Technibel PMERV 5 Скачать руководство пользователя страница 11

11

10 - WIRING DIAGRAM

PMERV  5

230/1/50

M

L

K

J

I

H

G

F

E

D

C

B

A

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

1       2
3       4
5       6

21       22

(01-18)
(01-18)
(01-18)
(01-13)

(01-12)

1

LOAD

+

-

1

(01-12)

R

S

C

XB/6

XA

U

XA

N

XA

PE

XB/10

XA

02

XA

01

XB/13

SD1

XB/8

XA

04

XA

03

XB/12

J1

XB/1

XB/11

F1

2A

E3

E2

BP

HP

XB/2

XB/7

XB/9

T1

230V

24V

XB/14

XB/3

XC/8

XA

08

XA

07

XC/6

XA

05

XC/9

XC/12

XA

06

XC/7

XC/2

A1

A2

XC/1

XC/4

KM2

21

22

XA

XA

XA

21

XA

22

M1

A1

L

N

C1

XB/5

XB/4

M2

KM2

1

2

3

4

5

6

C2

R

L1

(N

)

(M)

W

L

G

P

M

W

G

G

B

BW

RL

MR

WM

RW

R

R

L1

L1

L1

WG

PG

NM

NL

NB

(B)

R

B

B

SD2

SD3

R1

KM2

EV1

Power supply

230V/1/50

XC regulator

connector

XB regulator

connector

Circulating

pump

On/Off

Alarm

Hot/Cold

A1

Pressure control card

C1

M1 capacitor

C2

M2 capacitor

E2

High pressure switch

E3

Low pressure switch

EV1

Electrovalve

F1

Control circuit fuse

J1

Water differential pressure switch

Symbols of the components

Colours of the wires

B

Blue

BW

Blue/White

G

Grey

GN

Grey/Black

L

Purple

M

Brown

MR

Brown/Red

N

Black

NB

Black/Blue

NL

Black/Purple

NM

Black/Brown

P

Pink

PG

Pink/Grey

R

Red

RG

Red/Grey

RL

Red/Purple

RW

Red/White

W

White

WG

White/Grey

WM

White/Brown

KM2

Contactor compressor

M1

Fan 1

M2

Compressor

R1

Anti-freeze resistor

SD1

Water probe

SD2

Heat exchanger temperature probe

SD3

Defrosting condensation temperature probe

T1

Transformer

10 05 648 - 00

9 - PRESSURE CURVES

9.1 - HEATING MODE

4

6

16

10

12

14

8

18

20

17

18

19

20

21

22

25

23

24

45°C
35°C

4

6

16

10

12

14

8

18

20

3.5

4

5

6.5

5.5

6

4.5

45°C
35°C

-5

5

0

10

10

12

14

16

18

-10

20

22

24

15

45°C
35°C
25°C

-5

5

0

10

1.5

2

2.5

3

3.5

-10

4

4.5

5

15

45°C
35°C
25°C

HIGH PRESSURE

LOW PRESSURE

9.2 - COOLING MODE

Low pressure (relative bar)

Outside wet bulb temperature  (

°

C)

Outside wet bulb temperature  (

°

C)

High pressure (relative bar)

Water outlet temperature

Water outlet temperature

HIGH PRESSURE

LOW PRESSURE

Water outlet temperature  (

°

C)

Water outlet temperature  (

°

C)

High pressure (relative bar)

Outdoor temperature

Outdoor temperature

Low pressure (relative bar)

Содержание PMERV 5

Страница 1: ...1 10 11 338 GB 06 April 2004 PMERV 5 AIR COOLED WATER CHILLER HEAT PUMP R 407 C refrigerant INSTALLATION INSTRUCTIONS...

Страница 2: ...ed for the R 407 C fluid 3 The weight of the refrigerant contained in the storage bottle must be checked constantly Do not use it from the moment the remaining weight is less than 10 of the total weig...

Страница 3: ...ect s technical file The personnel responsible for receiving the unit must conduct a visual inspection in order to identify all damage to which the unit may have been subjected during transport refrig...

Страница 4: ...ion The electrical connection conduits must be fixed Use the cable clamps located inside the switch box Class 1 unit The electrical installation must comply with the standards and regulations applicab...

Страница 5: ...anges heating cooling are to be performed with the unit shutdown Remote control off Operating mode 2 1 3 4 PMERV Jumper to be removed The Remote control unit K 60 D 035 Z can perform this function 4 2...

Страница 6: ...2 220 Ohmic value Ohm 24 VAC SUPPLY TRANSFORMER CARTE ELECTRONIQUE A MICROPROCESSEUR CHILLER COMPACT ACTUATORS DIGITAL INPUTS Temperature probe S1 for control Temperature probe S2 for defrosting and p...

Страница 7: ...continue to function for a certain amount of time 150 seconds max PRG mute SEL chiller 5 sec comp x 100 PRG mute SEL chiller the PRG 1 key If during the adjustment procedure no key is pressed for 60 s...

Страница 8: ...s if necessary see table below Remedy the fault Important note any work must be done by qualified experienced person The alarm is cancelled automatically when the fault is cleared NOTE If the circulat...

Страница 9: ...e properly tight and that the hydraulic circuit functions correctly purge of circuits position of valves hydraulic pressure That there are no leaks That the machine is stable That the power cables are...

Страница 10: ...MPORTANT NOTE Before carrying out any work on the machine make sure that it is switched off and that access to it is prevented Any work must be carried out by personnel qualified and authorised to wor...

Страница 11: ...olours of the wires B Blue BW Blue White G Grey GN Grey Black L Purple M Brown MR Brown Red N Black NB Black Blue NL Black Purple NM Black Brown P Pink PG Pink Grey R Red RG Red Grey RL Red Purple RW...

Страница 12: ...eux BP 131 01601 Tr voux CEDEX France Tel 33 4 74 00 92 92 Fax 33 4 74 00 42 00 R C S Bourg en Bresse B 759 200 728 Due to our policy of continuous development our products are liable to modification...

Отзывы: