can be turned off by placing switch #1 in the down position.

*Battery Replacement Tone:  

Optional audio tone reinforces yellow LED (change batteries).  This feature can be turned off by

placing switch #2 in the down position.

Object Lock Sensor- 

Detects User or Object

User-In-View LED 

(Green) Flashes 3 Times = User acknowledged & ready to operate.

1

ON

2

1

ON

2

1

ON

2

1

ON

2

TROUBLE SHOOTING GUIDE

PROBLEM

CAUSE

SOLUTION TO PROBLEM

Green L.E.D.(light) flashes 3

times when there are no users

Green L.E.D.(light) flashes 

continuously when Object Lock

Sensor is activated by a user

Yellow L.E.D.(light) flashes

Not enough water to fixture or

too much water to fixture

Valve will not operate

Valve does not shut off

Valve does not flush even after

Sensor Range has been 

adjusted

Front of Object Lock Sensor is covered or Object

Lock Sensor is set too far out,registering the

opposite wall or door as a user

AutoFlush

®

unit is in 7 minute start up mode

(when first activated) or Sensor Range Reset

Button has been depressed

Batteries need replacing

Diaphragm damaged or valve control stop 

improperly adjusted

Object Lock Sensor range set to close to

AutoFlush

®

,batteries are dead,or water supply

is turned off

Dirt or debris preventing diaphragm from func-

tioning properly

Dead batteries

Remove item covering sensor or adjust Object Lock 

Sensor activation distance.(See Appendix A -

Adjusting the AutoFlush)

Green L.E.D.(light) will flash only 3 times 

acknowledging a user is in view after the 7 minute

start up mode

Replace batteries. Use ONLY alkaline batteries

Replace diaphragm and/or adjust valve control stop

Adjust Object Lock Sensor—Replace batteries—Turn 

water on.If the AutoFlush

®

does not begin to function,

call (800) 551-5155 for technical assistance.

Remove dirt or debris,consult valve manufacturer’s 

directions

Replace batteries.

Your AutoFlush

®

unit comes preset from the facto-

ry.If special circumstances require adjustment of
the activation distance, see Appendix A—
Adjusting Your AutoFlush

®

.

The AutoFlush

®

unit has a 7 minute start-up

sequence in which the Object Lock Sensor will
activate the User-In-View green L.E.D. continu-
ously as long as a user or object is in view. After
the start-up sequence is completed and when the
Object Lock Sensor has a user in view, the User-In-
View green L.E.D. will flash 3 times once the user
is in front of the unit for a minimum of 5 seconds.
This  prevents needless flushes when someone
walks by.

ACTIVATION

USER-IN-VIEW L.E.D.  

(Green light flashes 3 times, after 

5 second delay, when a user is in view.  The green light 
flashes constantly when a user is in view during
the 7 minute start up sequence).

OBJECT LOCK SENSOR

(Detects user or object).

 

BATTERY L.E.D.  

(Yellow light flashes 

indicating it is time to replace 
batteries with 4 new “C” cell alkaline batteries).

COURTESY MANUAL FLUSH BUTTON

(Allows manual activation of 
flush when needed—Toilet 
model only).

VISUAL INDICATOR GUIDE

1

ON

2

2.1

2.2

2.3

Spanish and French instructions are available at www.technicalconcepts.com
Instrucciónes en Frances y en Español estaran disponibles en la pagina www.techicalconcepts.com
Les instructions sont disponibles en francais et en espagnol sur notre site web ; www.technicalconcepts.com

Step 2.