background image

8

EG

HOW TO SET THE PRESENT TIME

COOLING

HEATING

2.

Press the SET H button until the present time hour is

displayed.

Press the SET M button until the present time minutes
are displayed. The display will automatically stop
flashing.

1.

Press the button SEL TYPE three times.

The time indication alone flashes.

THE DISPLAY SHOWS THE SELECTED
TEMPERATURE.

AFTER 5 SECONDS FROM THE REQUIRED
TEMPERATURE SETTING THE DISPLAY WILL
SHOW THE ROOM TEMPERATURE AGAIN.

4. Press the FAN button to select the fan speed.

ON

ON

ON

    1    H

    1    H

MIN.

MAX.

A

B

C

C

B

A

27

26

25

24

23
22

21

20
19

AUTOMATIC OPERATION

1

4

3

2

T

E

M

P+

TE

M

P

-

F

L

A

P

I F

EEL

F

IL

T

E

R

S

E

L

T

Y

P

E

SET

H

SET

M

T

IM

E

R

S

E

L

FA

N

M

O

D

E

Verify that the unit is connected to the
main power and the STANDBY lamp is
light up.
1.Set  the MODE selector to COOL

.

2.Press the ON/OFF button and switch the

air condioner ON.

3.Press the TEMP. buttons to set the desired

temperature (the temperature range is
between 32 °C max. and 16 °C min.).

NOTE

1.Set the MODE selector to HEAT

.

2.Press the ON/OFF button and switch the air condioner ON.
3.Press the TEMP. buttons to set the desired temperature (the

temperature range is between 32 °C max. and 16 °C min.).

THE DISPLAY SHOWS THE SELECTED
TEMPERATURE.

AFTER 5 SECONDS FROM THE REQUIRED
TEMPERATURE SETTING THE DISPLAY WILL
SHOW THE ROOM TEMPERATURE AGAIN.

4. Press the FAN button to select the fan speed.

For several minutes after the start of heating operation, the
indoor fan will stop until the indoor heat exchanger coil has
warmed up sufficiently. This is because the COLD DRAFT
PREVENTION SYSTEM is operating. During this period, the
STANDBY lamp remains lit.

NOTE

DEFROSTING OF HEAT EXCHANGER
OUTDOOR UNIT “STANDBY”

When the outdoor temperature is low, frost or ice may appear
on the heat exchanger coil, reducing the heating performance.
When this happens, a microcomputer defrosting system
operates. At the same time, the fan in the indoor unit stops
and the STANDBY lamp remains lit until defrosting is completed.
Heating operation restarts after several minutes. (This interval
will vary slightly depending on the room and outdoor
temperature).

HEATING PERFORMANCE

A heat pump conditioner heats a room by taking heat from
outside air. The heating efficiency will fall off when the outdoor
temperature is very low. If enough heat is not obtained with this
air conditioner, use another heating appliance in conjunction
with it.

1.Set the MODE selector to AUTO

.

2.Press the ON/OFF button and switch the air condioner ON.
3.Press the TEMP. buttons to set the desired temperature (the

temperature range is between 32 °C max. and 16 °C min.).

When this setting is selected, the air conditioner calculates

the difference between the thermostat setting and the room

temperature and automatically switches to the COOL or HEAT

mode as appropriate.

4.Press the FAN selector button to the setting you want.

THE DISPLAY SHOWS THE SELECTED
TEMPERATURE.

AFTER 5 SECONDS FROM THE REQUIRED
TEMPERATURE SETTING THE DISPLAY WILL
SHOW THE ROOM TEMPERATURE AGAIN.

Example of operation diagram in the          (Auto) mode with the set

room temperature at 23°C.

NOTE

T

he air conditioner changes the operation mode (from cool to heat

or vice versa, if one of the following conditions occurs:

ZONE A: changes if the difference between the room temperature

and the temperature set on the remote control unit is at least 3°C..

ZONE B: changes if the difference between the room temperature

and the temperature set on the remote control unit is at least 1°C,

one hour after the compressor stop.

ZONE C: never changes if the difference between the room

temperature and the temperature set on the remote control unit is

no more than 1°C.

Содержание SCDF Series

Страница 1: ...r Condicionado com condensador remoto K Kl li im ma at ti is st ti ik ko o k kl le ei is st tw wn n c cw wr rw wn n m me e s su um mp pu uk kn nw wt th h EG I F D E P COOL DRY FAN COOL DRY HEAT FAN GR OPERATING INSTRUCTIONS ISTRUZIONI D USO NOTICE D UTILISATION BEDIENUNGSANLEITUNG INSTRUCCIONES DE USO INSTRUCÇÕES DE FUNCIONAMENTO O OD DH HL LI IE ES S C CR RH HS SE EW WS S COOL DRY FAN MOVABLE AIR...

Страница 2: ... practice which can result in severe personal injury or death This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage WARNING CAUTION EG COOL DRY FAN COOL DRY HEAT FAN COOLING OUTDOOR TEMPERATURE 46 C D B ROOM TEMPERATURE 32 C D B 23 C W B OUTDOOR TEMPERATURE 19 C D B ROOM TEMPERATURE 19 C D B 14 C W B OPERATING LIMITS HEATING OUTDOOR TEM...

Страница 3: ... exceeding condensate drainage or because of malfunctioning of the condensate drainage system EG The OFF position does not disconnect the power Use the main power switch to turn off power completely WARNING WATER LEVEL ALARM 3 5 Operation button without remote control Push the button to walk through the OFF COOL and HEAT operation modes PRODUCT IDENTIFICATION 10 2 7 11 5 6 1 8 3 4 9 13 4 3 7 5 12 ...

Страница 4: ... max absorbed powers Install a double pole switch protected fuses of the delayed type upstream the electricity wall socket 10A 4 ELECTRICAL REQUIREMENTS INSTALLATION LOCATION Do not install this air conditioner where there are fumes or flammable gases or in an extremely humid space such as a green house Do not install the air conditioner where excessively high heat generating objects are placed Do...

Страница 5: ...x the basket to the wall below the window sill 2 Place the unit in the basket and check that it is levelled INSTALLATION TYPE C USING THE SUPPORT 1 Fix the support guide to the wall below the window sill 2 Insert the support in the handle of outdoor unit and turn the outdoor unit upside down as shown in the picture 3 Place the support and secure it at the edge of the unit using the screws 4 Insert...

Страница 6: ...ER HEAD EG Insert two AAA alkaline batteries of 1 5 V DC making sure that point in the direction marked in the battery compartment The displayed time flashes Press the SEL TYPE button Remote controller is now ready for operation The batteries last about six months Depending on how much you use the remote control unit Remove the batteries if you do not use the remote control unit for more than one ...

Страница 7: ...mer For details refer to paragraphs SETTING THE HOUR and SETTING THE TIMER2 ON OFF BUTTON This button turns the air conditioner ON and OFF TIMER SEL BUTTON Premendo il pulsante sul display viene attivata la procedura per l impostazione del timer Per dettagli vedere esempio REGOLAZIONE DEL TIMER DISPLAY Information is displayed when the remote controller is switched on If switched off only the oper...

Страница 8: ...is low frost or ice may appear on the heat exchanger coil reducing the heating performance When this happens a microcomputer defrosting system operates At the same time the fan in the indoor unit stops and the STANDBY lamp remains lit until defrosting is completed Heating operation restarts after several minutes This interval will vary slightly depending on the room and outdoor temperature HEATING...

Страница 9: ...NIGHT function What does the NIGHT mode mean In this mode the air conditioner will cool or heat the room to the set temperature and then the thermostat will make the unit pause After about 1 hour the air conditioner will automatically reset the set temperature as follows also refer to graphs OPERATING MODE SET TEMPERATURE CHANGE Heating Lowered by 1 C Cooling and Dehumidifying Raised by 1 C When t...

Страница 10: ... SET H button until the designed hour is displayed Press the SET M button until the designed minutes are displayed The display will change automatically back to show the present time after 10 sec 3 Press the ON OFF button to start the air conditioner 4 Press the TIMER SEL button to activate the ON timer B HOW TO SET THE OFF TIME 1 Press the SEL TYPE button twice The OFF and time indications flash ...

Страница 11: ...TDOOR UNIT CASING AND CONDENSING COIL CAUTION INDOOR UNIT TEST OFF ON AIR FILTER The air filter must be cheked at least once every two weeks operation Operation with a dirty filter always causes a lower efficency of the air conditioner and severe product damage The filter is located at the back of the intake grille in the front of the air conditioner and shall be removed from the upper side of the...

Страница 12: ... OR SUPPORT GUIDE KIT FOR OUTDOOR UNIT If you want to utilise the air conditioner in several rooms it is possible to buy varies baskets or support guides for the installation of outdoor unit 2 holes ø 10 200 210 50 2 holes ø 10 100 min 200 SUPPORT GUIDE BASKET ...

Страница 13: ...be damaged Let direct sunlight into the room Use sunshades blind or curtain DO Always try to keep the air filter clean A clogged filter will impair the performance of the unit To prevent conditioned air from escaping keep windows doors and any other openings closed 13 TROUBLESHOOTING Possible cause 1 Air conditioner room sensor defective Remedy 1 Contact service centre Trouble STANDBY and OPERATIO...

Страница 14: ...A ESTERNA UNITÉ EXTÉRIEURE AUßENEINHEITEN UNIDADES EXTERNAS EXWTERIKES MONADES FMO OUTDOOR FAN MOTOR MOTORE ESTERNO VENTOLA MOTEUR DE VENTILATEUR EXTÉRIEUR AUSSENLÜFTERMOTOR MOTOR EXTERIOR DE LATURBINA EXWTERIKOS ANEMISTHRAS FMI INDOOR FAN MOTOR MOTORE INTERNO VENTOLA MOTEUR DE VENTILATEUR INTÉRIEUR INNENLÜFTERMOTOR MOTOR INTERIOR DE LATURBINA ESWTERIKOS ANEMISTHRAS IND ASSY INDICATOR ASSY GRUPPO ...

Страница 15: ...GWP 1975 Zerstreuen Sie R410A in Atmosphäre nicht R410A ist ein fluoriertes Gas abgedeckt durch Kyoto Protokoll mit einem globalen wärmenden Potential GWP 1975 No expulsar R410A a la atmósfera el R410A es un gas fluorado de efecto invernadero cubierto por el protocolo de Kyoto con potencial de calentamiento global GWP 1975 Não exale R410A na atmosfera R410A é um fluorinated gás coberto pelo protoc...

Страница 16: ...S A C Printed in italy R D 28 Reyrieux BP 131 01601 Trévoux CEDEX France Tél 04 74 00 92 92 Fax 04 74 00 42 00 R C S Bourg en Bresse B 759 200 728 ...