background image

7

EG

1. 

Set the          button to DRY. The icon       is displayed. 

2. 

Press the +/- buttons (temperature selection) to set the 
desired temperature (the temperature range is between 
32 °C max. and 10 °C min.). 

DEHUMIDIFYING (DRY)

THE DISPLAY SHOWS THE 

SELECTED TEMPERATURE.

AFTER 5 SECONDS FROM THE 

REQUIRED TEMPERATURE SETTING 

THE DISPLAY WILL SHOW THE ROOM 

TEMPERATURE AGAIN.

l

 

Use DRY operation when you want to reduce the humidity 
in the room.

l

 

Dehumidifying operation is adjusted both by the difference 
between set temperature and air temperature, and by the 
value of relative humidity, detected by the sensor.

l

 

During DRY operation, the fan speed is automatically 
set (Remote control lamp             is ON) to prevent 
overcooling.

l

 

Dry operation is not possible if the indoor temperature is 
10 °C or less.

l

 

When room temperature is above set value, the unit 
operates to dehumidificate so efficient as possible.

l

 

When room temperature is below set value, the unit will 
not stop, it will proceed operating with low power to 
dehumificate and, in small spaces, temperature could 
drop below the set temperature.

NoTE

FAN oNLY

If you want to make air circulate without any temperature 
control, press          button until only the             fan symbol 
appears on the display.

ADJUSTING THE FAN SPEED

AUTOMATIC

Simply set the FAN selector to the             position.The unit 
automatically controls the fan speed when the AUTO mode 
is selected. When the air conditioner starts operating, in 
heating or cooling, the fan speed varies according to the 
thermal load of the room.

MANUAL

If you want to manually adjust speed just set the FAN 
selector as desired. 

High speed

Med. speed

Low speed

A U T O M A T I C   O P E R A T I O N   I N   M U L T I S P L I T 

coNFIGURATIoN

When the air conditioning system configuration is multisplit 
and there is more than one indoor unit connected, the 
automatic mode operates as follows:

- the first unit that switches on the system also decides the 

operation mode (cooling or heating) for all the other units 

that will be switched on after the first one;

- when the system has been switched on in cooling mode 

and one unit is activated in heating mode, an error will 

be signaled for this unit (wrong operating mode). If the 

same unit is switched on in “automatic” mode and the 

desired temperature is lower than the detected ambient 

temperature, the unit will operate in cooling mode, like the 

other units of the system; on the contrary, if the desired 

temperature is higher than the detected one, the unit will 

operate in fan mode;

- when the system has been switched on in heating mode 

and one unit is activated in cooling mode, an error will 

be signaled for this unit (wrong operating mode). If the 

same unit is switched on in “automatic” mode and the 

desired temperature is higher than the detected ambient 

temperature, the unit will operate in heating mode, like the 

other units of the system; on the contrary, if the desired 

temperature is lower than the detected one, the unit will 

operate in fan mode.

NIGHT MODE / ENERGY SAVING

l

  This mode enables you to save energy.

1.

  Set the         or             selector to cool, dry or heat.

2.

  Press the            button.

3.

  The          mark appears on the display. Press the            

button again to release the function.

What does the NIGhT mode mean?

When you select the NIGHT mode, the air conditioner will 
modify automatically the set temperature after 60 minutes. 
This enables you to save energy without sacrificing your 
comfort.

 

OPERATING MODE 

   SET TEMPERATURE CHANGE

 

Heating 

Lowered by 2 °C

 

Cooling and Dry 

Raised by 1 °C

During the NIGHT mode the internal fan speed is 
automatically lowered and reduces the noise. 

NoTA

NoTE

During the high power operation the room temperature 
could not correspond to the set temperature. 

HIGH POWER MODE

When this mode is active the internal fan speed is set 
automatically and the air conditioner operates at the 
maximum power in the selected operating mode (cooling 
or heating).

1.

 Press the                HIGH POWER button.

3.

 The           mark appears on the display. Press the button 

again to release the function..

Содержание SDA8FIA0R5IBA

Страница 1: ...A NOTICE D UTILISATION OPERATING INSTRUCTIONS ISTRUZIONI D USO INSTRUCCIONES DE USO BEDIENUNGSANLEITUNG Split air conditioner system Condizionatore d aria split system Climatiseurs split Split klimage...

Страница 2: ...UBLESHOOTING 10 EXPLANATION AND USE OF THE REMOTE CONTROL UNIT S MICROSWITCHES 14 NOTE PRODUCT INFORMATION If you have problems or questions concerning your Air Conditioner you will need the following...

Страница 3: ...ME OF PARTS AND OPERATION SELECTOR switch 5 6 7 8 9 4 3 10 2 1 NOTA When the unit receives a signal from the remote controller all the three lamps OPERATION TIMER and STANDBY light up for a moment to...

Страница 4: ...he remote control unit and check the settings of the four microswitches as shown below TEMPERATURE SENSOR SELECTOR l Under normal conditions the room temperature is detected and checked by the tempera...

Страница 5: ...THE TIMER IFEEL IFEEL C SENSOR SELECTOR Press this button to modify the active setting for room temperature detection from remote controller to air conditioner and viceversa FAN BUTTON fan speed Fan...

Страница 6: ...to the setting you want During Automatic Operation IFEEL ON the set temperature is understood as perceived one then the system is automatically adjusted not only according to the air temperature but a...

Страница 7: ...es the operation mode cooling or heating for all the other units that will be switched on after the first one when the system has been switched on in cooling mode and one unit is activated in heating...

Страница 8: ...utton to turn the air conditioner off l Wait for the indoor unit to stop operating l Press the ON OFF button again to turn the air conditioner on SETTING THE 1 HOUR TIMER This function causes the unit...

Страница 9: ...e air conditioner is stopped If you want to turn on the air conditioner push the OPERATION selector with a pen to select the desired mode COOL or HEAT OPERATION WITHOUT THE REMOTE CONTROL UNIT The air...

Страница 10: ...ble the air conditioner does not run at all Possible cause 1 Power failure 2 Leakage breaker tripped 3 Operation button is OFF 4 Batteries in remote control unit have run down Remedy 1 Restore power 2...

Страница 11: ...p is closed The system restarts automatically as soon as a correct operating mode is selected Set the outdoor indoor unit refrigerant circuit address see Installation Instructions Select an available...

Страница 12: ...ck that the dip switch SW2 for communication address setting is in the correct position Check that all earth cables are properly connected to every terminal C h e c k t h a t t h e s h i e l d o f t h...

Страница 13: ...cal wiring diagram Check that the sensor is not damaged and if necessary replace it E6 O F F Fan motor error Fan is stopped and flap is closed The system restarts automatically after some seconds Chec...

Страница 14: ...providing this service Disposing of a battery separately avoids possible negative effects on the environment and human health deriving from an inappropriate disposal and enables its components to be...

Страница 15: ...Z I Route d partementale 28 01600 Reyrieux France T l 33 4 74 00 92 92 Fax 33 4 74 00 42 00 Technibel is a trademark of NIBE ENERGY SYSTEM FRANCE...

Отзывы: