Technica Engineering 100Base-T1 SFP Скачать руководство пользователя страница 10

 

 

 

100BASE-T1 MediaConverter NXP 

User Manual  

10 

The Tyco Electronics (TE) Micro Quad Lock System (MQS) is used. 

 

Name 

Picture 

Part Number 

Tyco, MQS Abdeckkappe 2x9 Pol, black 
Alternative 

 

1-967416-1 

1-1355350-1 

Tyco, MQS Buchsengehäuse 2x9 Pol 
Alternative 

 

965778-1 
962108-2 

Tyco crimp contact 

 

928999-1 

Table 1: Parts of black MQS connector 

 

You can use the official Tyco tool for these crimp contacts. A cheap variant is the  

       crimp tool for “PSK” contacts. 

 

 

Pin 

Function 

Pin 

Function 

B12 Volt Input 

10 

Power Ground 

reserved 

11 

reserved 

n.c. 

12 

n.c. 

n.c. 

13 

n.c. 

n.c. 

14 

n.c. 

n.c. 

15 

n.c. 

n.c. 

16 

n.c. 

100BASE-T1 port, negative 

17 

n.c. 

100BASE-T1 port, positive 

18 

n.c. 

Table 2: Pinning of black MQS connector 

 

2.1.2

 

RJ45 Ethernet connectors 

 

There is one RJ45 Standard Ethernet connector for Fast Ethernet (100BASE-TX). 

 

 

 

 

Содержание 100Base-T1 SFP

Страница 1: ...100BASE T1 MEDIACONVERTER NXP Manual Version 2 5 Hardware Version 1 5 USER MANUAL July 2020...

Страница 2: ...or the power supply of Technica Engineering s products 5 1 2 Warranty and Safety Information 6 1 3 RoHS Certificate of Compliance 8 1 4 Scope of Delivery 8 2 HARDWARE INTERFACES 9 2 1 Connectors 9 2 1...

Страница 3: ...00BASE T1 MediaConverter_NXP transmits data frames directly from the physical layer BroadR Reach 100BASE T1 to Fast Ethernet 100BASE TX with constant delay time of 2 0 s 1 1 1 Features 1 port BroadR R...

Страница 4: ...otive onboard power systems correspondingly and can be found in the mentioned norms Should Technica Engineering s products be operated in voltage ranges beyond those specified in the norms which repre...

Страница 5: ...by switching the device off This automatic switch off function is independent of any software function The root cause of excessive temperature in the power supply circuit can eventually be due to a t...

Страница 6: ...nts An automotive like environment includes test setups or test benches in the office laboratory and workshop areas In the test setups the same environmental conditions apply as in vehicle electrical...

Страница 7: ...stallation space This symbol is only valid in the European Union If you wish to discard this product please contact your local authorities or dealer and ask for the correct method of disposal Technica...

Страница 8: ...gineering s 100BASE T1 MediaConverter NXP complies with RoHS Restriction of Hazardous Substances Directive Certificate of Compliance 1 4 Scope of Delivery The delivery includes 1x 100BASE T1 MediaConv...

Страница 9: ...T1 MediaConverter_NXP Figure 2 1 Label of 100BASE T1 MediaConverter_NXP 2 1 1 Black MQS Connector The pinning of the ECU connectors is listed on the label on top of the device as well See FIGURE 2 1 T...

Страница 10: ...of black MQS connector You can use the official Tyco tool for these crimp contacts A cheap variant is the crimp tool for PSK contacts Pin Function Pin Function 1 Battery 12 Volt Input 10 Power Ground...

Страница 11: ...case for the 100BASE T1 Port color Description Green It is lit when there is a linkup on the 100BASE T1 port Yellow It is toggling in alternation with the green LED when there is communication Table...

Страница 12: ...Port is set to Master 100BASE T1 Port is set to Slave 2 ON up OFF down 100BASE T1 Port is set to FullOut 100BASE T1 Port is set to HalfOut Table 4 Configuration of DIP Switches In a 100BASE T1 Link o...

Страница 13: ...e a standard use case of the 100BASE T1 MediaConverter_BCM Figure 4 1 Example for use case MC MediaConverter DUT Device under Test DIP Switch 2 should be always ON DIP Switch 1 is dependent of the DUT...

Страница 14: ...Converter NXP User Manual 14 5 100BASE T1 FILTER The following 100BASE T1 filter is used in the 100BASE T1 MediaConverter_NXP Hardware version 1 0 and following Figure 5 1 100BASE T1 filter for HW v1...

Страница 15: ...segments is limited to 15 meters The difference between the 100BASE T1 MediaConverter_BCM and 100BASE T1 MediaConverter_NXP is the used transceiver for the 100BASE T1 PHY In the beginning of developme...

Страница 16: ...NXP User Manual 16 7 LIST OF FIGURES Figure 1 1 100BASE T1 MediaConverter_NXP 3 Figure 2 1 Label of 100BASE T1 MediaConverter_NXP 9 Figure 4 1 Example for use case 13 Figure 5 1 100BASE T1 filter for...

Страница 17: ...1 2 Extension of warranty and safety 23 03 2020 2 3 All Optical adaption 23 03 2020 2 4 All Small spelling corrections May 2020 2 5 1 1 4 Added information on General Operating and Safety Strategy of...

Страница 18: ...this product please feel free to contact us Technica Engineering GmbH Leopoldstr 236 80807 M nchen Germany Technical support support technica engineering de General information Info technica engineer...

Страница 19: ...ngineering de wp content uploads 2018 06 100base t1 mediaconverter nxp 1600 eu declaration of conformity pdf Eesti K esolevaga deklareerib Technica Engineering GmbH et toode h ivamismoodul 100BASE T1...

Страница 20: ...30 ES Visas ES atitikties deklaracijos tekstas prieinamas iuo internet adresu https technica engineering de wp content uploads 2018 06 100base t1 mediaconverter nxp 1600 eu declaration of conformity...

Страница 21: ...uploads 2018 06 100base t1 mediaconverter nxp 1600 eu declaration of conformity pdf Slovensko Technica Engineering GmbH potrjuje da je izdelek 100BASE T1 MediaConverter NXP TE1600 skladen z irektivo 2...

Отзывы: